YEid 4a 01 Installation lniiitionsand Use &Care Guide Air discharge Control panel Model and serial number plate (not shown) Control panel Model and serial number plate AIRCONDITIONERS Models ACS602XT ACS802XV ACSl02XT ACC602XT a-s3
Contents Page Electrical Requirements. .......... Receptacle wiring ................. Electrical requirements ............. Electrical connection .............. Installation Instructions ........... Installation instructions 1 ........... Installation instructions 2 ........... Operating Instructions ............ Starting your air conditioner ......... The exhaust control ............... Changing air direction .............. Cleaning and caring for your air conditioner ..................
ElectricalRequirements Electrical requirements are different for the two models pictured on the cover, depending on the ampere rating of your unit. The number of amperes is printed on the serial plate, which is attached to the front of the unit behind the front panel (see diagram on page 12). Observe all local governing codes and ordinances. Do not, under any circumstances, remove the power supply cord grounding prong. Receptacle wiring Receptacle wiring should be a minimum of 14 gauge.
Electrical Continued Requirements Electrically grounded metal cold water pipe Ground assembly (attach to grounded Grounded eyelet Grounding prong Temporary grounding method If changing and properly grounding the wall receptacle is impossible and where local codes permit (consult your electrical inspector), a temporary adapter may be plugged into the existing 2-prong wall receptacle to male with the 3-prong power supply cord. This, however, is not recommended.
1n back I’I _ 1. Unpack mounting parts before installing your air conditioner. Make sure you have all the necessary parts. A normal installation can be made with a screwdriver, saw, small level, pocket knife, tape measure, drill and W: 9/64” and %6” drill bits.
Installation Continued Instructions 4. Attach support bracket (Item 2) loosely to the underside of shelf with either short or long leg down and with end of bracket either toward or away from window, depending upon construction and depth of wall and window sill (see diagram). Attach sill bracket (Item 3). Each bracket is attached using one %6” bolt, nut and washers (Items 4,4A, 48 and 4C). Room side -16”- 5.
11. Peel backing from seal strip (Item 8) and press it onto side filler frame guides on each side of unit. Butt to bottom of flller frame. cut off axcess length unlt. below Seal strip 12. Place unit in wlndow by resting unit on shelf. Push unit toward window so side angles are sealing against the side jamb stop (see diagram). Slide the opened window sash firmly to make certain the frame and unit sealing strips are sealing. 13. Using Ye” drill, install locking screws (Item 7).
Installation Continued Instructions Add angle 16 or 19 gauge Shelf Add wood as shown Add angle to wood stop 16. For installation In windows having no slde flanges or with wood stops. The flanges (top and two sides) on the air conditioner must mate against companion flanges on the window, not more than 1/16” (.2 cm) in thickness. On the side with the opened sash, the leading edge of the sash becomes the flange. On the top and jamb side of most metal windows, the flange is there.
Installation Continued Instructions 5. Check the knurled knob screws to see that the top mounting brackets (Item 5) are retracted to the center of the unit. They must not interfere with the window frame when the unit is installed. 6. Lift the unit into the window opening and slide it back until the mounting frame comes into contact with the window frame. conditioner 7. Replace the bottom mounting brackets (Item 3) by hooking the bracket over the window frame.
Personal Injury Hazard Because this air conditioner weighs about 70 to 75 pounds, it is recommended that you have someone help you tnstall your new unit and that you both use proper lifting techniques. l This appliance must be installed according to all applicable codes and ordinances. l Handle the air conditioner with care. Watch out for the sharp metal fins on the front and rear coils. l Do not use the collected water for drinking purposes. It is not sanitary.
Operating Instructions Startingyourair conditioner L 1. Set exhaust control (if your unit is so equipped) to CLOSED for maximum cooling. 2. Choose either LO COOL or HI COOL fan speed setting. LO COOL ... . . . for sleeping comfort HI COOL . . . . . for maximum cooling FAN ONLY . . . . . . . . for circulating room air when no cooling is desired Models ACSSOZXT ACSSO2XV ACSlO2XT I If you turn your air conditioner off, wait at least two minutes before turning it back on or you may blow a fuse. I 3.
Operating Continued Instructions Cleaningandcaringfor your air conditioner Proper use and care of your air conditioner will help ensure longer life of the unit and lower operating costs. Follow these instructions carefully. Call your Whirlpool servicing dealer for an annual checkup. Cleaning of front panel Electrical Shock Hazard Disconnect from electrical supply before cleaning unit. Failure to do so could result in personal injury. 1. Remove the front panel from unit when cleaning.
Annual maintenance for your air conditioner Your air conditioner needs annual maintenance to help ensure steady, top performance throughout the year. Call the service company recommended by your dealer to: l Inspect and clean the coils and condensate water passages. l Check fan and oil the fan motor. l The compressor is sealed and needs no oiling. Expense of annual inspection is customer’s responsibility. -ORIf you are familiar with electrical appliances, you can do the cleaning and maintenance yourself.
Operating Continued Instructions Oiling the fan motor Electrical Shock Hazard Disconnect power cord from receptacle before oiling motor. Failure to do so could result in personal injury. 1. Oil the fan motor per instructions on the motor. To add oil, pull out the oil hole plug at each end of the motor (see diagram). An easy-to-use one-ounce capsule of especially recommended oil (Part No. 10943) can be ordered from your Whirlpool servicing dealer, or use SAE #20 non-detergent oil. 2.
If YouNeedServiceOrAssistance Wesuggestyoufollow thesefivesteps: satisfactory operation from your appliance or, if service is necessary, recommend a qualified service company in your area. 1. Before calling for assistance... Performance problems often result from little things you can find and fix yourself without tools of any kind. 3. If you need service’... Air conditioner won’t run: l Is unit plugged into a live circuit with proper voltage? l Is switch turned on? . Is thermostat set correctly? .
Whirlpool”RoomAir Conditioner Warranty AC00 LENGTH I OF WARRANTY 1 WHIRLPOOL WILL PAY FOR FULL ONE-YEAR WARRANTY From Date of Purchase FSP@ replacement parts and repair labor to correct defects in materials or workmanship. FULL FIVE-YEAR WARRANTY From Date of Purchase FSP replacement parts and repair labor to correct defects in materials or workmanship in the sealed refrigeration system. These parts are: 1. Compressor 4. Drier-Strainer 5. Connecting Tubing 2.