LED Utility Light with motion sensor ITM. / ART. 688836 Model: LM55811 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For assistance with assembly or installation, parts and customer service, call us at 1-866-294-9244 (English), Mon to Fri 8 AM to 5PM Pacific Time, email us at info@winplususa.com 820 South Wanamaker Ave., Ontario, CA 91761, USA www.winplus.
This product is splash proof, suitable for use in home, office, warehouse, workshop, garage and covered wet locations (e.g. covered patios, covered porches, etc.). It is IP65 rated, which means it is protected against dust ingress and is able to withstand splashed water from any direction (does not include being fully submersed in water or deep snow). This product is ideal for lighting in wet areas, such as patio awnings and covered decks. it is also dust and wind proof.
Package Contents: Please layout all parts and read the instructions prior to installation. 1 x LED Utility Light with 1.
Product Specifications: 1. Operating Voltage: 120V ac, 60 Hz 2. Wattage: 48 W / Stand-by mode: 1.5 W 3. Light Output: 3800 Lm 4. Color Temperature: 4000K 5. LED Life Cycles: up to 50,000 hrs 6. Dimensions: 126 cm / 49.4 in (L) x 12.7 cm / 5 in (W) x 8.8 cm / 3.46 in (H) 7. Weight: 2.6kg / 5.7lb 8. Waterproof rating: IP 65 9.
2 3 2. Wear safety glasses before drilling pilot holes. Drill two 5/64 inch / 2 mm diameter pilot holes. 4 3. Screw in the self-tapping screw hook until only the curved eye is visible, no screw threads should be showing. Repeat for another hook. 5 4c 4a 4b 4a. Determine desired hanging height, 5. Clip mounting brackets onto the slip wire hanging hook through the chain. lighting fixture. 4b. Insert the hanging hook into the openings of mounting bracket. Repeat for another mounting bracket. 4c.
Ceiling flush mount: 1 Final installed illustration 2 2. Wear safety glasses before drilling pilot holes. Drill two 5/64 inch / 2 mm diameter pilot holes. 4 4. Clip mounting brackets onto the lighting fixture. 6 1. Select a suitable mounting location, and make sure the wooden surface is suitable for supporting the lighting fixture. Use the measuring template to mark the hook locations on mounting surface. 3 3. Screw on the mounting bracket with wood screws provided.
Ceiling hanging with hooks: 1 Final installed illustration 2 1. Select a suitable mounting location, and make sure the wooden surface is suitable for supporting the lighting fixture. Use the measuring template to mark the hook locations on mounting surface. 3 2. Wear safety glasses before drilling pilot holes. Drill two 5/64 inch / 2 mm diameter pilot holes. 4 3. Screw in the self-tapping screw hook until only the curved eye is visible, no screw threads should be showing. Repeat for another hook.
DIP switch control Setting and Operation: Unplug and allow to cool before changing the control setting. By choosing the setting of DIP switch control, you can use the lighting fixture in different locations. Please refer to the following instructions for choosing the DIP switch control setting. CAUTION: Unplug the power cord from electrical outlet before adjusting the DIP switch control setting.
Definition of the each DIP switch control Setting: Switches 1 & 2: Sensor Detection Distance Sensor Detection Distance is the detection area of the smart sensor. You can set the distance from 3 m / 9.8 ft, 5 m / 16.4 ft, 8 m / 26.2 ft, or 10 m / 33 ft. You may refer to the table below for the height of installation based on 10M setting. Height (H) Sensing Distance (D) 2.5 m / 8.2 ft 7 m / 23 ft - 8 m / 26.2 ft 3.0 m / 9.8 ft 8 m / 26.2 ft - 10 m / 32.
Refer to switches 7 & 8 setting for dim level setting. Switches 5 & 6: Light Sensor Auto Off Light Sensor Auto Off refers to the ambient light level to keep lighting fixture off during the day time regardless any movement. For example, if you set to 10 lux, when the ambient light is above 10 lux, the lighting fixture will be turned OFF even there is motion detected around. When the ambient light is below 10 lux and there is motion detected by the sensor, the lighting fixture will be ON.
You can select “OFF” if you want to have the lighting fixture be turned ON all the time. By selecting this mode, light sensor function will be disabled. After choosing the desired DIP switch control setting, please put back the diffuser (cover) properly by closing all of the retaining clips and screws, to ensure the product remains water proof and dust proof.
Covered Boat Dock: 1 & 2 Distance: 10 m / 33 ft 3 & 4 Time Dim: 10 min 5 & 6 Light Sensor Auto Off: 50 lux 7 & 8 Dim Level: 30% 9 & 10 Motion Sensor Auto Off: 30 min Indoor Parking Lots / Always On: 1 & 2 Distance: 10 m / 33 ft 3 & 4 Time Dim: 5 min 5 & 6 Light Sensor Auto Off: Off 7 & 8 Dim Level: 30% 9 & 10 Motion Sensor Auto Off: Off By selecting this mode, the light will be turned ON all the time. When there is no movement within 5 min, the light will be dimmed to 30%.
Other accessories: The lighting fixture is provided with a plastic cap and a cable bushing. Always refer to a qualified electrician if re-wiring of power cable is required. After re-wiring, plastic cap is used for covering the original opening for power cable, and the cable bushing is used for output of power cable / hardwire.
Warranty: Winplus North America Limited warranty Winplus North America warrants, to the original purchaser, that its products are free from defects in material and workmanship for 1 year from the date of original purchase. Where permitted by law, Winplus North America’s liability shall be limited to that set forth in this limited express warranty.
NOTE: Toll Free # is for North America Customers ONLY. See Customer service section for customer contact numbers for other regions/offices. For customer service and technical support, please call us at 1.866.294.9244 or email us at customercare@winplususa.com. If at that time it is determined that a replacement unit is needed, the support representative will issue a Return Authorization and instruct on how to get a new unit.
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.
Category II) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.