Wireless TENS/EMS RS-18 Remote Electrical Stimulator Instruction Manual M_KMN10530 Rev.1.0 2022.02.
Wireless TENS/EMS RS-18 Instruction Manual Table of Content Introduction ....................................................................................................................... 3 Indication for Use ............................................................................................................... 3 Symbols and Glossary ........................................................................................................ 5 Warnings & Cautions....................................
Wireless TENS/EMS RS-18 Instruction Manual Introduction “Wireless TENS/EMS” RS-18 is an Electrical Stimulator designed and intended for TENS and EMS for the use of alleviate cutaneous pain and improve muscle performance and recovery in the manner of economical and non-pharmacological pain relieve method. EMS is a technique that stimulate nonvoluntary muscular contractions in order to strengthen, enhance endurance, recovery and re-educate atrophied muscles.
Wireless TENS/EMS RS-18 Instruction Manual back and feet. Indications are for the following conditions: - Sore pain - Acute pain - Chronic pain - Post-operative - Post trauma - Muscle Strained - Arthritis - Menstrual The EMS function of RS-18 delivers electric impulses to the motor neuros in muscle fibers to achieve muscle training that include but are not limited to the purposed as followed.
Wireless TENS/EMS RS-18 Instruction Manual Symbols and Glossary Manufacturer Authorized representative in the European Community Importer Distributor Date of manufacture Serial number Consult instructions for use Caution Refer to instruction manual/booklet WEEE wheeled bin European Conformity mark Notified Bodies: DNV GL Stand By Ingress Protection Rating Type BF applied part Medical device Unique Device Identifier 5
Wireless TENS/EMS RS-18 Instruction Manual Warnings & Cautions Usage • Do not use this device if you are, having any cardiac monitors, pacemaker, or ECG alarms. • Do not use this device while taking shower or bath. • Do not use this device while sleeping. • Do not use this device while driving. • Do not use this device in an oxygen-rich atmosphere. • Do not use this device within short wave or unshielded microwave devices as this could alter the current generated by the stimulator.
Wireless TENS/EMS RS-18 Instruction Manual Overview Kit Components Remote Stimulation Pods Electrode Lead wire USB Type C Charge Cable Butterfly Electrode Round Electrodes 7
Wireless TENS/EMS RS-18 Instruction Manual 8
Wireless TENS/EMS RS-18 Instruction Manual Using Instruction Prepare and Setup If you are using new electrode or would like to replace the old hydrogel. Please following 2 steps to implement it. 1. Carefully remote the blue protective film of new hydrogel Note: dispose the blue protective film and should not use it for electrodes storage. 2. Place the gel pads according to the engrafted shape on electrode and remove the second protective film with care.
Wireless TENS/EMS RS-18 Instruction Manual 4. Plug the lead wire type c in to the Pod(s) and attach the lead wire heads to single pad electrodes. 5. Place the Pod(s) on the butterfly electrode. Note: Make sure all magnetic buttons are securely attached with electrodes before starting the treatment program.
Wireless TENS/EMS RS-18 Instruction Manual Start a Program with Remote and Pods 1. Press and hold the 2. Press and hold the button of Remote for 2 seconds to switch it on. button at side of the Pod(s) for 3 seconds to switch it on. The LED indicator should light blue. 2s Note: Blue light means Pod connected to the Remote. 3. Use the button of the Remote to choose treatment type. Then Press the 4. Press the 3s button to enter to list of treatment programs.
Wireless TENS/EMS RS-18 Instruction Manual to remove the program from “My Favorite” list. The red will become white again to indicate remove successful. Ready Status (No Countdown) 6. Press the button to start the program. Start countdown (Program started) 7. Use 8. Press the button to adjust the intensity of focused channel and press button to pause or continue the current program. Timer blinking is pause status 12 to select channel.
Wireless TENS/EMS RS-18 Instruction Manual 9. Hold the button or button any time for 3 seconds to STOP the program manually. or 3s Note: Turn off Remote control or Pods to disconnect the connection. Change the Synchronization mode The intensity adjustment of output channels can be linked together or separated. For change the Synchronization mode, just simply use the to pause the program and press to switch mod. - Total sync: All channels intensity are synchronizing.
Wireless TENS/EMS RS-18 Instruction Manual Start a Program with Pods only (offline) 1. Hold the button for 3 seconds to turn the Pod(s) on. The blinking green LED indicates the pod(s) is not connect to remote and ready for output standalone. 3s 2. Press the button to start the program and the LED will stop blinking.
Wireless TENS/EMS RS-18 Instruction Manual Charge the device 1. Stop the program first. 2. Turn off Remote Control and Pod(s) by pressing for 3 seconds. 3. Connect the Type C USB charging cable in the USB Type C port of Remote or Pod(s) 4. Connect the Type A USB connector of charging cable to any international certificated 5V USB adaptor. Remote control & Pod should be charged individually. Once fully charge, the Remote control will show and stop the icon animation.
Wireless TENS/EMS RS-18 Instruction Manual Programs Programs description and recommendations Always start with the lowest intensity and progressively increase the level of intensity until you feel a "tingling" feeling when utilizing any of the six (6) programs for pain treatment. Each program is unique, and as a result, each experience is unique. You can begin by trying all six (6) programs and then selecting the one that seems most comfortable to you.
Wireless TENS/EMS RS-18 Instruction Manual Any of the 6 programs can be utilized for electrical muscle stimulation (EMS). The purpose is to develop a muscle contraction before releasing it. All six programs will cause contractions, although the rate and length of the contractions will differ. For a warm-up, start slowly and with modest intensity levels (5-10 min). As you progress, increase the intensity level and treatment time.
Wireless TENS/EMS RS-18 Instruction Manual muscles. All six programs will cause tingling from electrical pulses, although the rate and length of the tingling will differ. As you progress with any of the program, increase the intensity level and treatment time if you desire. Use the device on a regular basis or for extended periods of time to receive the benefits of muscle relaxation.
Wireless TENS/EMS RS-18 Instruction Manual Electrodes Placement TENS electrodes placement 19
Wireless TENS/EMS RS-18 Instruction Manual EMS electrodes placement 20
Wireless TENS/EMS RS-18 Instruction Manual Maintenance & Storage Remote, Pods and Accessories, expected life Your device doesn't need to be calibrated or tested on a regular basis. Prior to distribution, each stimulator is thoroughly tested. Under typical circumstances, its properties do not change. If any elements of your stimulator appear to be worn or damaged, please stop using it and contact the manufacturer's designated and authorized customer service center for an upgrade.
Wireless TENS/EMS RS-18 Instruction Manual built-in battery by force. Batteries have a limited lifespan, ranging from 300 to 450 cycles. When not in frequent usage, charge the system every three months to extend the battery life. Note: Once device and pod(s) are fully charged, they can provide treatment for: • Remote: 8-10 hours (about 90 treatments) • Pod(s): 3-5 hours (about 16 ~ 32 treatments) Warning! - Please only use the IEC Class II USB power adapter to charge the device.
Wireless TENS/EMS RS-18 Instruction Manual Troubleshooting Remote & Pods Problem Possible Cause Solution Display does not Low battery Charge battery Electrodes dried out, lost the Replace with new electrode come on Weak stimulation adhesiveness thus have no adequate with loaded connection with the skin batteries Electrode placement Make sure the electrodes are placing at least 5 cm(2 inches) apart on the body Poor electrode contact Reapply electrodes, place firmly.
Wireless TENS/EMS RS-18 Instruction Manual Output description of the programs Settings and Electrodes positioning A. Check that all the settings are Stimulation is not correct and ensure the producing the electrodes are positioned usual sensation properly B. Change the positioning of the electrodes slightly NOTE: If your device appears to be malfunctioning for any reason other than those listed above, please contact manufacturer or authorized distributor customer support.
Wireless TENS/EMS RS-18 Instruction Manual Technical Specifications RS-18 Remote Controller Battery: Lithium Polymer (LiPo) rechargeable 3.7 V, 210 mAh (~5-6 hours of continuous stimulation n average parameters Charging Input: 5V/0.25A C RF Data: 2.4GHz Radio Frequency, auto-pairing, 10m transmission range Device Dimensions: 120mm [4.73"] x 40mm [1.58"] x 12.5mm [0.49"] Device Weight: 44.
Wireless TENS/EMS RS-18 Instruction Manual Information about Electromagnetic Compatibility The RS-18TENS/EMS Remote Control and Pod(s) are intended for use in typical surroundings that have been authorized according to the EN/IEC 60601-1-2:2014+A1:2020 EMC safety standard. This device meets the CISPR standard, which means that radio frequency (RF) emissions are unlikely to cause interference with surrounding electronic equipment (radios, computers, telephones, etc.).
Wireless TENS/EMS RS-18 Instruction Manual 80% AM at 1 kHz IEC 61000-4- PFMF 8:2009 30 A/m 50 Hz or 60 Hz IEC 61000-4- Voltage dips Voltage Dips: 11:2004 & voltage 1) 0% UT; 0.
Wireless TENS/EMS RS-18 Instruction Manual FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Wireless TENS/EMS RS-18 Instruction Manual Warranty Only if accompanied by evidence of purchase is this guarantee applicable. This promise has no bearing on your legal rights. Your RS-18 stimulator comes with a 3-year warranty from the date of purchase (proof of purchase is required). The device and the pod(s) are covered by the warranty (hardware and labor), but not the cables, battery, or electrodes.
Wireless TENS/EMS RS-18 Instruction Manual Manufacturer & After-Sale Service Manufacturer: ZMI Electronics Ltd. 6F-1, No. 286-4, Shin Ya Road, Kaohsiung, 806, Taiwan, R.O.C. Telephone: +886-7-815-0053 Fax: +886-7-815-0057 E-mail: mail@zmi-electronics.com Authorized Representative in the European Union: Sunsam Finance AB Industrigatan 4B 2TR, SE-11246 Stockholm, Sweden Phone: +46-7031-57072 E-mail: info@sunsam.