Brochure/Catalogue

C
C.232729490000
Universal measurement and signal isolator-con-
verter
Output-loop powered
Universal isolator for intrinsically safe RTD signals,
thermal sensor signals, resistor signals, potentiometer
signals and DC signals (mA,V)
Supply via output loop
12.5 mm thin housing
PC configuration with FDT/DTM software, download at
www.weidmueller.com
Technical data
Input
Type
Temperature input range
Input current
Input voltage
Potentiometer
Input resistance, voltage/current
Output analogue
Output current
Load impedance current
Residual ripple (current loop)
Accuracy
Temperature coefficient
Step response time
Cut-off frequency (-3 dB)
General data
Voltage supply
Tightening torque, min. / Tightening torque, max.
Ambient temperature / Storage temperature
Approvals
Approvals
Insulation coordination
Insulation voltage / Rated voltage
Rated voltage
Standards
Impulse withstand voltage
Overvoltage category
Pollution degree
Dimensions
Clamping range (nominal / min. / max.) mm²
Depth / Width / Height
Note
Ordering data
1-channel version
Screw connection
PUSH IN connection
Note
ACT20X-HUI-SAO-LP-S
Ex Safe
OUTIN
I
U
R
J
I
to field to I/O (PLC)
intrinsically safe circuit
Adjustable from -200...+800°C
configurable, ± 25 mA, 0...20 mA, 4…20mA
configurable, ± 12 V DC (min. measurement range 1 V), ± 28 V DC
(min. measurement range 2 V), ± 600 mV DC (min. measurement
range 50 mV), ± 150 mV DC (min. measurement range 15 mV)
1.2…500 kΩ
> 10 MΩ @ 600 mV, 2 MΩ @ 28 V / 70 Ω
4…20 mA (max. 23 mA)
≤ 700 Ω
≤ 10 mV
ss
< 0.1 % of end value
< 0.02 °C of measuring range / °C
250 ms (10…90%)
100 Hz
via output current loop, 11…28 V DC (loop powered)
0.4 Nm / 0.6 Nm
0 °C...60 °C / -20 °C...70 °C
CE; EAC
3.51 kV between input and output / 300 V
eff
300 V
eff
DIN EN 61326-1, IEC 61010-1, IEC 61010-2-030, IEC 60079-0, IEC
60079-11, IEC 60079-15, IEC 60079-26
4 kV (1.2/50 µs)
III
2
Screw connection PUSH IN
2.5 / 0.25 / 2.5
113.6 / 12.5 / 117.2117.2 113.6 / 12.5 / 117.2117.2
Type Qty. Order No.
ACT20X-HUI-SAO-LP-S 1 1318220000
ACT20X-HUI-SAO-LP-P 1 2456210000
CBX200 USB configuration adapter - 8978580000
,QSXWV
7\SH 7KHUPRFRXSOHV7&57'P$
9ROWP9UHVLVWRUSRWHQWLRPHWHU
7\SH 6WDQGDUG /RZHU
OLPLW
8SSHU
OLPLW
0LQ
DUHD
%
,(&
& &&
( &&
&
- &&
. &&
/ ',1 &&
1
,(&
&&&
56 & &&
7 && &
8 ',1 && &
8VHUGHILQHG,QSXW
8SWRYDOXHV
(UURUGHWHFWLRQ 8SSHUHUURUVLJQDOOLQJYDOXH
P$
/RZHUHUURUVLJQDOOLQJYDOXH
P$
P$ P$#݁ P$
9ROW
9#0݁ 9
9#0݁ 9
P9
P9#!0݁ P9
P9#!0݁ P9
3W
3W
',1
& & &
3W
1L & 
&
&X & &&
8VHUGHILQHG,QSXW
8SWRYDOXHV
5HVLVWDQFH WRN
݁
WRN
݁
WR݁ ݁
3RWHQWLRPHWHU N݁WRN݁
7\SH 6WDQGDUG /RZHU
OLPLW
8SSHU
OLPLW
0LQ
DUHD
Intrinsically safe signal converters – ACT20X
Universal measurement transducers