58Khz Floor Guard With Control Box Installation Manual Version: 2012 Manual Part Number: WG BTLFG IM (120203A) WG SECURITY PRODUCTS INC. 3031 Tisch Way, Suite 602, San Jose, CA 95128 (USA) http://www.wgspi.
WARRANTY DISCLAIMER WG Security Products Inc. makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, WG Security Products Inc. reserves the right to revise this publication and make changes from time to time in the content hereof without obligation of WG Security Products Inc. to notify any person of such revision or changes.
Technical Support Contact Information North America South America Tel: 949-545-6005 Toll Free: 888-633-5095 Fax: 949-545-6011 Email: service@wgspi.com Rest of World Tel: 4+49 8654 7715-21 Fax: 4+49 8654 7715-21 Email: support-ROW@wgspi.com CRITICAL NOTE As specified by FCC Regulations 15.21, any changes or modifications not expressly approved by the party responsible for compliance of this equipment, will void the user’s permission and authority to operate this equipment.
TABLE OF CONTENTS OVERVIEW ............................................................................................................................... 5 SYSTEM OVERVIEW ................................................................................................................. 5 SYSTEM CONFIGURATION......................................................................................................... 2 FLOOR GUARD FEATURES & BENEFITS ...............................................................
OVERVIEW System Overview Floor-Guard systems consist of one sealed floor antenna, a 58khz control unit and a smart power supply unit (WG SPS-24). The control unit provides all the control functions for the transceiver, including tag detection and alarm notification. The floor antenna is fully sealed and water-proof and can be buried in concrete or cement floor.
System Configuration The PLCU controls the transceiver through the TX control cable. All detection information is received through the RX cable. The Transformer power box powers the PLCU and transceiver through two separate cables. The following diagram illustrates the connections.
Specifications Electrical Primary Input (Stepdown Transformer) 230/115 ±10% @50/60Hz (Input) 26vac @ 4A (Output) Pedestal Input 26vac @50/60Hz Control Unit Input 26vac @50/60Hz Control Unit Rated Current 1.8A @ 26vac (The rated current data is given at driving 1500X400mm Floor Guard Antenna) Transmitter Output 1.6ms Burst Operating Frequency 58Khz Mechanical Floor Guard Antenna Length 1500mm (59”) Width 400mm (15.7”) Thickness 25mm (1.0”) Weight 15Kg (33.
PRE-INSTALLATION INFORMATION Floor Guard Control Unit Dimensions (All dimensions are in millimeters)
Floor Guard Antenna Dimensions (All dimensions are in millimeters)
INSTALLATION Parts List –Floor Guard Overall System Floor Antenna WG- 24vac Transformer WG SPS-24 Control Box WG Part Name Order Number 1. Floor Guard Antenna WG 2. Floor Guard Control Unit WG 3. 24vac Smart Power Supply WG SPS-24 4.
Quick Start for System Connections A Floor Guard system consists of a smart power supply (WG SPS-24), a Floor Guard Control Unit and a Floor Antenna. The smart power supply has a 6-pins 24vac outputs that can only power the Floor Guard Control Unit through 24vac and also communicate with the control unit for some tuning control and remote alarm display features. The PLCU is powered and controlled by the WG SPS-24 power supply unit.
Interior Cable and Connector Connections For interior Cable connection, user should open the control unit case, and take the two PC boards –socket connection board and the BTL AM board (ver4.1) out for access to the sockets for connection to FloorGuard antenna and the WG SPS-24 power supplies. Control Unit Aluminum Chassis Cable outlet for Floor antenna Cable outlet for WG SPS-24 Socket Connection Board BTL AM Board (ver4.
Power Cord Notices North American Power Supply Cords This equipment is supplied with an external power line at one end and a molded receptacle terminal block at the other end. Conductors are color coded white (neutral), black (line) and green or green/yellow (ground). Operation of this equipment at voltages exceeding 130vac will require power supply cords that comply with NEMA configurations.
Fuse Replacement Information The fuse holder is located on the control box inside Socket PC board. Fuse Replacement: Extended Fuse (Time-Delay Fuse) 5mm x 20mm 24vac @ T3.15A/250V 1. Equipment shall be electrically disconnected from the branchcircuit supply when replacing the fuse. 2. Remove the fuse holder with a screwdriver, rotating it in a counterclockwise direction. 3. Replace the fuse in accordance with the specification noted below.