TS200 We Heal Smart TENS & Body Analyzer Version: 2019_v1.0 We Heal Biotechnology Co.
Content Table of Contents 1.Product Specifications 1.1 Device information 1.2 Intended use 1.2.1 Transcutaneous nerve stimulation 1.2.2 Electrical muscle stimulation 1.2.3 Impedance plethysmograph 1.2.4 Galvanic skin response 1.3 Contraindications 1.4 Precautions 1.5 Device summary description 1.6 Signs and symbols 1.7 Replacement parts and accessories 1.7.1 Electrodes 1.7.2 Connection cable 1.7.3 Other accessories 1.8 Contact information 2.General instructions 2.1 Buttons 2.2 Display 2.
Content Table of Contents 3.2 TENS/EMS auto (programmed) mode 3.3 TENS/EMS manual mode 3.4 Body analyzer 3.5 Alarms and problem solutions 3.6.1 Blue light 3.6.2 Orange light 3.6.3 Green light 3.6.4 Reset the machine 4.Warranty and ser vice 5.Electromagnetic compatibility information 6.
cifications e p S t c u d o r P 1. 1.1 Devic e inform ation Trade name WeHeal smart transcutaneous electrical nerve stimulation & body analyzer. Model TS200 Output waveform Monophasic or biphasic rectangular pulse Pulse length/ frequency 40 – 800 μs / 1 – 200 Hz Output voltage/ current Max. 50 V / 90 mA (500 ohm) Power specification DC 5V Treatment time Adjustable from 1 to 60 minutes Intensity Adjustable from 1 to 50 Bluetooth BLE 4.
fications i c e p S t c u d o 1.Pr 1.2 Inten ded use TENS- transcutaneous nerve stimulation symptomatic relief of neuro-muscular pain, chronic intractable pain, and post traumatic and post-surgical pain. EMS- electrical muscle stimulation Improvement and facilitation of muscle performance, relaxation of muscle spasm, increasing local blood circulation, prevention or retardation of disuse atrophy, and maintaining or increase range of motion.
ifications c e p S t c u d o r 1.P 1.3 Cont raindica tions The device is not a substitute for medical consultation and treatment. Consult your doctor first if you are experiencing any pain or are suffering from a chronic illness such as cancer, diabetes, high blood pressure, and blood coagulation/thrombo-embolic diseases.
ifications c e p S t c u d o r 1.P 1.4 Prec autions Do not expose the device to direct sunlight or high temperatures. Keep the device away from sources of heat and do not use it close (approx. 1 m) to shortwave or mobile phones, as doing so can result in unpleasant current peaks. Ensure that no metallic objects or high-frequency surgical devices are in contact with the electrodes during stimulation, which could result in electrical burns.
cations i f i c e p S t c u d 1.Pro 1.6 Sign s and sy mbols Do not use this product if you have implanted pacemaker installed IP22 SN Protected against ingress of solid foreign objects greater than 12.5 mm in diameter.
cations i f i c e p S t c u d 1.Pro aceme 1.7 Repl n t pa r t s and acce ssories 1.7.1Electrodes: Adhesive electrodes (small) Ø35mm x 2sets (4pcs); adhesive electrodes (Big) 97x47mm x 1set (4pcs). At distances below 5 cm, the unit primarily stimulates surface structures intensively. Greater distances (>15 cm) between electrodes mean a larger tissue volume is stimulated, but less intensively. Consequently, you must increase the impulse intensity.
uctions r t s n i l a r e n e 2.G ns 2.1 Butto ON/OFF button:Press 1 sec to turn on and 3 secs to turn off ENTER button:START/PAUSE button BACK button Shift button : switch the display of treatment setting MODE Setting button :choose left or right, increasing or decreasing the frequency, impulse width, and working time 2.2 Disp lay 1 2 1. Electrode positioning indicator 2. Impulse waveform 3. Number display 3 4 5 6 4.
ctions u r t s n i l a r e n 2.Ge 2.3 Devic e appea rance warning light The socket for the connection cables. Dimensions: 121 x 60 x 28 mm Weight: 134.2g Color: Black or pink 2.4 Initia l n o te s o The socket for the USB charging cord. n use Connect the connection cables with the electrodes. Guide the connection cable plugs into the socket on the top of the device. Do not pull, twist or make sharp bends in the cables.
uctions r t s n i l a r e n e 2.G 2.5 Start Step 1 Step 2 ing appl ications Pressure the ON/OFF button to switch on the device. Use the >/< button to navigate through the / / modes and press the ENTER button to confirm your selection. aning 2.6 Cle , storag e and d isposal Cleaning the device Please turn off the device while cleaning the device. Clean the device after use with a soft, slightly damp cloth. If it is very dirty, you can also moisten the cloth with a mild soapy solution.
3.Functions S/EM 3.1 TEN t S curren pa r a m e te r Impulse shape lmpulse intensity monophasic pulse It distinguishes between monophasic and biphasic pulse currents. In monophasic pulse currents, the current flows in one direction and in biphasic pulse currents the electrical impulse alternates its direction. The device provides both monophasic and biphasic rectangular wave.
3.Functions 3.2 T r S auto (p ENS/EM ogramm ed) mod e Step 1 The digital EMS/TENS unit features a total of 15 programs. Use the >/< setting buttons to select the program number you want and press the ENTER button to confirm your selection. Step 2 You can set the impulse intensity of both channels in all programs. Program table: Area of application, indications No. Mode 1 TENS Pain relief in shoulder, back and ankle 2 EMS Strengthening abdomen and back muscles 3 MASSAGE No.
3.Functions 3.3 TEN S/EMS m anual m ode Step 1 Place the electrodes on the desired area for treatment. Choose the waveform. Step 2 Set the impulse frequency between 1 to 200 Hz. Step 3 Set the impulse width between 1%-20% (40-800 μs). Step 4 Set the timer. Adjust the impulse intensity. respo nic skin er (galva y analyz 3.4 Bod nse and Program No.
3.Functions 3.
3.Functions ditional n o ad r further l.com fo w.wehea struction. w w it is V in ion and informat 3.6 App instructi 3.6.1 Blue light It represents that this device is charging. 3.6.2 Orange light It represents that at least one of the electrodes are not adhered to the body. Please adhere the electrodes to the body. 3.6.3 Green light It represents the device is in connection with correspondent Apps. 3.6.
d service n a y t n a r r a 4.W In case of a claim under the warranty please contact your local dealer or the local representation. In case of returning the unit please add a copy of your receipt and a short report of the defect. The following warranty terms shall apply: The warranty period for this product is 3 years warranty period from date of purchase. In case of a warranty claim, the date of purchase has to be proven by means of the sales receipt or invoice.
ty information li i b ti a p m o c c ti e n 5.Electromag Table 1. Guidance and manufacturer’s declaration – electromagnetic emissions The TS200 is intended for use in the electromagnetic environment specified below. The customer or the user of the TS200 should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment – guidance RF emissions CISPR 11 Group 1 The TS200 uses RF energy only for its internal function.
rmation fo n i y t li i b ti a p m o c 5.Electromagnetic Table 2. Guidance and manufacturer’s declaration – electromagnetic immunity The TS200 is intended for use in the electromagnetic environment specified below. The customer or the user of the TS200 should assure that it is used in such an environment.
rmation fo n i y t li i b ti a p m o c 5.Electromagnetic Table 3. Guidance and manufacturer’s declaration – electromagnetic immunity The TS200 is intended for use in the electromagnetic environment specified below. The customer or the user of the TS200 should assure that it is used in such an environment.
ty information li i b ti a p m o c c ti e n 5.Electromag Table 4. Recommended separation distances between portable and mobile RF communications equipment and the TS200 The TS200 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
ty information li i b ti a p m o c c ti e n 5.Electromag Manufacturer’s declaration-electromagnetic immunity Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment The TS200 is intended for use in the electromagnetic environment (for home healthcare) specified below. The customer or the user of the TS200 should assure that it is used in such an environment.
Statement ) C C F ( n o i ss i m m o C cations 6.Federal Communi This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Manufacturer: We Heal Biotechnology Co. Address: 9F., No. 205, Minsheng 2nd Rd., Chyan Jin Dist., Kaohsiung City 801, Taiwan (R.O.C.) Phone: +88672216313 Website: www.weheal.com Email: service@weheal.com.