Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt Sensor Node - User Manual WISENMESHNET® L-Series Omni Tilt Sensor Node User Manual Model: 6305 Wuxi Wisen Innovation Co., Ltd. November 2019 www.wisencn.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt Sensor Node - User Manual Revision History and Clarification Rev. Issue Date Revisions V1.0 01/11/2019 1 Issue st Written By Revised By Xiaoyan Huang Dr. Yan Wu Document Definition: It defines the specifications (i.e.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt Sensor Node - User Manual Table of Contents 1. Product Introduction................................................................................................................................................... - 4 2. System Structure Layout ............................................................................................................................................. - 5 3. Node & Radio Features ....................
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt Sensor Node - User Manual 1. Product Introduction ® The WISENMESHNET Omni Tilt Sensor Node is one of the key products in our patented ® ® WISENMESHNET geotechnical safety monitoring system. Working together with the WISENMESHNET gateway product and node products, it intelligently delivers the real-time tilt deformation of a structure to the information centre.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt Sensor Node - User Manual 2. System Structure Layout Figure 2. System Structure Layout. www.wisencn.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt Sensor Node - User Manual 3. Node & Radio Features Node Features: Basics Battery Power Qty. x 1 (3.6V Lithium primary D-Cell ER34615) Accuracy Stop Voltage 2.7VDC Mesh Stop Voltage 2.1VDC Battery Connection Standard Aluminium Battery Holder Working Current (DC) Max. 65mA (Typ. 50mA) Local Storage Min. 450 Messages during Meshing LxWxH 80 x 75 x 57mm Weight 0.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt Sensor Node - User Manual Radio Band 902-928MHz Central Frequency (Default) 905/910/915/920/925MHz Default Transmit Power 14dBm Receive Sensitivity -112dBm Bandwidth 500kHz Transmission Speed 19.2kb/s No. of Mesh Hop* 6 Hops Supported Sampling Interval 1-60mins Mesh Antenna Omni-directional (20cm in length) or Customised Antenna Connector SMA (M) Antenna Description st st * E.g.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt Sensor Node - User Manual 4. Terminologies Figure 3. Omni Tilt Sensor Node Internal Configuration Terminologies, where: www.wisencn.com No. Terminology 1 Mesh Antenna 2 ER34615 3.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt Sensor Node - User Manual 5. Operation Procedures 5.1.System Deployment Notifications 1) Location: The deployment location of a Omni Tilt Sensor Node is usually determined by the desired monitoring or inspection location; 2) Before any Omni Tilt Sensor Node is switched on, a gateway must be deployed, powered on and proven to be working properly.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt Sensor Node - User Manual 5.3.Deployment Procedures 1) Open the box: Take the node out of the package and open its lid; 2) Insert Battery: By default, a node does not contain a D-Cell battery. Therefore the battery needs to be inserted.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt Sensor Node - User Manual carry out investigation using the following two stage procedure: A. Remote Inspection of historical data, to identify the following: a) Whether the heart-beat message has been sent back successfully at each time interval; b) Whether the battery voltage is too low, if yes, please change the battery unit; c) Whether the signal strength has become significantly weaker than it was previously.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt Sensor Node - User Manual 8. Safety and Warning Warning: Please read the following instructions carefully. 1)Operation Safety Before taking any action, please read all the information provided carefully, and keep the guidance documents safe; Ensure that any procedures and installations are correctly carried out. The case and any mountings should be grounded where practicable.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt Sensor Node - User Manual 9. Contact - Wuxi Wisen Innovation Co., Ltd.: www.wisencn.com - Email: marketing@wisencn.com www.wisencn.
Wisen Innovation Technical Doc. No.2019 WISENMESHNET® L-Series Omni Tilt & Distance Sensor Node - User Manual FCC Warning - This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.