User Documentation

Firmware release notes Industrial Wireless devices
January 28, 2020
Copyright © 2020 Weidmüller Interface GmbH & Co. KG 1 / 1
All rights reserved. Reproduction without permission is prohibited.
Firmware release notes of Industrial Wireless devices
Affected models:
Device name Article No.
IE-WL-VL-AP-BR-CL-EU 2536680000
IE-WLT-VL-AP-BR-CL-EU 2536690000
IE-WL-VL-AP-BR-CL-US 2536700000
IE-WLT-VL-AP-BR-CL-US 2536710000
Version 1.11.10 Build 18122616 Released: January 2020
Bug Fixes:
Abnormal behaviour where DFS does not operate as expected
Abnormal roaming handoff time if MAC clone enabled
Device reboots if received abnormal beacon which format does not follow standard IEEE.
Error handler for abnormal Wi-Fi packets does not work
Static route of WLAN interface does not work if it applies DHCP client in Client-Router mode
Version 1.11.2 Build 18082313 Released: September 2018
Bug Fixes:
Site Survey crashes after changing Operation Mode from Access Point to Client
New Features:
Support for WDS-mode (Wireless Distribution System)
Note: Limitations when using WDS-mode:
- When selecting RF types G/N Mixed, B/G/N Mixed or A/N mixed mode, only N-mode can be
effective.
- WDS only supports security mode “open” or WEP, but N-mode doesn’t support WEP.
- When “N mode” is configured as RF-type, then the security mode, using WDS, would be set to
“Open”.
- When WDS with “WEP” shall be used, RF-type must be set to B,G, B/G Mixed or A.
Version 1.9.2 Build 18030716 Released: April 2018
First release