E V I T A NT E INSTRUCTIONS TUSER THE CLEAR™440 SERIES C4-XP model In-the-ear
YOUR WIDEX CLEAR™440 HEARING AID (To be filled out by the hearing care professional) Date: _____________________________________ Battery size: _______________________________ Vent: Vent No vent 2
CONTENTS SYMBOLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 THE HEARING AID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Acoustic indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 The battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Inserting the battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Low battery indication . . . . . . . . . . . . . . . . . . . . . . . . .
SYMBOLS The following symbols will be used throughout the manual: WARNING Messages with this heading indicate serious adverse reactions, potential safety hazards and inadequate performance of device. CAUTION Messages with this heading indicate/include information regarding any special care to be exercised. Not for general waste.
THE HEARING AID 1. 2. 3. 4. 5. 6. Microphone openings On/off function Nail grip Sound outlet NanoCare wax guard Vent (Not in all models).
WARNING This booklet contains important information and instructions. Please read this booklet carefully before you start using the hearing aid. NOTE Your hearing aid and accessories may not look exactly as illustrated in this booklet. We also reserve the right to make any changes considered necessary.
Intended use The CLEAR hearing aids are intended as air conduction amplification devices to be used in everyday listening environments. The CLEAR hearing aids may be provided with the Zen program intended to provide a relaxing sound background (i.e. music/noise source) for adults who desire to listen to such a background in quiet.
Right/left identification A right-ear hearing aid has a red Widex logo, and a leftear hearing aid a blue logo. The arrow shows the position of the logo. Acoustic indicators The hearing aid may be set to produce a signal to indicate the use of certain functions. The signal may be a spoken message or tones adjusted by the hearing care professional in consultation with you. The signal can also be deactivated.
The battery We recommend zinc-air batteries. Use a size 312 battery for the hearing aid. To obtain replacement batteries, please consult your hearing care professional. It is important to take note of the expiry date and the recommendations regarding disposal of used batteries on the battery pack. Inserting the battery Before inserting a new battery into the hearing aid, remember to remove the adhesive tab. Once the tab has been removed, the battery will start functioning after a few seconds.
Use the nail grip to push the battery compartment cover downwards and open the cover. Do not press the battery compartment cover beyond the open position. Place the battery so that the plus (+) sign of the battery faces upwards. You can use the battery magnet provided to steer the battery into place. If the battery compartment cover does not close easily, the battery is incorrectly inserted. When changing battery, it is a good idea to hold the hearing aid over a table.
Low battery indication An acoustic indicator will sound when the battery is nearly exhausted, unless this function has been disabled (see page 8). We recommend that you always have a spare battery with you. WARNING Never leave an exhausted battery in the hearing aid. Exhausted batteries may leak, damaging the hearing aid. WARNING Your hearing aid may stop functioning, for instance if the battery is exhausted.
Turning the hearing aid on and off The battery compartment cover of your hearing aid also functions as the on/off switch. Close the battery compartment cover and push it upwards to turn the hearing aid on. An acoustic indicator will indicate that the hearing aid has been switched on unless this function has been disabled. Push the battery compartment cover downwards to turn the hearing aid off. Please remember to turn off the hearing aid when it is not in use.
Positioning the hearing aid Close the battery compartment cover completely. Hold your hearing aid with your thumb and forefinger. Slowly guide the hearing aid into your ear canal until you feel resistance. Let go of the hearing aid and use the tip of your forefinger to gently push it into your ear until it rests comfortably in your ear canal. To help position the hearing aid properly you could pull the outer ear backwards and upwards with the opposite hand.
Removing the hearing aid Hold the hearing aid with your thumb and forefinger and pull gently. If it is difficult, you can try to move the hearing aid carefully from side to side. It may also help to pull the outer ear backwards and upwards with the opposite hand.
Volume adjustment The hearing aid volume is adjusted automatically in accordance with your sound environment. If you have a remote control, you can also adjust the volume manually or mute your hearing aid. Any adjustment of the volume setting will be cancelled when your hearing aid is turned off, or when you change program. In the default setting, any volume adjustment via the remote control will affect both hearing aids.
Lost partner alarm (Note: Only applicable if this feature has been activated by your hearing care professional). If one of your hearing aids falls out of your ear, and/ or the battery is exhausted, a tone signal and a spoken message will sound two times in the other hearing aid. Listening programs By default, your hearing aid has one listening program. If you have a remote control, your hearing aid may be provided with five of the following programs, plus the special Zen program called Zen+.
Master Standard Music For listening to music TV For listening to the TV Comfort Attenuates background noise Reverse focus Focus on sounds from behind Audibility Extender Makes high-frequency sounds audible Phone For listening to the telephone Zen Generates different kinds of tones. Contains one style Compound programs The Master program in one ear and Zen, Audibility Extender, Reverse focus, or Phone in the other.
If your needs change over time, the combination of listening programs can be altered. The Zen program may be used with amplification so that both the surrounding sounds and the Zen tones are heard together. Or, it may be used alone (without amplification) in quiet when you are not required to hear surrounding sounds. The duration of the Zen play time can be set by your hearing care professional according to your needs.
Switching between the listening programs Each time you change program via a remote control, an acoustic indicator will sound unless this function has been disabled. Program 1: Program 2: Program 3: Program 4: Program 5: Zen+: Message or one short beep Message or two short beeps Message or three short beeps Message or one long and one short beep Message or one long and two short beeps Message or tone In the default setting, both your hearing aids will be affected when you change programs.
CLEANING The following cleaning accessories are available for the hearing aid. 1. Cloth 2. Brush 3. Wax removing tool 1. 2. 3. Contact your hearing care professional if you need additional supplies of cleaning accessories.
The hearing aid It is very important for the hearing aid’s performance that it is kept free from earwax and dirt. Clean your hearing aid daily with the soft cloth to keep it dry and clean of earwax or dirt. WARNING Never clean the hearing aid with water or cleaning solutions, as this may cause it to malfunction. When the hearing aid is not in use, the battery compartment cover should be left open to ventilate the hearing aid and allow it to dry.
We recommend that every time you take the hearing aid out of your ear, you inspect the sound outlet and the vent openings to ensure that no earwax or dirt has gathered there. Below is an example of how the sound outlet and vent openings may be positioned. The positions can be slightly different on your hearing aid. 1. Sound outlet 2.
The sound outlet It is important that the sound outlet is not blocked by earwax. If it is blocked, do as follows: Remove any visible earwax from around the sound outlet with the small brush or cloth. Do not attempt to clean the wax guard, If the sound outlet is still blocked, you should change the wax guard (see pages 24-27). WARNING If you cannot clean the sound outlet completely, you should contact your hearing care professional.
The vent If earwax has accumulated in and/or around the vent opening, do as follows: Clean any earwax from the vent by passing the wax removing tool all the way through the vent. WARNING It is important for the performance of the hearing aid that the vent is never blocked by earwax. Make it a habit to clean the vent every day! In rare cases so much earwax can accumulate in the vent that the hearing aid sound is affected. In that case you should see your hearing care professional.
NANOCARE WAX GUARD The NanoCare wax guard helps to protect the hearing aid against earwax. Always use NanoCare wax guards with your hearing aid. Otherwise the warranty for your hearing aid will be void. The NanoCare wax guard consists of the following parts: 1. Holder 2. Removal hook 3. Wax guard CAUTION The wax guard is disposable and for one-time use only. Do not attempt to clean or reuse a wax guard. This could damage your hearing aid and/or cause the wax guard to become dislodged in your ear.
Changing the Nanocare wax guard Insert the removal hook into the used wax guard placed in the sound outlet. Pull the wax guard straight out. 1. Vent opening 2. Sound outlet 3.
Turn the holder around so that the new wax guard is in position to be inserted. Insert the holder into the opening of the sound outlet and gently press the wax guard into the opening. Then pull the holder straight out. The new wax guard will automatically detach from the holder. Press the hearing aid gently against a flat surface to ensure that the wax guard remains in place.
Discard the holder with the used wax guard. The frequency with which the NanoCare wax guard should be changed varies from one individual to another. If you have any questions regarding your NanoCare wax guard, please contact your hearing care professional. WARNING If the wax guard fits loosely, discard it and insert another. If the wax guard becomes dislodged from the hearing aid while in the ear canal, please contact your physician. Do not try to remove the wax guard from your ear canal yourself.
ACCESSORIES A variety of assistive listening devices are available for your hearing aid. • RC-DEX • TV-DEX • M-DEX For help in determining whether you could benefit from a remote control or other accessories, please consult your hearing care professional.
IN CASE OF MALFUNCTION The following pages contain some quick advice on what to do if your hearing aid stops working or performs unsatisfactorily. If the problems persist, contact your hearing care professional for assistance.
Problem Possible cause The hearing aid volume is not powerful enough The battery is nearly Insert a new battery in exhausted the hearing aid The hearing aid whistles continuously Solution The sound outlet is blocked See page 23 Your ear is blocked by earwax Contact your ENT doctor/physician Your hearing may have changed Contact your hearing care professional Your ear is blocked by earwax Contact your ENT doctor/physician The hearing aid is not correctly placed in your ear canal Take the heari
Problem Possible cause Solution If the hearing aid is uncomfortable to wear The hearing aid is not correctly placed in your ear canal. Consult your hearing care professional on how to place the hearing aid correctly in your ear canal The hearing aid Contact your hearing does not fit your ear care professional properly Your outer ear or ear It is important that canal is sore first-time users only wear the hearing aid for short periods of time at the beginning.
Problem Possible cause The hearing a. The DEX is used aids do not beyond the transrespond with mission range a correspond- b. Strong electroing change magnetic interfein volume or rence in the program to vicinity the DEX c. The DEX and the CLEAR hearing aids are not matched The wearer hears “interrupted” speech (on and off) from the hearing aids or no speech (muted) from the transmitting ear. Solution a. Move the DEX closer to the CLEAR hearing aids b. Move away from known source of EM interference c.
CARING FOR YOUR HEARING AID The hearing aid is a valuable object and should be treated with care. Here are some things you can do to prolong the life of your hearing aid: CAUTION • Turn off your hearing aid when it is not in use. Remove the battery if the hearing aid will not be used for several days. • When the hearing aid is not in use, keep it in its case in a cool, dry location out of reach of children and pets. • Do not expose the hearing aid to extreme temperatures or high humidity.
WARNINGS WARNING Hearing aids and batteries can be dangerous if swallowed or used improperly. Swallowing or improper use can result in severe injury or even fatalities. In case of ingestion, contact a physician immediately. • Keep hearing aids and their parts, accessories and batteries out of reach of children and anyone else who might swallow such items or otherwise cause injury to themselves. Do not change batteries in front of them and do not let them see where you keep your battery supply.
WARNING • Risk of explosion if battery is replaced by an incorrect type or recharged. Dispose of used batteries according to the instructions. • Never allow others to wear your hearing aid, as this could cause permanent damage to their hearing. • When selecting a listening program, please remember that there are situations in which it is particularly important to be able to hear the surrounding sounds (e.g. traffic, warning signals). • The hearing aid is made of modern non-allergenic materials.
WARNING • Do not wear your hearing aid during radiation, X-rays, MRIs, CT or other medical treatments and scans. The emissions from these procedures as well as from other types of radiation, such as that in a microwave oven, can damage your hearing aid. Radiation from, for example, room surveillance equipment, burglar alarms and mobile phones is weaker and will not damage the hearing aid, but may create audible interference.
ADVICE NOTE • The hearing aid will not restore normal hearing and will not prevent or improve a hearing loss resulting from organic conditions. However, the hearing aid can help you to make the best possible use of your remaining hearing ability. You should also bear in mind that it can take time to get used to a new hearing aid and new sounds. • In most cases, using the hearing aid infrequently will not permit you to gain full benefit from it.
FCC ID: TTY-C4XP IC: 5676B-C4XP Federal Communications Commission Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
— Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help. NOTE: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Industry Canada licenceexempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada.
REGULATORY INFORMATION Hereby, Widex A/S declares that this C4-XP is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the Declaration of Conformity can be found at: http://www.widex.
Hearing aids, accessories and batteries should not be disposed of with normal household waste. Please consult your national Widex distributor for advice on how to dispose of these items.
Manufacturer ¡9 514 0132 001S¤ ¡#01v¤ Printed by HTO / 2011-04 9 514 0132 001 #01