User's Manual

AIRcable User Manual
AIRcable Serial
Model 1302
Wireless Bluetooth to Serial Adapter
User Guide
Rev 0.95
December 7, 2004
Thank you for purchasing an AIRcable. Your satisfaction is very important to us, so please read this guide
before installing your AIRcable modules. We’d appreciate your feedback.
For more information and instructions or for support please visit our website at http://www.aircable.net
The AIRcable product is a Bluetooth to serial adapter for cable replacement functions with user accessible
command line for configuration. The AIRcable product is Bluetooth 1.1 certified.
A
IRcable modules are intelligent and run firmware-based onboard Bluetooth connection software. There is
no need to install and configure extra software to establish a wireless connection. Because the AIRcable is
designed to replace physical connections, you can run the same software that would support a physical
cable.
Each module has a button accessible through a hole in the device which is used to pair two modules to become a point-to-point
Wireless Cable™”. During this pairing process, make sure no other Bluetooth device is discoverable within range (approx. 10 meters).
Each module has one power LED (green) which shows that the firmware is running correctly and a connection LED (blue) that shows
the status of a connection. The connection LED is on solid if a connection to another device is active. Otherwise it is blinking or it is off.
The AIRcable Serial is fully Bluetooth 1.1 certified and is compatible with all other Bluetooth 1.1 compatible devices. The AIRcable
Serial is compilant with RS-232 serial industrial standard EIA-232-E. There are two different versions available: The DTE has a Sub-D 9
pin female connector and the DCE has a Sub-D 9 pin male adapter.
The AIRcable Serial supports all modem control signals, including DTR, DSR, and DCD. Data flow control is implemented using
RTS/CTS handshake. Data mode by default is 8 bit, no parity, one stop bit.
NOTE: Because the devices implement hardware handshake, the
RTS/CTS lines have to be connected
or it
must be switched
off
. If your device does not support hardware handshake you must switch off hardware handshake with the 4th switch on the AIRcable
switch (down) in order for the AIRcable Serial to work properly.
Pin 9 can also be used for powering the AIRcable Serial module. Apply 5-15V DC, plus to pin 9, GND is pin 5 instead of using an
external power adapter.
Pa
g
e 1 of 7AIRcable User Manual

Summary of content (7 pages)