Brochure/Catalogue

Threaddaten
Metric thread chart
Thread
Typ
Thread Size Outer Diameter Pitch Thread
Length
Min. Hexagon
Across Corner
ISO METRIC
(IEC 60423
1993)
M16 16 x 1.5 15.97 1.50 16.0 26.5
M20 20 x 1.5 19.97 1.50 16.0 33.0
M25 25 x 1.5 24.97 1.50 16.0 41.4
M32 32 x 1.5 31.97 1.50 16.0 50.6
M40 40 x 1.5 39.97 1.50 16.0 60.4
M50 50 x 1.5 49.97 1.50 16.0 71.5
M63 63 x 1.5 62.97 1.50 19.0 88.0
M75 75 x 1.5 74.97 1.50 19.0 99.0
M85 85 x 1.5 84.97 1.50 25.0 115.2
M90 90 x 1.5 89.97 1.50 25.0 125.7
Dimensions in mm
Ingress Protection
It is essential when selecting cable glands to ensure that the products will maintain the IP rating of the equipment and integrity of the installation.
IP Codes according to IEC Standard 529
Weidmüller cable glands are certied and designed for the following IP ratings:
IP66 Dust tight. No ingress of dust possible. Protected against heavy seas or powerful jets of water. Prevents ingress sufcient to cause harm.
IP67 Dust tight. No ingress of dust possible. Protected against harmful ingress of water when immersed between a depth of 150 mm to 1 m.
IP68 Dust tight. No ingress of dust possible. protected against submersion. Suitable for continious immersion in water at stated depth.
The minimum Ingress Protection requirement for hazardous area products are:
IP54 Dust protected. Prevents ingress of dust sufcient to cause harm. Protected from splashing water from any direction.
Gland weight data
Size Thread KDSU KDSW KDSX KUB KSG
G16 M16 164 144 144 165 84
G20S M20 160 130 130 165 90
G20 M20 250 186 186 240 94
G25 M25 400 262 262 400 152
G32 M32 750 420 420 725 176
G40 M40 1095 672 672 1060 332
G50S M50 1415 980 980 1435 570
G50 M50 1295 758 758 1340 458
G63S M63 2345 1410 1410 2100 850
G63 M63 2005 1140 1140 2025 684
G75S M75 1980 1745 1745 2330 954
G75 M75 2200 1375 1375 2240 764
G85 M85 3300 2655 2655 4065 1290
G90 M90 4314 3559 3559 5215 1510
Weights in grams
Klippon
®
Cable Glands
Threaddaten / Ingress Protection /
Gland weight data
351543550000