Product Manual

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
Please read and save these instructions. Read carefully before
attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in
personal injury and/or property damage! Retain instructions for
future reference.
Description
A sewage pump is intended for use in
domestic sewage lift stations. It is suitable
for pumping sewage, effluent, wastewater,
groundwater, and other nonexplosive,
noncorrosive liquids with up to 2 inch solids.
An acceptable
motor control
device must be provided at time of
installation.
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged during
shipment. If the pump or components are
damaged, return the unit to the place of
purchase for replacement. Failure to do so
could result in serious injury or death.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY and
to PREVENT EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
an imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially
hazardous situation which, if not avoided,
could result in death or serious injury.
!
WARNING
!
DANGER
NOTICE
Operating Instructions and Parts Manual Models DSP60 and DSP75
330600-001 6/03
Caution indicates a
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
General Safety Information
1. Know the pump application, limitations,
and potential hazards.
Do not use to pump
flammable or explosive
fluids such as gasoline, fuel
oil, kerosene, etc. Do not
use in flammable and/or explosive
atmospheres. Use pump only with
liquids compatible with pump
component materials. Failure to follow
this warning can result in personal
injury and/or property damage.
2. Make certain that the power source
(electric motor) conforms to the
requirements of the equipment.
Disconnect power before
servicing. If the power dis-
connect is out of sight, lock
in the open position and
tag it to prevent unexpected
!
DANGER
!
WARNING
NOTICE
!
CAUTION
application of power. Failure to do so
could result in fatal electrical shock!
3. Release all pressure within the system
before servicing any component.
4. Drain all liquids from the system before
servicing.
5. Secure the discharge line before starting
the pump. An unsecured discharge line
will whip, possibly causing personal
injury and/or property damage.
6. Check hoses for weak and worn
condition before each use, making
certain that all connections are secure.
7. Periodically inspect the pump and
system components. Perform routine
maintenance as required (See
Maintenance Section).
8. Provide a means of pressure relief for
pumps whose discharge line can be shut-
off or obstructed.
9. Personal Safety:
a. Wear safety glasses at all times when
working with pumps.
b. Keep work area clean, uncluttered
and properly lighted; replace all
unused tools and equipment.
c. Keep visitors a safe distance from the
work area. Make workshop child-
proof with padlocks, master switches,
and by removing starter keys.
10. When wiring an electrically driven pump
such as this, follow all electrical and safety
codes, as well as the most recent National
Electrical Code (NEC) and the Occupation-
al Safety and Health Act (OSHA).
© 2003 Wayne Water Systems
Specifications
Power supply requirements.............120V, 60 hz
Circuit requirements ........................15 amps (min)
Motor duty .......................................Intermittent
Motor ................................................120V, 1 Phase
Horsepower .....................................6/10 (DSP60), 3/4 (DSP75)
Motor full load.................................11.3A (DSP60), 11.8A (DSP75)
Liquid temperature range...............40°F to 120°F
Max. operating position..................45
o
from vertical
Dimensions .......................................14” x 12”
Intake ................................................2”
Discharge ..........................................2” NPT female
Power cord........................................16 gauge 3 conductor w/plug
Construction
Motor body material .......................Cold rolled steel
Motor housing .................................Cast iron
Volute ...............................................Cast iron
Impeller.............................................Cast iron
Seal plate ..........................................Cast iron
Shaft seal ..........................................Mechanical
GALLONS PER HOUR AT TOTAL HEAD IN FEET
Model 0’ 5’ 10’ 15’ 20’ 25’
DSP60 8200 7500 6000 4000 2000
DSP75 8800 8160 7080 4920 2880 700
Performance
Sewage Pump
For parts, product & service information
visit www.waynepumps.com
Para ordenar repuestos comuníquese con el
distribuidor de Wayne más cercano a su domicilio
Sírvase suministrarnos la siguiente
información:
- Número del modelo
- Número de Serie (de haberlo)
- Descripción y número del repuesto
según la lista de repuestos
Puede escribirnos a:
Wayne Water Systems
100 Production Drive
Harrison, OH 45030 U.S.A.
1 Tapón NPT de 6,4mm (1/4") 16356-004 1
2 Cordón de aliment., 3m (10 pies) 31035-001 1
3 Mango 23124 1
4 Caja del motor 41026-001 1
5 Anillo en O 19040-001 1
6 Ensamblaje del motor* 63004-001 1
7 Impulsor 41032-001 1
8 Voluta 41028-001 1
9 Tornillo de cabeza hex.
11,1mm (7/16")-14 x 3,2cm (1-1/4") ** 3
10 Tornillo de cabeza hex.
7,9mm (5/16")-18 x 8,3cm (1/4") ** 3
11 Tornillo de máquina de cabeza
redonda 10-24 x 12,7mm (1/2”) ** 2
*
Incluye motor, placa de sellado, sello del eje y anillo en O
**
Artículo de ferretería estándar
No. de No. del
Ref. Descripción Repuesto Ctd.
1
2
3
4
5
6
7
8
Diagnóstico de Averías
Problema Posible(s) Causa(s) Acción a Tomar
La bomba no se
enciende o funciona
La bomba se enciende y
se apaga
constantemente
La bomba se apaga y se
enciende
independientemente del
interruptor (el sistema de
protección térmica se
activa)
La bomba hace mucho
ruido o vibra
excesivamente
La bomba no deja de
funcionar
La bomba funciona pero
bombea muy poca agua
o no bombea agua
1. El nivel de agua es muy bajo
2. El fusible está quemado o el cortacircuito
se activó
3. El voltaje es muy bajo
4. El motor está dañado
5. El flotante está dañado
6. El impulsor (la bomba está obstruída con
basura)
7. El interruptor está obstruído
8. Nivel de líquido insuficiente
1. El agua se regresa de las tuberías
2. El interruptor/flotante está dañado
3. No instaló una válvula de chequeo o la
válvula de chequeo tiene una fuga
4. La distancia de la descarga es inferior al
mínimo recomendado por el fabricante
1. La temperatura del agua es excesiva
2. El interruptor está dañado u obstruído y
por lo tanto la bomba funciona al seco
3. El voltaje es muy bajo
1. Los cojinetes están desgastados
2. El impulsor está obstruído con basura o está
rota
3. Las tuberías que conectan la bomba al
edificio son muy rígidas o están muy flojas
1. El interruptor flotante está dañado
2. El intyerruptor flotante no se puede mover
libremente
3. Las tuberiás de descarga están obstruídas
4. Entrada excesiva de agua o la bomba no es
la adecuada para la aplicación en que se
está usando
1. El voltaje es muy bajo
2. El impulsor o la tubería de descarga están
obstruídos con basura
3. La bomba tiene alguna pieza dañada o el
impulsor está obstruído
4. La bomba está rotando en sentido
contrario
5. La bomba no es la adecuada para la aplicación
en que se está usando
6. La válvula de chequeo está atascada o
instalada incorrectamente
7. La válvula de cierre está cerrada
1. El interruptor no encenderá la bomba a menos que la bomba esté totalmente
sumergida en agua
2. Si el fusible está quemado reemplácelo con uno adecuado o reconecte
el cortacircuito
3. Si el voltaje es inferior al mínimo recomendado, chequée el alambrado
del circuito principal de la propiedad. Si es adecuado, comuníquese con
la compañía de electricidad.
4. Envie el motor al centro de servicio autorizado más cercano a su
domicilio o reemplácelo
5. Reemplace el interruptor flotante
6. Si la propela no gira, destápela y límpiela
7. Coloque el interruptor de modo que se mueva sin problemas. Reubique
la bomba si es necesario
8. Asegúrese de que el nivel de líquido sea adecuado
1. Instale una válvula de chequeo\
2. Reemplace el interruptor flotante
3. Desconecte la válvula de chequeo y revísela a ver si está bien instalada y
funcionando adecuadamente
4. Haga los cálculos una vez más para cerciorarse de que esté usando una
bomba adecuada
1. La bomba no se debe usar para bombear agua a más de 44°C (120° F).
2. Reemplace o reubique la bomba
La bomba puede comenzar a
funcionar sin previo aviso.
Desconéctela del tomacorrientes antes de darle servicio
3. Si el voltaje es inferior al mínimo recomendado, chequée el alambrado
del circuito principal de la propiedad. Si es adecuado, comuníquese con
la compañía de electricidad
1. Envie la unidad al centro de servicio autorizado más cercano a su
domicilio o reemplácelo
2. Destape la unidad, limpie el impulsor y/o reemplácelo si está roto
3. Reemplace una porción de la tubería de descarga con un conector
flexible
1. Reemplace el interruptor flotante
2. Reubique la bomba o limpie la pileta según sea necesario para que el
flotante se mueva sin problemas
3. Desconecte la bomba y limpie la bomba y las tuberías
4. Haga los cálculos una vez más para cerciorarse de que esté usando una
bomba adecuada
1. Si el voltaje es inferior al mínimo recomendado, chequée el alambrado
del circuito principal de la propiedad. Si es adecuado, comuníquese con
la compañía de electricidad.
2. Desconecte el impulsor, límpielo y cerciórese de que esté bien instalado
3. Reemplace las piezas dañadas o toda la bomba. Si es necesario limpie
las piezas que estén sucias
4. Chequée la rotación. (Sentido contrario al de las agujas del reloj al
observarlo desde la parte inferior) Devuelva la unidad si gira en el
mismo sentido de las agujas del reloj
5. Haga los cálculos una vez más para cerciorarse de que esté usando una
bomba adecuada
6. Desconecte la válvula de chequeo y revísela a ver si está bien instalada y
funcionando adecuadamente
7. Abra la válvula
!
PRECAUCION
12 Sp

Summary of content (6 pages)