Approval/Certificate/Document of Conformity

Page 6 of 28 Report No.: 2198607.50
IEC 61984
Clause Requirement + Test Result - Remark Verdict
MECHANICAL TEST GROUP A (TABLE 10)
P
A1 VISUAL EXAMINATION: IEC 60512 Test 1a
6.2.2 Marking indelible and easily legible P
Minimum marking on the connector a) trademark P
Markings a) trademark and b) type identification on
smallest unit of packaging
P
All other markings (c k) given in the technical
documentation or catalogue of the manufacturer
P
c) Rated current ...............................................:
12 A for BLZP 5.08HC series
16,5 A for SL 5.08HC series
P
c) Rated voltage ...............................................: 250 V, 320 V, 400 V P
e) Over voltage category ..................................:
II (400 V)
III (250 V, 320 V)
P
f) Pollution degree ............................................:
2 (320, 400 V)
3 (250 V)
P
g) Protection degree .........................................: IP20 P
h) Range of temperature ...................................: LLT-55°C ULT 100°C P
i) Type of terminals ...........................................: Screw-type P
j) Connectable conductors ................................: 0,2-4,0 mm² P
k) Reference to this standard or to the DS DS P
6.2.3
Position for the contacts and protective earthing
contacts clearly indicated.
Marking of protective earthing contacts applies
symbol or PE. This requirement is not
necessary for non rewirable connectors.
N/A
6.9.2 Fixing means not used to fix live parts. P
6.9.3 Termination without damage possible. P
6.10 CBC has adequate breaking capacity. N/A
6.11
Free connector: Wires protected against shear and
tensile stress at the termination and secured to
prevent twisting.
P
The above requirement does not apply to:
a) free connectors for termination to cables in fixed
mountings (plug connection in the sense of a
detachable connection)
N/A