Approval/Certificate/Document of Conformity

Annexe
to:
Applicant:
Apparatus:
srra
IECEx SIR
05.0067X
Issue 4
Weidmüller InteÉace
GmbH & Co. KG
Cable
Glands and Stopper Boxes
CSA
Group
CERTIFICATION
I
Specific
Conditions of Use
The KSG,
KSGDS and KCG Range
of Cable Glands
The KSG, KSGDS
and KCG Range of
Cable Glands shall
not
be used
in
enclosures where the temperature
at the
point
of entry/mounting exceeds
the
following.
-35oC
to
+90oC
for
the
Neoprene
seal variants
-60oC
to
+180oC
for the Silicone
seal
variants
The
cable entries are only suitable for fixed installations.
Cables
must
be effectively clamped to
prevent
pulling
or twisting.
The KSG, KSGDS
and KCG range
of cable
glands,
when
installed
in
accordance with the manufacturer's
instructions
and with an appropriate
enclosure on
which
they are fìxed, are capable of
providing
an
ingress
protection
of IP66 and IP68
(50
metres, 7
days).
The threaded
entry component threads without interface
O-ring seals
installed
in an explosive dust
atmosphere, within
threaded entries, shall only be fitted into
enclosures that
have
either:
r
parallel
entries that will
ensure that a
minimum
of 5
full
threads of contact will be maintained, this
is in
accordance with clause 5.1.2
of
EN
60079-31:2014,
.
tapered
entries that will ensure
that a
minimum
of 3
1/z
full threads of contact will be maintained,
this
is in
accordance with clause 5.1.2
of
EN
60079-31:2014
The KOSW/KOSX, KDSW/KDSX
and KISW/KISX ranges
The
KDSW, KDSX, KOSW
and
KOSX range
of cable
glands
shall not be used in enclosures where
the
temperature, at the
point
of contact exceeds the following temperatures:
-35"C
to
+90"C
for neoprene
seal
variants
-60'C
to
+180'C
for
the silicone sealvariants
il The
KDSW and KDSX range
of cable
glands,
when installed in accordance with
the
manufacturer's
instructions
and with
an appropriate enclosure on which they
are
fixed, are capable
of
providing
an
ingress
protection
of IP66 and IP68
(50
metres 7
days).
The KOSW
and KOSX range of
cable
glands,
when installed in
accordance with the manufacturer's
instructions
and
with
an appropriate enclosure
on
which
they are
fixed,
are capable of
providing
an
ingress
protection
of
IP66.
The threaded
entry component threads without interface
O-ring seals
installed
in an explosive dust
atmosphere, within threaded
entries, shall only be
fìtted
into enclosures that have either:
o
parallel
entries that will
ensure that a minimum of 5 full threads of contact will be maintained,
this
is in
accordance with clause
5.7.2 of
EN
60079-31:20t4,
.
tapered entries that will ensure
that a
minimum
of 3
1/z
full threads of contact will be maintained,
this is in accordance with
clause 5.L.2 of EN 60079-31:2014
If
the
KDSW,
KDSX,
KOSW
and KOSX type cable
glands
only
grip
the cable sheath and do not clamp the
armour, or
if
they are used to terminate
unarmoured,
braided
or screened cables, then they shall only
be used for fixed installations, hence
the cables shall be effectively clamped to
prevent pulling
or twisting.
ilt.
V
Date: O4June 2018
Sira Certification Service
Unit 6
Hawarden
lndustrial
Park,
Hawarden,
CHs
3US, United Kingdom
Tel:
+44
(O)
1244670900
Fax:
+44
(0)
1244681330
Email:
ukinfo(Ocsagroup.org
Web: wr¡uw.csagoupuk.org
Form 9530 Issue 1
PageT
of 9