Approval/Certificate/Document of Conformity

Page 10 of 28 Report No.: 2198607.50
IEC 61984
Clause Requirement + Test Result - Remark Verdict
Dropping height ................................................: 750 mm
VISUAL EXAMINATION: IEC 60512 Test 1a
6.18.1 No damage likely to impair safety P
6.18.3 Internal insulations not damaged P
Parts against electric shock not damaged P
Clearances and creepage distances not reduced P
SERVICE LIFE TEST GROUP B (TABLE 11)
P
B1 INITIAL MEASUREMENTS (CONTACT RESISTANCE): IEC 60512 Test 2b
Reference value for subsequent measurement: See appended table B1
Test current.......................................................: 1 A
B2 BREAKING CAPACITY (ONLY FOR CBCs) N/A
7.3.5 Operating cycles ..............................................:
Speed of insertion/ withdrawal ..........................: 0,8 m/s
Test voltage .....................................................: V
Test current ......................................................: A
Power factor / cos() ........................................: 0,9 0,05
Time constant
1 ms 15%
VISUAL EXAMINATION: IEC 60512 Test 1a
6.14.2 No damage occurred, which could impair normal use N/A
B3 MECHANICAL OPERATIONS: IEC 60512 Test 9a P
7.3.9 Operating cycles ..............................................: 25
Insertion speed .................................................: 0,01 m/s
Rest .................................................................: 30 s
VISUAL EXAMINATION: IEC 60512 Test 1a
6.14.1 No damage occurred, which could impair normal use P
B4 FINAL MEASUREMENTS (CONTACT RESISTANCE): IEC 60512 Test 2b P
Test current ......................................................: 1 A