How to install, operate and maintain your Demand Controlled Water Softener Do not return water softener to store If you have any questions or concerns when installing, operating or maintaining your water softener, call our toll free number: 1-866-986-3223 Monday- Friday, 8 AM - 7 PM EST or visit www.whirlpoolwatersofteners.com When you call, please be prepared to provide the model and serial number of your product, found on the rating decal, typically located on the rim below the salt lid hinges.
TABLE OF CONTENTS Page Specifications & Performance Claims . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Water Softener Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Before You Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications & Performance Claims This model is efficiency rated. The efficiency rating is valid only at the minimum salt dose. The softener has a demand initiated regeneration (D.I.R.) feature that complies with specific performance specifications intended to minimize the amount of regenerant brine and water used in its operation.
Water Softener Safety Your safety and the safety of others are very important. We have provided many safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
Inspect Shipment The parts required to assemble and install the water softener are included with the unit. Thoroughly check the water softener for possible shipping damage and parts loss. Also inspect and note any damage to the shipping carton. Remove and discard (or recycle) all packing materials. To avoid loss of small parts, we suggest you keep the small parts in the parts bag until you are ready to use them.
Installation Requirements LOCATION REQUIREMENTS PLUMBING CODES Consider all of the following when selecting an installation location for the water softener. All plumbing must be completed in accordance with national, state and local plumbing codes. = Do not locate the water softener where freezing temperatures occur. Do not attempt to treat water over 120ºF. Freezing temperatures or hot water damage voids the warranty.
Installation Requirements VALVE DRAIN REQUIREMENTS 1/4” NPT Thread Barbs for 3/8” I.D. Tubing Using the flexible drain hose (included), measure and cut to the length needed. Flexible drain hose is not allowed in all localities (check your plumbing codes). If local codes do not allow use of a flexible drain hose, a rigid valve drain run must be used. Purchase a compression fitting (1/4 NPT x 1/2 in. minimum tube) and 1/2" tubing from your local hardware store. Plumb a rigid drain as needed (See Figure 5).
Dimensions 3-3/4” 19” IN 18” OUT IN – OUT 47-7/8” 41-1/2” 39-1/2” FIG.
Installation Instructions TURN OFF WATER SUPPLY Nozzle Venturi Assembly 1. Close the main water supply valve, located near the well pump or water meter. Top Cover Brine Tank Overflow Elbow Nut Ferrule 2. Open all faucets to drain all water from house pipes. NOTE: Be sure not to drain water from the water heater, as damage to the water heater elements could result.
Installation Instructions COMPLETE INLET AND OUTLET PLUMBING Measure, cut, and loosely assemble pipe and fittings from the main water pipe to the inlet and outlet ports of the water softener valve. Be sure to keep fittings fully together, and pipes squared and straight. Be sure hard water supply pipe goes to the water softener valve inlet side. Electrical Shock Hazard Prior to installation on metallic plumbing, securely install two grounding clamps and a #4 copper wire per installation instructions.
TEST FOR LEAKS Installation Instructions ADD WATER AND SALT TO THE SALT STORAGE TANK To prevent air pressure in the water softener and plumbing system, complete the following steps in order: 1. Fully open two or more softened cold water faucets close to the water softener, located downstream from the water softener. Excessive Weight Hazard Use two or more people to move and lift salt bags. Failure to do so can result in back or other injury. 2.
Programming the Water Softener SOFTENER status light SET SALT LEVEL button Display UP button PROGRAM button TANK LIGHT button DOWN button CONNECTION status light RECHARGE button FIG.
Programming the Water Softener PROGRAM THE SOFTENER SET RECHARGE (REGENERATION) TIME 1. Press the PROGRAM button once again to display a flashing “2:00AM” and the words “RECHARGE TIME”. This is a good time for the recharge to start in most households, because water is not in use. When the power supply is plugged into the electrical outlet, the model code (LLCS) and a test number (example: y10), are briefly shown in the display. Then the words “CURRENT TIME” appear and 12:00 PM begins to flash.
Programming the Water Softener continued from previous page 3. Be sure to set the correct salt type, depending on which type of salt is used (NaCl or KCl). Use the r UP or s DOWN buttons to toggle between NaCl and KCl, then press the PROGRAM button to enter the selection. 4. Press the PROGRAM button once again to return to normal operating display. Questions about installing or operating your water softener? Call Toll Free 1-866-986-3223 Monday- Friday, 8 AM - 7 PM EST or visit www.
Connecting to the Iris™ Cloud WI-FI CONNECTION PROCEDURE The Iris™ cloud is a home management system from Lowe’s. If you would like to connect to the Iris™ cloud, the water softener’s electronic controller must be in AP (Access Point) Mode: 1. Verify that the green connection status light on the control panel (see Fig. 15) is flashing twice, repeatedly. If it is not, follow the instructions under “Returning to AP Mode”on page 21. 2.
RECHARGE Customizing Features / Options SET SALT LEVEL The RECHARGE button is used to initiate an immediate recharge. The water softener has a salt monitor indicator light to remind you to add salt to the storage tank. 1. Press and hold the RECHARGE button until the words “RECHARGE", “SERVICE" and “FILL" flash in the display. RECHARGE initiated NOTE: You must set salt level each time salt is added to the water softener. To set this monitor system: 1.
Customizing Features / Options POWER OUTAGE MEMORY 2. Press the r UP or s DOWN buttons to set ON or OFF. When set to ON, the efficiency icon will be displayed in the lower left hand corner of the normal run display. If electrical power to the water softener is lost, “memory'' built into the timer circuitry will keep all settings for several hours. While the power is out, the display is blank and the water softener will not regenerate.
Customizing Features / Options CLEAN FEATURE MINUTES between recharges may be set from 1 to 15 days, as follows: NOTE: The softener will recharge on its own if needed, even if it is before the set number of days. 1. Press and hold the PROGRAM button until the screen in Figure 32 is displayed. Once in this display, press the PROGRAM button four times and the display in Figure 34 is shown. The Clean / Clear Water Iron Reduction feature (described above) may be adjusted, from 1 to 15 minutes in length.
ADDING SALT Routine Maintenance CLEANING THE NOZZLE & VENTURI Lift the salt lid and check the salt storage level frequently. If the water softener uses all the salt before you refill it, you will experience hard water. Until you have established a refilling routine, check the salt every two or three weeks. Always add if less than 1/4 full. Be sure the brinewell cover is on. NOTE: If using potassium chloride (KCl), do not fill above level 4 on the brinewell scale.
Troubleshooting AUTOMATIC ELECTRONIC DIAGNOSTICS This water softener has a self-diagnostic function for the electrical system (except input power and/or water meter). The water softener monitors electronic components and circuits for correct operation. If a malfunction occurs, an error code appears in the display. Switch is open (Cam not rotating) While an error code appears in the display, all buttons are inoperable except the PROGRAM button.
continued from previous page Troubleshooting RETURNING TO AP (Access Point) MODE If water does not enter the tank, look for an obstructed nozzle, venturi, fill flow plug, brine tubing, or brine valve riser pipe. Once a connection has been made to the Iris™ cloud, as described on page 15, the softener’s electronic controller will maintain it. If, for example, connection is temporarily lost due to an internet service interruption, the system will automatically reconnect when service is restored. 2.