WebEye B101 Manual Ver 1.0 WebEye B101 User’s Guide * This manual is for WebEye B101 firmware version 1.2.0. If you have later version of firmware, please download the last updated user’s guide from WebGate’s homepage (www.webgateinc.
FCC Compliance Statement Caution : Any changes or modifications in construction of this device which are not expressly approved the party responsible for compliance could void the user's authority to operate the equipment. NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Important Notice 1. WebEye B101 is not weatherproof. Therefore you should be well aware of environmental specifications that are included in the manual. In case of outdoor use, where it needs additional weather criteria, you should equip weatherproof case to protect WebEye B101 from water, moisture, or temperature (higher or lower than specification). For WebEye cleaning, g ently wipe with clean dry cloth. 2. Be sure to use a 12V DC or 24V AC adaptor to supply power to WebEye B101.
CONTENTS I. Introduction ..................................................................................................................................................................... 6 II. Product Description ..................................................................................................................................................... 7 1. Contents ...................................................................................................................................
3) Pop-up Menu.................................................................................................................................................... 18 4) To Home ........................................................................................................................................................... 18 5) Capture..............................................................................................................................................................
I. Introduction • What is WebEye B101? The WebEye B101 is a network dome camera server solution with an integrated Internet server, image compression device, flash memory, and many other features. No other hardware is necessary for use. The WebEye relay video source from a dome camera to network and provides real time images over networks and the Internet. Simply provide power and connect LAN cable and video cable to the WebEye. WebEye utilizes Wavelet image compression and Linux operating system.
II. Product Description 1. Contents Unpack and check all the items as below.
2) Rear view and description Connector Name DIP switch Video Input Video Output RS-232 RS-232 RS-422 RS-485 Description To designate video signal termination of ‘Video Input’ BNC connector. (Only the left switch is used) To input video signal through a coaxial cable. To output video signal through a coaxial cable. (Roof-through from ‘Video Input’ BNC connector) To communicate between WebEye and external devices such a dome camera, WebEye A10 (An audio transmission kit), or an external modem.
Green LED : This LED indicates the status of networking. After power is supplied, it is on for the first 1 -2 seconds, and then it blinks once at every one second as long as the network is connected. 4) Descriptions on DIP Switches This is to designate video signal termination. If you want to monitor real time image through a CCTV monitor as well as WebEye, you may connect a dome camera to ‘Video Input’ connector and a CCTV monitor to ‘Video Output’ connector.
V. Assigning IP Address and Configuring Administrator’s Condition. 1. Connecting WebEye to a PC 1) Connecting WebEye on Internet or LAN. You may use direct cable (white colored one) to connect WebEye on Internet or LAN. Though you connect WebEye as follows, a remote user may not access WebEye before you configure its network setting properly. 2) Connecting WebEye to a PC. You may use crossover cable (red colored one) to directly connect WebEye to a PC. This connection is just to configure WebEye. 2.
2) Configuring Administrator’s Conditions To access the WebEye’s Administrator’s Page from the Setup Menu, enter the admin.’s password and click the “Start Configuration” button. To configure several WebEyes simultaneously , follow the Steps below. However, some information such as “Date and Time at System,” “Serial Number,” and “IP Configuration at Network,” will not change. “Date and Time at System” and “IP Configuration at Network” can be changed in the Setup program. The“Serial Number”never changes.
3) Verifying Installation After successfully completing the above proc edures, the following message (or similar) will appear on the screen : Request timed out : Request timed out Reply from 200.243.232.178: bytes=32 time=2ms TTL=255 Reply from 200.243.232.178: bytes=32 time=2ms TTL=255 Ping statistics for 200.243.232.
If you key in user’s ID and password, you may access to a viewer to monitor real-time images. With administrator’s ID and password, you may also access to a real-time image viewer with administrato r’s authority. The default value of both user’s ID and password are ‘guest’, and administrator may change it at Admin page. But, each ID and password must be composed within 9 bytes. (e.g. 9 English letters) 2) Behind Firewall If your PC is connected on a network where firewall is.
3. Real time monitoring through Default Viewer At default viewer, a user may configure image transmission method and control integrated PTZ mechanism of a dome camera. The PTZ control panel is activated in some seconds depending on network speed. On the left side panel, there are menus for changing real time image viewer, accessing administration page, downloading Plug -in program and viewing information on version and Q&A.
an image is reproduced from vague to clear for user to see what is happening and later one may detect exact things. This function is useful when you use a low speed network, because it reduces waiting time. (3) Single Shot Mode When this button is clicked, one frame of image is reproduced. Therefore, it is stopped transmitting further image. To resume transmitting real-time i mages, click the button again. (4) Resolution You may select a level of resolution among 3 levels (360x243, 180x121, 90x60).
(1) Image Info You may decide the color (black or white) of the information that is shown on the left top of the image. And you may leave out the information. A user who has ‘Video control’ right may utilize this menu. (2) Quality Box This is to set a certain area clear and remained area dull. You can overcome insufficient network bandwidth with this function , because the file size is reduced with unfocused area. Quality Box is to be set like under written description. • • • Choose ‘New QBOX’ button.
4. Real time monitoring through Server Push Viewer If WebEye is installed on a network where firewall is, you may access WebEye through server-push viewer to monitor real-time images. 1) Image Control ‘Progressive Mode ’ image transmission menu is not supported. (1) Resolution You may select a resolution level among five. (90x60, 180x121, 360x243, 720x243, 720x486) (2) Frame Rate You may choose image transmission speed.
(4) Acceleration Rate You may choose moving speed of Pan/Tilt/Zoom mechanismamong three steps of fast, normal and slow. 3) Pop-up Menu ‘Image Quality’ control, ‘Quality Box’ creation, and ‘Focus Sensitivity’ control are not supported. (1) Image Info You may decide the color (black or white) of the information that is shown on the left top of the image. And you may leave out the information. A user who has ‘Video control’ right may utilize this menu.
2) Accessing through Web browser On Web browser, a user may access WebEye login page with its IP address. In the login page, a user may key in administrator’s ID and password or a normal user’s ID and password . With any of ID and password, the user may access real time image viewer page. 2. Configuring Administrator’s Condition at Homepage 1) System Configuration This page is to set name, date & time, location, and description of one’s WebEye.
There are one administrator’s account and 5 users ’ accounts. Account name can be changed. (2) Password If you want to open your WebEye to everyone, you may not change default user’s ID and password. However you should change administrator’s ID and password with unique ones of yours. (3) Access Rights Administrator may give or forfeit users’ right of PTZ control and video control. With default setting, administrator has both right of PTZ control and video control and normal user doesn’t have any right.
4) Dynamic IP registration service for ISDN and xDSL users This page is to register WebEye on dynamic IP registration server. If WebEye is installed on a network of dynamic IP address (floating IP address), administrator should register the WebEye to ‘dynamic IP registration server’ to give simple connectivity to common users. To solve the problem WebGate run a server making a list of WebEyes that have dynamic IP addresses.
5) How to find registered WebEye in WebEye Internet homepage On WebEye Internet homepage (www.webeye.to), there are menus to find WebEye that is registered on WRS (WebEye Registration Server). (1) Sign up membership To search your WebEye out of a public list or a private list, you have to sign up membership first. You may sign up on the server through ‘Membership ’ menu.
7) Video Configuration This page is to configure every channel with various conditions. (1) Video Channel State Control Administrator decides whether to utilize video signal from selected channel in WebEy e or not. If user disables a channel with an external camera connecting to WebEye, WebEye does not show any image from the channel. (2) Camera Color Type It is to define every camera whether it is color or B/W camera.
menu, Administrator may set quality level of unfocused area in the image (out of the focused range). • Image Quality Level: Administrator chooses image quality level from 0 to 9. If level 9 is chosen, WebEye sends the finest image. However, transmission speed will be reduced because of larger sized data. The image level inside the ‘QBOX ’ is the same level as is selected in this menu. 8) Application Configuration This page is to configure e -mail and file sending function.
Administrator assigns FTP server address, FTP user account, FTP user password, and FTP user path to receive files when events occur. (6) FTP event configuration Administrator may set sending conditions, image resolution, and filename. Image resolution, filename, and sending conditions setting methods for FTP are same as that of e-mail. 9) Pan/Tilt/Zoom Configuration This page is to select which serial port to use and to configure PTZ functions such as ‘Mode ’, ‘Preset’, etc.
you listed in a group, a dome camera travels. • • Click ‘Add/Change ’ button In ‘Current Group Member’ panel, all registered preset points appear. At the bottom of this window, you may check if the selected number is occupied or not. Mode There are three modes like ‘Normal Mode’, ‘Swing Mode’, and ‘Group Mode ’. • • • Under normal mode, user may control PTZ mechanism of a dome camera with corresponding buttons in control panel.
device to input port, you should select ‘NO (Normal Open)’. With normal close type device, you should select ‘NC (Normal Close)’. (2) Current State for Input Ports WebEye shows current states of the 4 digital devices connected to 4 input ports. In the status panel, active state or de-active state message shows. ‘De -Active State’ means that connected device didn’t detect any event when ‘Apply button ’ is clicked.
(3) Select Main Page Administrator assigns a viewer as a main page that appears when users access WebEye. Administrator can select between ‘Default Viewer’ and ‘720x486 Viewer’. ‘Default Viewer’ is to show images with maximum resolution of 360 by 243 and ‘720x486 Viewer’ shows images with maximum resolution of 720 by 486 (4) Default Viewer Editing ‘Default Viewer’ is designed for users to edit easily. Editable parts are as bellows .
(Appendix 1) Detailed Specifications of WebEye B101 1. General Hardware CPU 32bit RISC Embedded processor Flash memory 8Mbyte RAM 16Mbyte OS Embedded Linux Video Channel NTSC or PAL video format are supported 1Ch. Video Input 1Ch.
3. Mechanical Dimension Weight H x W x L = 35mm x 120mm x 120mm 350g 4. Environmental (*) This data is a target specification. Temperature * Operating Non-Operating -5° C ~ +50° C, Gradient 15°C/Hr max -20°C ~ +60°C, Gradient 15°C /Hr max Humidity * Operating Non-Operating 8% ~ 90% R.H. No condensation 8% ~ 90% R.H. No condensation Vibration * Acceleration Frequency Sweep Time Shock * 1.2G 10Hz ~ 60Hz 1 OCT/Min 10 G (10msec half sine wave Repeated twice maximum/sec) 5.