Instruction for Use

AKT 424 PRODUCT DESCRIPTION SHEET
GB
5019 319 01499
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
PL
LIGHTING THE BURNERS
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting .
Press the knob against the control panel to ignite the burner.
After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids, etc.).
The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
- The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For better burner performance, please stick to the following
rules:
- Use pots and pans that fit the burners (see table on the
right).
- Only use flat-bottomed pots and pans.
- Use the correct amount of water for cooking foods and
keep the pot covered.
Important:
Improper use of the grids can result in damage to the hob:
do not position the grids upside down or slide them across
the hob.
Do not use:
- Cast iron griddles, ollar stones, terracotta pots and
pans.
- Heat diffusers such as metal mesh, or any other types.
- Two burners simultaneously for one receptacle (e.g. fish
kettle)
1. Removable panstand grids
2. Auxiliary burner
3. Semi-rapid burner
4. Semi-rapid burner
5. Ultra-rapid burner
6. Auxiliary burner control knob
7. Semi-rapid burner control knob
8. Semi-rapid burner control knob
9. Ultra-rapid burner control knob
SYMBOLS
Tap closed
Maximum flame
Minimum flame
Burner Pot Ø
ultra-rapid
from 24 to 26 cm
semi-rapid
from 16 to 22 cm
auxiliary
from 8 to 14 cm
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
NOTE: In case of installation of a hood above the cooktop, please refer to the hood instructions for the correct
distance.
INJECTOR TABLE CATEGORY II2ELwLs3B/P
ELECTRIC SUPPLY: 230 V ~ 50 Hz
Type of gas used Type of
burner
Injector
marking
Nominal
heating capacity
kW
Nominal
consumption
Reduced heat
capacity
kW
Gas pressure (mbar)
min. nom. max.
NATURAL GAS
(Methane) G23
ultra-rapid
semi-rapid
semi-rapid
auxiliary
136
104
95
78
3.50
1.90
1.65
1.00
333 l/h
181 l/h
157 l/h
95 l/h
0.60
0.35
0.35
0.30
16 20 25
NATURAL GAS
G2.350
ultra-rapid
semi-rapid
semi-rapid
auxiliary
188
140
129
104
3.50
1.90
1.65
1.00
463 l/h
251 l/h
218 l/h
132 l/h
0.60
0.35
0.35
0.30
10 13 16
NATURAL GAS
G27
ultra-rapid
semi-rapid
semi-rapid
auxiliary
152
115
106
84
3.50
1.90
1.65
1.00
402 l/h
221 l/h
189 l/h
115 l/h
0.60
0.35
0.35
0.30
16 20 23
LIQUID
PETROLEUM GAS
(Butane) G30
(Propane) G31
ultra-rapid
semi-rapid
semi-rapid
auxiliary
89
66
63
51
3.50
1.90
1.65
1.00
254 g/h
136 g/h
120 g/h
73 g/h
0.70
0.45
0.45
0.35
25 37 45
Type of gas used Configuration
model 4 burners
Nominal heating
capacity kW
Total nominal
consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20 20 mbar 4 burners 7.80 742 l/h 9.52
G2.350 13 mbar 4 burners 7.80 or 7.50 1031 l/h or 991 l/h 6.85
G27 20 mbar 4 burners 7.80 or 7.50 895 l/h or 860 l/h 7.90
G30/G31 37 mbar 4 burners 7.80 567 g/h 30.94