User Documentation
Communications
102 1435710000/01/05.13
Reset integral power
◊ This resets all integral power.
◊ To reset integral power, an operator's code should be defined, but this will not be stored and the code is
fixed to ‘0’. It is only available only by pressing the <MODE> key (programming key).
• Command from Master; control code 1AH
68H A0 A1 A2 A3 A4 A5 68H 1AH 08H
⇒
continue
Transmission address Control code
⇒
continue
PA P0 P1 P2
⇒
continue
Authorization
level (33H fix)
Password
(P2: 33H fix)
⇒
continue
C0 C1 C2 C3 CS 16H
Operator's code (33H fix)
• Response from Slave (normal)
68H A0 A1 A2 A3 A4 A5 68H 9AH 00H CS 16H
Abnormal command from Slave
Control code (C); C0H (Response from slave is abnormal.) + Control code when error occurs.
68H A0 A1 A2 A3 A4 A5 68H C 01H ERR 16H
Control code
Error code
(bit flag)
Contents of
error code
Bit flag Contents
Bit 7 Not support
Bit 6 Not support
Bit 5 Not support
Bit 4 Not support
Bit 3
Impossible to change
transmission speed
Bit 2 Password mistake
Bit 1 No request data
Bit 0 Other errors