Approval/Certificate/Document of Conformity

Page 10 of 23 Report No. 249955-TL6-1
IEC 61984
TRF No. IEC61984C
Testreport-249955-TL6-1.DOCX
VDE File No. 257500-1431-0044/249955
Dropping height .................................................. :
mm
VISUAL EXAMINATION: IEC 60512 Test 1a
6.18.1
No damage likely to impair safety
N/A
6.18.3
Internal insulations not damaged
N/A
Parts against electric shock not damaged
N/A
Clearances and creepage distances not reduced
N/A
SERVICE LIFE TEST GROUP B (TABLE 11)
B1
INITIAL MEASUREMENTS (CONTACT RESISTANCE): IEC 60512 Test 2b
Reference value for subsequent measurement:
See appended table B1
Test current ......................................................... :
1 A
B2
BREAKING CAPACITY (ONLY FOR CBCs)
7.3.5
Operating cycles ................................................ :
Speed of insertion/ withdrawal ........................... :
0,8 m/s
Test voltage ........................................................ :
V
Test current ........................................................ :
A
Power factor / cos() .......................................... :
0,9 0,05
Time constant
1 ms 15%
VISUAL EXAMINATION: IEC 60512 Test 1a
6.14.2
No damage occurred, which could impair normal
use
N/A
B3
MECHANICAL OPERATIONS: IEC 60512 Test 9a
7.3.9
Operating cycles ................................................ :
25
Insertion speed ................................................... :
0,01 m/s
Rest .................................................................... :
30 s
VISUAL EXAMINATION: IEC 60512 Test 1a
6.14.1
No damage occurred, which could impair normal
use
P
B4
FINAL MEASUREMENTS (CONTACT RESISTANCE): IEC 60512 Test 2b
Test current ........................................................ :
1 A