Page 13 of 28 Report No.: 2198607.50
IEC 61984
Clause Requirement + Test Result - Remark Verdict
D3 DRY HEAT: IEC 60512 Test 11i P
Mated specimen................................................: mated
Test duration ....................................................: 7 days
Upper temperature limit ....................................: 100 °C
VISUAL EXAMINATION: IEC 60512 Test 1a
6.6.3 Sufficient contact pressure through insulation P
6.8 / 6.15
No visual damage, no cracks on insulations parts
likely to impair safety
P
6.18.3
Internal insulation shows no damage likely to impair
safety
P
No damage occurred, which could impair normal use P
D4 PROTECTION AGAINST CORROSION: IEC 60512 Test 11g P
7.3.14
Test 1
Flowing mixed gas corrosion according to IEC
60512-11-7, test 11g Method 1 or alternatively
Method 4 (Table 1 of IEC 60512-11-7)). Test
duration is 4 days.
N/A
7.3.14
Test 2
alternative
Sulfur dioxide test with general condensation of
moisture according to ISO 6988.
Test duration is 24h (1 test cycle)
P
VISUAL EXAMINATION: IEC 60512 Test 1a
6.21 Function guaranteed P
No damage occurred, which could impair normal use P
D5 FINAL MEASUREMENT (CONTACT RESISTANCE): IEC 60512 Test 2b P
Test current ......................................................: 1 A
R2 1,5 R1 or R2 5 m + R1 ..................:
See appended table D5 P
D6 DIELECTRIC STRENGTH: IEC 60512 Test 4a P
Mated specimen ...............................................: mated
Impulse withstand voltage ................................: 4,8 kV
r.m.s. withstand voltage ....................................: 2,21 kV
6.13 No breakdown or flashover occurred See appended table D6 P