Brochure/Catalogue

Selection guide
PLC Cables Interfaces
Input/Output cards Standard Direct inputs/outputs Insulated inputs Insulated outputs
- see page A.35 (H,R) or A.51 (A) -
- see page A.57 - - see page A.61 -
Manufacturer code Number/Type of channels Order No. Quantity Type Quantity Type Quantity Type Quantity
DI
1769-IA16 16 DI 7789025xxx 1 R2416 1
1769-IA8I 8 DI 7789016xxx 1 R2416 1
1769-IM12 12 DI 7789025xxx 1 R2416 1
1769-IQ16
16 DI, positive logic 7789770xxx 1 H2016 1 I2016 1
16 DI, negative logic
A)
7789831xxx 1 H2016 1
1769-IQ16F
16 DI, positive logic 7789770xxx 1 H2016 1 I2016 1
16 DI, negative logic
A)
7789831xxx 1 H2016 1
1769-IQ32 32 DI, positive logic
7789770xxx 1
H2016 2 I2016 2
7789695xxx 1
1769-IQ32
A)
32 DI, negative logic
7789831xxx 1
H2016 2
7789832xxx 1
1769-IQ32T
32 DI, positive logic 1489160xxx 1 H2016 2 I2016 2
32 DI, negative logic
A)
1489180xxx 1 H2016 2
DO
1769-OA16 16 DO 7789024xxx 1 R2416 1
1769-OA8 8 DO 7789017xxx 1 R1208 1
1769-OB16 16 DO 7789769xxx 1 H2016 1 O2016 1
1769-OB16P 16 DO 7789769xxx 1 H2016 1 O2016 1
1769-OB32 32 DO
7789769xxx 1
H2016 2 O2016 2
7789697xxx 1
1769-OB32T 32 DO 1489170xxx 1 H2016 2 O2016 2
1769-OB8 8 DO 7789015xxx 1 H2008 1 O2008 1
1769-OV16
A)
16 DO 7789769xxx 1 H2016 1
1769-OW16 16 DO 7789024xxx 1 R2416 1
1769-OW8 8 DO 7789017xxx 1 R1208 1
1769-OW8I 8 DO 7789016xxx 1 R2416 1
AI
1769-IF4 4 AI, current applications 7789026xxx 1 A1504 1
1769-IF4 4 AI, voltage applications 7789046xxx 1 A1504 1
1769-IF4I 4 AI, current applications 7789027xxx 1 A1504 1
1769-IF4I 4 AI, voltage applications 7789047xxx 1 A1504 1
1769-IF8 8 AI, current applications 7789028xxx 1 A2508 1
1769-IF8 8 AI, voltage applications 7789045xxx 1 A2508 1
AO
1769-OF2 2 AO 7789029xxx 1 A1504 1
1769-OF4CI 4 AO 7789043xxx 1 A1504 1
1769-OF8C 8 AO 7789044xxx 1 A2508 1
1769-OF8V 8 AO 7789044xxx 1 A2508 1
Note
A) Attention! Only use interfaces without LEDs
Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces.
In some cases, the card can work at higher voltages than those indicated in the interface.
The interfaces are intended to be used inside an IP20 enclosure at least.
The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
* In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at
www.weidmueller.com where you will always nd the most up-to-date information.
PLC ROCKWELL – COMPACT LOGIX
A
A.192690170000
Universal solutions for PLC input/
output cards