Cyrus F Cyrus F is a versatile sensor uniquely blending motion, and ambient light together with dual channel dimming. This compact in-fixture controller has a 12-24V DC input voltage range. The device can be configured in wireless mode and UART mode. Device firmware can be updated using OTA (Over-the-Air) after installation.
Cyrus F Table of Contents 1. Features............................................................................................................................................................... 3 2. Specifications .................................................................................................................................................... 3 3. Sensor Specifications..................................................................................................................
Cyrus F 1. 2. Features • Motion, and ambient light sensing • 0-10V dual channel class-2 dimming output for intensity and CCT control • Compact form factor • BLE 5.2 based non-flooding intelligent communication • Zero downtime Over-the-Air (OTA) firmware updates • Supports UART Specifications Electrical Symbol Min. Input Voltage Vin Input Current Typ. Max. Unit Remarks 12 24 Vdc Rated input Voltage Iin 22*1 60*2 mA Output Channel Symbol Min. Max.
Cyrus F Environmental Symbol Min. Ambient Temperature ta Storage Temperature ts Case Temperature tc Relative Humidity RH Typ. Max. Unit -20 50 ºC -20 70 ºC 47.6 Mechanical ºC 85 IP Rating % IP20 Min. Typ. Remarks Indoor use only Max. Unit Remarks Dimensions 29.5x36 mm Diameter x Height Dimensions 1.161x1.417 in Diameter x Height Net Weight 90 g In gram Net Weight 3.17 oz In ounce Remarks 3. Sensor Specifications PIR sensor Min. Typ. Max.
Cyrus F 4. Device Dimensions All dimensions are in mm Case Material: V0 PC plastic 5.
Cyrus F 6.
Cyrus F 7. Wiring Diagram 1.
Cyrus F 1b) Powering the Cyrus F via powerpack Cyrus F (Top View) Set the output channel mode of the Cyrus F as ‘single channel’ in the mobile application Design Options Cyrus F (Top 8
Cyrus F 8. Installation Create a hole of diameter 25mm (0.
Cyrus F 9. Warning 1. To prevent the device from any defect, please handle and store it with care. 2. Do not store in very humid location or at extreme temperature. 3. Do not open or disassemble the product. 4. Observe the correct polarity of output terminal 5. Avoid input voltage exceeds the maximum rating, which will cause damage to the circuit and result in malfunction. 6. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 10.
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Cyrus F Version 1.