FCCUM99725 March 15, 2000 Rev - USERS MANUAL FOR THE RAPID SCORING SYSTEM (RSS) Prepared by: 35 Hill Ave. Fort Walton Beach, FL 32548 (850) 244-2332 Email: www.gomicrosystems.
FCCUM99725 March 15, 2000 Rev - TABLE OF CONTENTS Paragraph 1.0 2.0 2.1 2.2 2.3 2.4 2.5 2.
FCCUM99725 March 15, 2000 Rev - 1.0 SCOPE. This document provides information on the setup and operation of the Rapid Scoring System (RSS). 2.0 System Overview. The RSS consists of a single base station, thirty hand held remote interactive modules and a software package which executes on a personal computer (PC) with a Windows95/98 operating system. The software package will also run on a Macintosh PC.
FCCUM99725 March 15, 2000 Rev - 2.1 Base Station Description. The base station controls message traffic flow between the PC and the remote units. Note that the base station is a modified version of the remote. An RS232 interface, Alternating Current (AC) wall adapter and a different software package are the only differences between the base station and remote units. The Liquid Crystal Display (LCD) display and keypad are used for diagnostic test and status display on the base station.
FCCUM99725 March 15, 2000 Rev - power switch will turn the unit off. The base station will display connection status to the PC RS-232 link and status of the RF links, on the PC display, indicated by a flashing circle for each remote which is responding to the base station. This base unit display is shown in Figure 3. RSSM Connection: ACTIVE Remote Connections Active: 20 Figure 3. Base Station Display 2.3 Remote Interactive Module Description.
FCCUM99725 March 15, 2000 Rev - Figure 4. Remote Features KEY Power F1 F2 S1-S5 Backspace Flag up arrow right arrow down arrow left arrow enter Table I.
FCCUM99725 March 15, 2000 Rev - To turn the unit on, press the power key. To turn the unit off, press the power key again. Note that during operation the power off function is disabled until the allotted time has elapsed or enabled by the base station. 2.4 Remote Operation. The remote units operate in concert with the base station, therefore the base station must be powered on and communication established with the server prior to remote activation.
FCCUM99725 March 15, 2000 Rev - Figure 5. Battery Charger 2.6 Battery Pack Replacement. In the event that a battery pack will not remain charged and needs replacement then refer to Figure 6. Place the remote on a flat surface with the display face down exposing the battery pack compartment on the rear of the remote. Remove the battery cover screw with a cross tip screw driver. Press down on the battery pack connector clip on the pack in the unit.
FCCUM99725 March 15, 2000 Rev - Figure 6.