Instructions / Assembly
1
5. Unscrew the coinslide retaining bolt with
a 5/16” socket by turning counter clock
wise and remove the bolt.
6. Push the coinslide up, and then pull it
forward to remove from the metercase.
7. Set the coinslide and extension assembly
on a level surface and remove the return
spring(s) from the spring bracket.
8. Place coins in the coinslide of the proper
vend amount (factory preset on coin
equipped models is $1.00) and push the
slide all the way in until the coins drop
through the coinslide.
COINSLIDE PRICE VEND CHANGE INSTRUCTIONS
1. Unplug unit or disconnect power.
2. Unlock the metercase access panel or
collar control panel lock and remove the
control panel from the collar assembly.
3. On single washer and dryer models, lift
the metercase access panel up at the
back and remove.
4. On mechanical stack dryer models open
the console by lifting it up off the bottom
mounting flange. On electronic stack
dryers slide the control panel to the left,
then carefully open the control panel by
swinging the right side away from the
collar.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so can result in death or
electrical shock.
The following procedure will guide the user
through changing the coinslide vend amount
for a factory equipped or ESD vertical 8
coinslide. The procedure will be similar for
other coinslide manufacturers, consult the
manufacturers installation instructions. If the
coinslide(s) are installed, they must be
removed prior to changing the vend price. If
the coinslide(s) have not yet been installed,
skip to step 6.