This .pdf document is bookmarked Operating Instructions & Service Parts Manual COLD FRONT TM Atomized Cooling Fan Model WACF-3037 #28900 MADE IN THE U.S.A. WILTON 427 New Sanford Road LaVergne, Tennessee 37086 Ph.: 800-274-6848 www.wiltontools.com Manual No.
1.0 IMPORTANT SAFETY INSTRUCTIONS WARNING – To reduce risk of fire, electric shock, or injury: 1. Read and understand all warnings posted on the machine and in this manual. Failure to comply with all of these warnings may cause serious injury. 2. Do not use this cooling fan for other than its intended use. 3. Replace warning labels if they become obscured or removed. 4. Keep ground or floor around the machine uncluttered and free of scrap material, oil and grease. Wear non-slip footwear. 5.
2.0 Table of contents Section Page 1.0 IMPORTANT SAFETY INSTRUCTIONS ....................................................................................................... 2 2.0 Table of contents ............................................................................................................................................ 3 3.0 About this machine and manual ..................................................................................................................... 3 4.
.0 Specifications Model WACF-3037 COLD FRONT™ Stock number 28900 (UR,CSA), 0.5HP, single phase, 60Hz, 115VAC, 6.4A, 1100RPM, thermally protected (UR-c/us), 330W, 115VAC, 60Hz, 3A (VDE, ETL, CQC), 25W, 120VAC, 60Hz, .208mA, protected by water tank float switch 30 PSI (2 kg/cm2) 1200W, 120VAC, 60 Hz, 10A (UL) SJTW 3/C, 14AWG, 300V, 6’9” length, 120V plug installed 120V with GFCI, 5A max. output 1100 RPM 30 in. (76.2 cm) 20 mph (32 kph) 8462 CFM (14377 m3/hr) 19 gal. (71.9 L), 10 hrs.
Figure 5-1 Wilton WACF-3037 Cold Front 5
Read and understand the entire contents of this manual before attempting to operate the Cooling Fan. Failure to comply may cause serious injury. left on, the fan will start immediately once unit has cooled down sufficiently. A float switch in the tank will shut off the air compressor and water pump if water level falls below threshold. Fill tank to continue operating. 5.0 Setup and operation 5.4 GFCI test No assembly is required for the Cooling Fan. 1. Plug cord into power source.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal.
• If an individual nozzle is blocked, remove post (A, Figure 7-1), push blue rings (B) to pull out hoses, and remove entire nozzle unit (C). Soak nozzle unit in vinegar. Reinstall nozzle unit and test. 2. Loosen (do not remove) four hex cap screws (D, Figure 7-2). 3. Turn pan head screws (E) equally. 4. Retighten hex cap screws (D). Figure 7-2 7.5 Air pressure valve Figure 7-1 7.
8.0 Troubleshooting Wilton WACF-3037 COLD FRONT™ Problem Fan motor will not start. Possible cause No incoming current. Fan motor will not start: fuse blows or circuit breaker trips. Faulty start capacitor. Faulty motor. Too many machines on shared circuit. GFCI on machine has tripped. Short circuit in line cord or plug. Motor overheats. Thermal protector trips frequently. Loud noise or vibrations coming from machine. Not cooling, or unsatisfactory misting effect.
9.0 Replacement Parts for WACF-3037 COLD FRONT™ To order parts or reach the Wilton service department, call 1-800-274-6848 Monday through Friday, 8:00 a.m. to 5:00 p.m. CST. Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately. Non-proprietary parts, such as fasteners, can be found at local hardware stores or may be ordered from Wilton. Part No.
10.0 Warranty and service Wilton® warrants every product they sell against manufacturers’ defects. If one of our tools needs service or repair, please contact Technical Service by calling 1-800-274-6846, 8AM to 5PM CST, Monday through Friday. Warranty Period The general warranty lasts for the time period specified in the literature included with your product or on the official Wilton branded website. The WACF-3037 Wilton COLD FRONT Atomized Cooling Fan carries a ONE-YEAR warranty.
427 New Sanford Road LaVergne, Tennessee 37086 Phone: 800-274-6848 www.wiltontools.