A I R E N G I N E E R E D OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING ON BOARD FAN MOTOR UNITS
CONGRATULATIONS Congratulations and thank you for choosing a Whispair rangehood. To avoid the risks that are always present when you use an electrical appliance it is important that the rangehood is installed correctly and that you read the safety instructions carefully to avoid misuse and hazards. We recommend that you keep this instruction booklet for future reference and pass it on to any future owners.
PRODUCT DESCRIPTION & CARTON CONTENTS CARTON 1 - HOOD UNIT WITH INTEGRATED FAN MOTOR You will be supplied with one of the three hood unit options detailed below. OPTION 1 - INTEGRATED HOOD MODELS INCLUDED: X3M06S6.OU(T/B), X3M06S5.OP(T/B), X3UM06S5.OP(T/B), X3M09S6.OU(T/B), X3M09S5.OP(T/B), X3UM09S5.OP(T/B), X3M12S5.OP(T/B), X3M12S6.OU(T/B), X3MD09S6.OU(T/B), X3MD09S5.OP(T/B), X3UD09S5.OP(T/B), X3MD12S6.OU(T/B), X3MD12S5.OP(T/B) & X3UD12S5.OP(T/B) INCLUDED IN THE CARTON: 1.
CONDITIONS OF USE AND MAINTENANCE This rangehood is a domestic appliance which has been manufactured and tested to comply with Australian and New Zealand Standard AS/NZS 60335.2.31 and is designed to work under Australian and New Zealand conditions. The hoods are designed to remove bi-products of cooking – heat, steam, grease and odour. This appliance is intended for domestic application only. Any other usage is at the owner’s risk and could be dangerous.
DUCTING AND EXTRACTION LEVELS WHISPAIR onboard motor rangehoods must use at a minimum semi rigid ducting (not supplied) to ensure optimum performance for your rangehood. Please follow the installation instructions carefully. Every WHISPAIR rangehood must be ducted to the outside environment by the use of non-flammable ducting. The rangehood must not be ducted into a wall cavity or a ceiling space where a build-up of grease can occur and become a potential fire risk.
DUCTING OPTIONS WHISPAIR undermount or wall hung canopy hoods utilising on-board motor systems with rectangle duct can be top or rear ducted. Top Ducting: Top Ducted options come with a rectangular to circle transition piece which enables the semi rigid ducting to be connected. Transition Duct Top Outlet On-board Ultra with rectangle ducting, Top duct outlet Back Ducting: Back Ducted options come with a rectangular duct piece and a wall vent.
PART 1: HOOD INSTALLATION GUIDE Integrated Hood with Integrated Fan Motor Models included: X3M06S6.OU(T/B), X3M06S5.OP(T/B), X3UM06S5.OP(T/B), X3M09S6.OU(T/B), X3M09S5.OP(T/B), X3UM09S5.OP(T/B), X3M12S5.OP(T/B), X3M12S6.OU(T/B), X3MD09S6.OU(T/B), X3MD09S5.OP(T/B), X3UD09S5.OP(T/B), X3MD12S6.OU(T/B), X3MD12S5.OP(T/B) & X3UD12S5.OP(T/B) WARNING DIMENSIONS ARE ACCURATE AT THE TIME OF PRINTING, HAUS GROUP RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE.
PART 1: HOOD INSTALLATION GUIDE STEP 5: Using the ten (10) fixing holes, screw the Main Chassis into position. Top Ducted STEP 6: Once the Main Chassis is secured into the cabinetry, the Fascia can then be slid back inside the Main Chassis. Replace the screws (removed in Step 3) to fix the Fascia back into positon. STEP 7: Please note all Whispair rangehoods are required to be vented to the outside atmosphere. If this is not followed warranty may be void..
PART 1: HOOD INSTALLATION GUIDE Wall Hung Canopy Hood with Integrated Fan Motor Models included: X5L09S6.OU(T/B), X5L09S5.OP(T/B), X5S09S6.OU(T/B), X5S09S5.OP(T/B), X5V09S6.OU(T/B), X5V09S5.OP(T/B), X5R09S6.OU(T/B), X5R09S5.OP(T/B), X5R09W6.OU(T/B), X5R09W5.OP(T/B) & X5V12S6.OU(T/B) WARNING DIMENSIONS ARE ACCURATE AT THE TIME OF PRINTING, HAUS GROUP RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE.
PART 1: HOOD INSTALLATION GUIDE STEP 7: Secure the Chimney Bracket to the wall. Chimney Bracket Chimney Fixing Points STEP 8: Please note all Whispair rangehoods are required to be vented to the outside atmosphere. If this is not followed warranty may be void. Top Ducting - Place the supplied transition rectangle to 200mm round (HBX200TRANS) rectangle outlet Ultra 1680 motor only on the top of the outlet of the rangehood.
PART 1: HOOD INSTALLATION GUIDE Island Hung Canopy Hood with Integrated Fan Motor Models included: X7P04B6.OU/T, X7P04S6.OU/T, X7S09S6.OU/T, X7S09S5.OP/T, X7V09S6.OU/T, X7V09S5.OP/T, X7R09S6.OU/T, X7R09S5.OP/T, X7R09W6.OU/T and X7R09W5.OP/T WARNING DIMENSIONS ARE ACCURATE AT THE TIME OF PRINTING, HAUS GROUP RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. FOR BUILDING PURPOSES THE UNIT SHOULD BE PROVIDED TO THE CABINET MAKER / BUILDER / KITCHEN DESIGNER FOR EXACT MEASUREMENTS.
PART 1: HOOD INSTALLATION GUIDE STEP 6: Lift the stainless steel chimney into position and secure to the Ceiling Bracket with the four (4) screws supplied. If the chimney is required to be shortened, new holes may need to be drilled to secure the chimney cover. STEP 7: Please note all Whispair rangehoods are required to be vented to the outside atmosphere. If this is not followed warranty may be void.
OPERATION Operating your 4-button control panel Models included: Electronic Control or Touch Control TURNING THE EXTRACTION FUNCTION ON OR OFF: • In standby mode, press button 2 or 3 to change the speed. • The hood has three speed options and a 4th boost speed (4 speeds in total). • The LED indicators directly above the buttons indicates the speed setting selected. • To turn hood off, press button 2 repeatedly until hood returns to standby mode.
PRODUCT CARE It is recommended that your WHISPAIR rangehood and all of its items be cleaned regularly. Before any cleaning or maintenance work, disconnect the cooker hood from the mains power supply. CLEANING THE STAINLESS STEEL HOOD UNIT • It is expected that the stainless steel is cleaned with a quality non-abrasive stainless steel cleaner. • Use a soft cloth for application. • It is recommended that this is performed every 4 weeks.
WARRANTY Every retail WHISPAIR rangehood comes with a 5-Year parts and labour warranty. WHISPAIR Prague Commercial specific units comes with a 3-Year parts and labour warranty. This warranty is conditional upon the appliance being used only for personal, domestic and household purposes and installed and operated in accordance with WHISPAIR instructions. The consumer is responsible for any charges associated with removal of the faulty unit and installation of the new unit.