Brochure/Catalogue

D
D.212729490000
Current measuring transducer
Measuring and monitoring of AC/DC current
Input/output electrically isolated
Input and output ranges are adjustable
Contact-free through-hole technology
Relay output for limit value alarm with switching
threshold, delay, hysteresis
Technical data
Input
Input measurement range
Input signal
Input frequency
Output (analogue)
Output voltage
Output current
Load resistance voltage
Load resistance current
Output (digital)
Type
Alarm function
Rated switching current
Max. switching voltage, AC
General data
Galvanic isolation
Accuracy
Configuration
Step response time
Temperature coefficient
Voltage supply
Insulation coordination
Rated voltage
Standards
Impulse withstand voltage
Test voltage
Pollution degree
Overvoltage category
Dimensions
Clamping range (nominal / min. / max.) mm²
Depth / Width / Height mm
Note
Ordering data
Connection type
Input measurement range 0...5/10 A Screw connection
Input measurement range 0...20/25/30 A Screw connection
Input measurement range 0...40/50/60 A Screw connection
Input measurement range: 0 to 40/50/60 A Screw connection
Input measurement range 0...5/10 A PUSH IN connection
Input measurement range 0...20/25/30 A PUSH IN connection
Input measurement range 0...40/50/60 A PUSH IN connection
Input measurement range: 0 to 40/50/60 A PUSH IN connection
Note
ACT20P-CMT
U/I
Ps
analog
output
configurable, 0…5/10 A AC (RMS) or DC
Current-carrying cable in feed-through hole, Diameter 10.5 mm
AC: 15…700 Hz (true root mean square), AC: 50 Hz (arithmetic
average)
Adjustable, 0...10 V, 2…10 V, 0...5 V, 1...5 V, -5…+5 V, -10...+10 V
Adjustable, 0...20 mA, 4...20 mA, -20…+20 mA
≥ 10 kΩ
≤ 600 Ω
Relay, 1 CO contact, normal / inverse adjustment
Surge current, Under-current, Alarm delay: 0…10 s, Hysteresis 5%
/ 10%
6 A
250 V
4-way isolator;, between input ⁄ output ⁄ supply ⁄ relay
< 0.75 % FSR
DIP switch and potentiometer
≤ 300 ms (RMS), ≤ 60 ms (AA)
≤ ±100 ppm⁄K @ -25…+55 °C, ≤ ±200 ppm/K @ +55…+70 °C
16,8 V…31,2 V
300 V AC
rms
IEC 61010-1:2010, 3rd Edition, IEC 61010-2-201:2013, 1st Edition,
EN 61326-1
6.4 kV (1.2/50 µs)
4 kV
2
III
Screw connection PUSH IN
1.5 / 0.5 / 2.5
113.6 / 22.5 / 119.2 114 / 22.8 / 127.1
Type Qty. Order No.
ACT20P-CMT-10-AO-RC-S 1 1510470000
ACT20P-CMT-30-AO-RC-S 1 1510540000
ACT20P-CMT-60-AO-RC-S 1 1510440000
ACT20P-CMT-60-RC-S 1 1510390000
ACT20P-CMT-10-AO-RC-P 1 1510330000
ACT20P-CMT-30-AO-RC-P 1 1510320000
ACT20P-CMT-60-AO-RC-P 1 1510290000
ACT20P-CMT-60-RC-P 1 1510280000
Output signals *
Power supplyOutput signal
Input signal
I for AC
44
43
42
41
54
53
52
51
24
23
22
21
GND
+16.8...31.2 V DC
Relay
Current
Current, voltage
*
-
+
V
-
+
CO
mA
Output
Output
Input
Supply
Output
Output
Input
Supply
I for DC
VLJQDO
7LPH
2XWSXW
W
DG
$ODUPGHOD\W
DG
$ODUPGHOD\
+\VWHUHVLV
+LJKDODUPVHWSRLQW
&XUUHQW
VLJQDO
/RZDODUP
7LPH
+\VWHUHVLV
/RZDODUPVHWSRLQW
t t
W!W
DG
WW
DG
W!W
DG
WW
DG
W
2XWSXW
W
DG
$ODUPGHOD\W
DG
$ODUPGHOD\
W
',3VZLWFK6
&XUUHQWLQSXWUDQJH 
$

$
$
$
$
$
$
$
0HDVXULQJPHWKRG 
7UXH506
$ULWKPHWLFDYHUDJH
$ODUPGHOD\WLPH 
V
V
V
V
██
0HDVXULQJUDQJH
PRQLWRULQJ

<HV
1R
2XWSXWHUURUDFWLRQ 
8SVFDOH
'RZQVFDOH
7UDQVIHUIXQFWLRQ 
1RUPDO
,QYHUVH
',3VZLWFK6
2XWSXWUDQJH 
9
9
9
9
██
9
9
██
P$
P$
██
P$
██
$ODUPUHOD\DFWLRQ 
(QHUJL]HG
'HHQHUJL]HG
$ODUPK\VWHUHVLV 


$ODUPW\SH 
+LJKDODUP
/RZDODUP
 21
 $&73&07$25&6
 $&73&07$25&6
 $&73&07$25&6$&73&075&6
Current measuring transducers
Signal converters and monitoring
components – ACT20P