Approval/Certificate/Document of Conformity

Page 12 of 28 Report No.: 2198607.50
IEC 61984
Clause Requirement + Test Result - Remark Verdict
THERMAL TEST GROUP C (TABLE 12)
P
C1 TEMPERATURE RISE TEST: IEC 60512 Test 5A
Test conductor length according Table 7 ...........: 500 mm
Test conductor cross-section.............................: 2,5 mm²
7.3.7 Mated specimen ...............................................: mated
Test current ......................................................: 17,5 A and 24 A
Ambient temperature components .................: 22,7 °C
Upper limit temperature components .............: 100 °C
6.16
The upper limiting temperature specified for the
specimen is not exceeded
See appended table C1 P
CLIMATIC TEST GROUP D (TABLE 13)
P
D1 INITIAL MEASUREMENTS (CONTACT RESISTANCE): IEC 60512 Test 2b
Reference value for subsequent measurement..: See appended table D1
Test current ......................................................: 1 A
D2 COLD: IEC 60512 Test 11j P
Mated specimen ...............................................: mated
Test duration ....................................................: 2 h
Lower temperature limit ....................................: -55 °C
VISUAL EXAMINATION: IEC 60512 Test 1a
6.6.3 Sufficient contact pressure through insulation P
6.8 / 6.15
No visual damage, no cracks on insulations parts
likely to impair safety
P
6.18.3
Internal insulation shows no damage likely to impair
safety
P
No damage occurred, which could impair normal use P