User Documentation

- 13 -
Power
Input Voltage
12 to 48 VDC, redundant dual DC power inputs or 48
VDC Power-over-Ethernet (IEEE 802.3af)
Input Current
0.494A-0.121A (@ 12-48VDC)
0.3A @24 VDC
Reverse Polarity
Protection
Present
Mechanical
Casing
IP30 protection, aluminum case
Dimensions
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
Weight
850g
Installation
DIN-Rail, or wall mounting
Environmental
Operating Temperature
Standard models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature
-40 to 85ºC (-40 to 185ºF)
Ambient Relative Humidity
5 to 95% (non-condensing)
Standards and Certifications
Safety
UL 60950-1, EN 60950-1
Hazardous Location
UL/cUL Class I, Division 2, Groups A, B, C, and D;
ATEX Zone 2: Ex nA IIC T4 Gc
EMC
EN 301 489-1/-17; FCC Part 15, Subpart B; EN
55022/55024
Radio
EN300 328, EN 801 893, TELEC, FCC ID
SLE-WAPA003
WARRANTY
5 years
Weidmüller gives a 5 year warranty on this product in accordance with
the warranty terms as described in the general conditions of sale of the
Weidmüller company which has sold the products to you. Weidmüller
warrants to you that such products the defects of which have already
existed at the time when the risk passed will be repaired by Weidmüller
free of charge or that Weidmüller will provide a new, functionally
equivalent product to replace the defective one. Safe where expressly
described otherwise in writing in this catalogue/product description,
Weidmüller gives no warranty or guarantee as to the interoperability in
specific systems or as to the fitness for any particular purpose. To the
extent permitted by law, any claims for damages and reimbursement of
expenses, based on whatever legal reason, including contract or tort,
shall be excluded. Where not expressly stated otherwise in this warranty,
the general conditions of purchase and the expressive liability
commitments therein of the respective Weidmüller company which has
sold the products to you shall be applicable.
ATTENTION
The IE-WL-AP-BR-CL-ABG is NOT a portable mobile device and should
be located at least 20 cm away from the human body.
The IE-WL-AP-BR-CL-ABG is NOT designed for the general public. To
deploy IE-WL-AP-BR-CL-ABG and establish a wireless network safely, a
well-trained technician is required for installation.