CS17-145-410 Single Band Repeater LTE-700 Upper C
This page left intentionally blank.
Table of Contents Product Registration Information .................................................................................................... 4 Application .................................................................................................................................. 4 Radio and Television Interference ................................................................................................... 4 Important Safety Information.................................................
Product Registration Information The serial number may be found on the label on the bottom panel near the power connectors. Note this number below. Retain this manual, along with proof of purchase, to serve as a permanent record of your purchase. MODEL NUMBER SERIAL NUMBER PURCHASE DATE POINT OF SALE COMPANY DISCLAIMER: All information and statements contained herein are accurate to the best of the knowledge of Cellular Specialties, Inc.
Important Safety Information Antennas used for the purpose of radiating signals indoors are limited to a maximum gain of 3 dBi. The outdoor antenna used for the purpose of communicating to the wireless infrastructure is limited to 14dBi gain, or any combination of gain and loss that equates to 14dB at input. Each antenna must be positioned to observe minimum separation requirements from all users and bystanders. The following guidelines should be used when considering separation distances.
Feature Overview The CSI-repeater incorporates the following features for convenient operation, access, protection, and control. • Control using a Windows based Graphical User Interface and accessed by connecting a laptop or desktop computer the NMS 9 pin sub-D serial port.
Installation Tips Donor Antenna 1. 2. 3. 4. 5. Accurately determine the azimuth to the donor site . Obtain the donor site information and approval from the service provider/carrier. Ensure that the radiation path to the donor site is as unobstructed as possible. Mount the donor antenna at or toward the edge of the roof, in the direction of the donor site. Try to avoid having the RF signal from the donor pass above the location(s) of the service antennas.
Physical System Set-Up Verification All cables should be checked for shorts and opens. Also verify that there are no cables with loose or poor connections. RF leakage could cause oscillation to occur under some conditions. The rooftop antenna (Donor Antenna), if directional, should be checked for proper alignment along the calculated compass heading. Typically, the directional antenna would be aimed at the same site that your handset uses, but it may not always be so.
The following screen will be displayed showing the set up progress status. When the Install Shield Wizard has completed preparing setup, click next and you will be given the option to install to the default directory or choose another directory.
Directory Location Once the directory where the program is to be installed has been selected, click next to continue the installation. You will be given the option to review or change settings using the back button. If you’re satisfied with the settings click Install.
Installation Status During the install process the Setup Status screen is displayed, showing the progress of the software installation. When complete click finish to close the install wizard and begin using the software.
Starting the Program When the LTE700 software installation is complete the program may be launched by clicking start >CSI>LTE700.exe To configure the LTE700 software to communicate with the repeater, click the down arrow to the right of “COM port” selection box. A fly out menu will be displayed and allow the user to select the COM port configured for use on the controlling computer.
Status Mode The LTE700 repeater control software features three modes of operation, Status Mode, Control Mode and Management mode. Selecting the Status Mode by clicking the Status button allows the user to review the system settings for seven main categories. The SYSTEM box displays Manufacturer, Repeater Type, S/W Version and current Temperature. The ALARM section notifies the user if alarm conditions exist for PLL LD, Isolation, Shut Down (DL/UL), DC Fail and Relay Status.
Control Mode Selecting the Control Mode by clicking the Control button will display a similar user interface to the one used in the Status mode but allows the user to change the system settings described in the previous section. In this mode the user may make changes in the sections shown below. When the user has completed modifying all the fields he or she would like to change it is necessary to click the Control Send button to incorporate them into the repeater.
Specifications Section Repeater Photographs -15-
Outline Drawing -16-
System Block Diagram LTE - 700 Block Diagram Up Do n w Co n v er t o r ( UL ) Up Do n w Co n v er t o r ( UL ) HPA Dr i v e A MP( UL ) UP LINK UP LINK LNA ALC (0~25dB) RF SAW AGC (0~30dB) Gain ADJ 1st Mixer 2nd Mixer IF SAW Thermistor Thermistor Gain ADJ HPA Coupler Isolator DET PSU PL L CPU PLL Power Supply CPU (DC 6V, 24V) Isolation Check ATT Isolator Coupler IF SAW HPA ALC (0~25dB) RF SAW Thermistor LNA st 1 Mixer 2nd Mixer DET DOWN LINK DOWN LINK L NA / A L C( DL )
Power Specifications Parameter Specification Main Power Input Voltage AC110V @0.7A Remark Internal AC DC Power Supply Mechanical Specifications Parameter Specification Remark Size (Inch) 7.9” x 10.6” x 3.4” (L x H x D) Size (mm) 200 x 270 x 86.5 mm (L x H x D) Connectors Link/Service Antenna Ports AC Power In Frame Ground N – female AC cord 4.9 ft (1.
Alarm Interface POWER GREEN Off Repeater LED ISO Condition/Troubleshooting ALARM RED Off RED Off GREEN Blinking RED Blinking RED Blinking GREEN Solid RED Off RED Off GREEN Solid RED Solid RED Off GREEN Solid RED Off RED Solid GREEN Solid RED Off RED Blinking GREEN Blinking RED Off RED Off Power Supply has failed or unit is unplugged. Checking status. Normal condition at Power Up Insufficient isolation exists between the donor and DAS antennas. Turn off power.
One Year Limited Warranty Seller warrants that its products are transferred rightfully and with good title; that its products are free from any lawful security interest or other lien or encumbrance unknown to Buyer; and that for a period of one year from the date of installation or fifteen months from the date of original shipment, whichever period expires first, such products will be free from defects in material and workmanship which arise under proper and normal use and service.
Index A Alarm Configuration ............................................................................................................18 Alarm Interface ..................................................................................................................19 Alarm Relay .......................................................................................................................18 Application ..............................................................................................
Notes -22-
Notes -23-
960-1050-019 rev 004