Approval/Certificate/Document of Conformity

SCHEDULE
EU-TYPE EXAMINATION CERTIFICATE Sira 05ATEX1286X
Issue 5
This certificate and its schedules may only be
reproduced in its entirety and without change
CSA Group Netherlands B.V.
Utrechseweg 310,
6812 AR, Arnhem Netherlands
DQD 544.09 Rev 2018-04-20 Page 5 of 5
-60C to +180C for the silicone seal variants
15.2 The KDSW and KDSX range of cable glands, when installed in accordance with the manufacturer’s
instructions and with an appropriate enclosure on which they are fixed, are capable of providing an
ingress protection of IP66 and IP68 (50 metres 7 days).
15.3 The KOSW and KOSX range of cable glands, when installed in accordance with the manufacturer’s
instructions and with an appropriate enclosure on which they are fixed, are capable of providing an
ingress protection of IP66.
15.4 If the KDSW, KDSX, KOSW and KOSX type cable glands only grip the cable sheath and do not clamp the
armour, or if they are used to terminate unarmoured, braided or screened cables, then they shall only
be used for fixed installations, hence the cables shall be effectively clamped to prevent pulling or twisting.
15.5 The threaded entry component threads without interface O-ring seals installed in an explosive dust
atmosphere, within threaded entries, shall only be fitted into enclosures that have either:
parallel entries that will ensure that a minimum of 5 full threads of contact will be maintained, this
is in accordance with clause 5.1.2 of EN 60079-31:2014,
tapered entries that will ensure that a minimum of 3 ½ full threads of contact will be maintained,
this is in accordance with clause 5.1.2 of EN 60079-31:2014
16 ESSENTIAL HEALTH AND SAFETY REQUIREMENTS OF ANNEX II (EHSRs)
The relevant EHSRs that are not addressed by the standards listed in this certificate have been identified
and individually assessed in the reports listed in Section 14.2.