RFID Reader Product Introduction z z z z z z HYR830 adopts Impinj R2000 module, maximum power output is 30dBm. 4 RP TNC ports, with an 7dBi circular polarized antenna, reading distance can reach 10 meters. Reading speed is 400 tags/sec. 8 LED lights, real-time display working status. Many external ports, Including network interface, RS232、GPIO_IN*4、 GPIO_OUT*4、RS485、wiegand、CAN、USB, can meet different client’s requirement.
RFID Reader z User can read and write the tag, and also kill and lock the tag.
RFID Reader Picture1 Front view
RFID Reader External Interface
RFID Reader DB15 Interface definition S/N Item Technical data Unit Pin Signal name Signal direction Function/compatibility Remark description 1 GPIO2 Output Optical isolation 2 GPIO3 Output Optical isolation 3 GPIO8 Input Optical isolation 4 GPIO6 Input Optical isolation 5 WIEGAND1 Output WIEGAND 6 485A Bidirection RS485 7 GPIO1 Output Optical isolation 8 GPIO4 Output Optical isolation 9 GPIO5 Input Optical isolation 10 WIEGAND0 Output WIEGAND port 11 485B
RFID Reader Demo User Guide The Demo software user manual is used for HYM730/HYM740/HYM750 serial modules and HYR810/HYR820/HYR830 series readers; Support Chinese and English language; Support RJ45 connecting. Adopt TCP long connection method, slave computer as TCP server, host computer demo software as the TCP client side. (Notice: RJ45 connecting only for HYR830 reader) Support RS232 connecting, baud rate 115200, 1 bit for start, 1 bit for stop, 8 bits for data. 1.
RFID Reader 2.1 Etherrnet connecttion setting Default IP P address of the t reader is 1192.168.1.10. If connectin ng in Ethernett (RJ45), pleaase set IP adddress of PC att same range, such as 192.168.1.100. Before conneccting, make su ure IP addresss of PC could d be passed att Ping operatiion. Connectioons are displaayed with diff fferent prefix. If connecting g with RJ45, type ‘NET’+ +’IP’ at the dropp-down box of o port. For exam mple, connect to t 192.168.1..10, type ‘NE ET192.168.1.
RFID Reader Picture 4 RS232 port connection 3. Single inventory operation Single inventory operation is in ‘singe ask’ and ‘single answer’ method of reading. Each inventory will result an acknowledgement frame. In each single inventory, only one tag’s EPC data could be gotten. Single inventory mode supports to inventory tag function at any length EPC code. At workspace area, it could display EPC code, Inventory times, RSSI for each tag, as below picture.
RFID Reader Picture 5 Single inventory mode 4. Multiple inventory operation Below picture is for multiple inventory mode. Inventory times are non-limited. At information area, it will display Inventory speed, time and tag numbers. Click ‘off-line clean’, it will launch the function. If a tag is not read in 4 seconds, the marked color of the tag will turn grey, if over 8 seconds, the tag will be cleared from workspace.
RFID Reader Picture 6 Multiple inventory mode 5. RF output power setting TX power setting is in basic settings section, below picture is for TX power setting. Picture 7 RF output power setting The TX power range is 5-30dBm, with 1dBm stepping up. ‘Set’ the picked power, and then ‘get’ for checking the result. Choose "save", the setting will be kept after power off. 6. Region setting Region setting is in basic settings section, as below picture.
RFID Reader Region setting includes China1 area (840.625MHz~844.375MHz), China2 area (920.625MHz~924.375MHz), Europe area (865.7MHz~867.5 MHz), USA area (902MHz~928MHz), Korea and Japan area. Choose the frequency band at your area, and then click ‘set’, ‘get’ is to check the current band you have chosen. Choose "save", the setting will be kept after power off. 7. Frequency hopping setting Frequency hopping setting is in basic settings as below picture.
RFID Reader Picture 11 Temperature information Click ‘get’ to see the working temperature information. For normally, the temperature range is between -40 – 85 degree Celsius. When the “temperature protect” is activated (the default is turn on), once the temperat ure is over 65℃, the rate of inventory would fell by 50%; If the temperature is over 85℃, the reader-module would stop working automatically, and it would back to work again only the temperature below 85℃.
RFID Reader Picture 14 Multiple inventory Delay time setting The setting is for module waiting time after one inventory cycle during the multiple inventory working. This is only applied for single port module. Default value is 0 during multiple inventory. At such case, the module will be working at full load, while the module temperature will be higher. 13. Antenna working and interval time setting Antenna working and interval time setting is in Basic Setting, as below picture.
RFID Reader Click ‘Ring’, you will hear the alarm from the reader. 15. GPIO setting GPIO setting is in Basic Setting as below picture. Picture 17 GPIO setting Notice: HYM series modules only have 3 output IO ports (GPIO1, GPIO2 and GPIO3). HYM830 reader has 4 output IO ports (GPIO1, GPIO2, GPIO3, GPIO4), and 4 input IO ports (GPIO5, GPIO6, GPIO7, GPIO8) The picked output IO ports will output high level, otherwise will output low level.
RFID Reader 18. Q setting In Advanced Settings, below is the picture of Q setting. Picture 20 Q setting There are two ways of dynamic Q and static Q. Dynamic Q is recommended, as it could automatically adjust the Q value to achieve most fast inventory. 19. Single inventory timeout setting In Advanced Settings section, below is the picture for single inventory timeout setting Picture 21 Single inventory timeout setting This function is only for single inventory.
RFID Reader In Tag Operate section, below is the picture for tag reading/writing setting Picture 23 Tag reading and writing setting Memory Bank is data area of the tag, which includes RFU, EPC, TID and USR.RFU is for password zone of the tag, including Access Password (AccPwd) and Kill Password (Killpwd). EPC is the ID number of the tag, usually at 12 bytes. TID is the worldwide sole ID code, and includes the information of tag IC company.
RFID Reader enter ‘tag operate’ interface, then you can operate. 23. Tag Kill setting In Tag Operate section, below is the picture for Tag Kill setting. Picture 25 Tag kill setting It is supported by ISO18000-6C protocol the reader could kill the tags permanently. Please caution the killed tag could not be usable. Tag Kill setting is usually operated with filter operation, which means you can kill the picked EPC tags, and avoid killing un-picked tags.
RFID Reader 25.
www.winnix.net FCC Caution Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.