Approval/Certificate/Document of Conformity

Page 9 of 23 Report No. 249955-TL6-1
IEC 61984
TRF No. IEC61984C
Testreport-249955-TL6-1.DOCX
VDE File No. 257500-1431-0044/249955
Test acc. to: IEC 60068-2-20
Solder terminations
Male part
P
Other terminations, not mentioned above, acc. to
IEC standard ....................................................... :
N/A
A7
CONTACT RETENTION IN INSERT: IEC 60512 Test 15a
Test load shall be three times the specified
insertion force (mating) of one contact or the
specified insertion force of one contact plus 50 N,
whichever is less. Minimum test load 20 N.
insertion force of one contact:
3,4 N
Test load 20 N
VISUAL EXAMINATION: IEC 60512 Test 1a
6.18.2
Contacts safety retained
P
No axial displacement likely to impair normal
operation
P
A8
CABLE CLAMP: IEC 60512
6.17
The cable clamp is made of insulating material or
metal.
N/A
6.17
Metal cable clamps meet one of the following requirements:
a) Provided with a covering of insulating material to
prevent any accessible metal part becoming live in
case of a fault.
N/A
b) No contact possible with the IEC test finger
according to IEC 60529.
N/A
c) Be connected to protective earth.
N/A
Cable clamping range (6.17 Table 6 or
manufacturer’s specification) ............................. :
from: mm
to: mm
A8.1
CABLE CLAMP (PULL) IEC 60512 Test 17c
VISUAL EXAMINATION: IEC 60512 Test 1a
Covers mounted / contacts not connected
See appended table A8.1
N/A
A8.2
CABLE CLAMP (TORSION): IEC 60512 Test 17d
VISUAL EXAMINATION: IEC 60512 Test 1a
Covers mounted
See appended table A8.2
N/A
A9
MECHANICAL STRENGTH IMPACT (Only free Connectors and CBC): IEC 60512
Test 7b
Dropping cycles: 8 positions in 45° steps