Sentinel Installation Manual September 2010 Manual Part Number: WG-(TBD) (Ver.
WARRANTY DISCLAIMER WG Security Products Inc. makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, WG Security Products Inc. reserves the right to revise this publication and make changes from time to time in the content hereof without obligation of WG Security Products Inc. to notify any person of such revision or changes. WG SECURITY PRODUCTS INC.
TABLE OF CONTENTS OVERVIEW ................................................................................................................................................... 1 SENTINEL OVERVIEW ................................................................................................................................... 1 SPECIFICATIONS ........................................................................................................................................ 2 RAD & TAG DESCRIPTIONS .....
Sentinel Installation Manual OVERVIEW Sentinel Overview Sentinel represents the most advanced Asset Protection System on the market today. Sentinel is the perfect fit for applications requiring protection of critical assets, be they items for retail, research, or other property. Additional applications include protection of individuals in assisted living establishments, infants in hospitals, incarcerated people, etc.
Sentinel Installation Manual SPECIFICATIONS RAD Detection Performance (Field and EAS) Europe USA RAD Field Distance 20 m 65 ft RAD Cone Angle 120º 120º Electromechanical Specifications Europe USA Field/EAS RAD Dimensions 155x155x60mm 6”x6”2.4” POS RAD Dimensions 200x120x47mm 7.9”x4.7”x1.9” Field RAD Weights 0.343 Kg 0.76 lb EAS RAD Weight 0.388 Kg 0.86 lb POS RAD Weight 0.678 Kg 1.
Sentinel Installation Manual RAD & TAG DESCRIPTIONS Field RAD Field RADs are the readers installed in the room over the area to be protected. It radiates the area outward with a fixed 120º cone with strength adjustment range of up to 20 meters (65 feet). And it can be mounted on ceilings to cover an area below its conical beam or on walls to point to a direction and cover a conical space as well. Area Field is dependent on the height of the ceiling and signal strength.
Sentinel Installation Manual GENERAL RECOMMENDED RAD ARRANGEMENT Recognizing that each installation may easily differ in size and shape, RAD placement will vary to accommodate the differences. General Tips 1. Optimum RAD height mounting should be kept to 3-5 meters (10-16 feet). 2. In central ceiling of area, a field RAD should be installed in a central location. 3. Then some field RADs should be installed in corner or side-wall locations and tilted at 45º towards the center of the protected area. 4.
Sentinel Installation Manual 5
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.