Home Dehumidifier Please read the manual carefully before using the unit PD08E USER MANUAL
FOR CUSTOMERS Thank you for purchasing our dehumidifier. Waykar wishes that our products and services can bring convenience to your work and life.We highly recommend that you keep the manual for reference if you encounter unexpected events using the unit. Please read the manual carefully to ensure proper use of the dehumidifier. Our dehumidifiers are widely used in family bedrooms, bathrooms, basements, offices and storage rooms, etc.
BEFORE FIRST USE: To prevent any internal damage, it is very important to keep refrigeration units (like this one) upright throughout their journey. Please leave it standing upright and outside the box for 24 HOURS before plugging it in.
TABLE OF CONTENTS Safety Instructions Common Faults and Solutions The graphics and functions provided in this manual may not be the same as the actual product. Please always refer to the actual product. The model of the machine on the manual is for reference only. Please check the corresponding content and operate the machine based on the actual product. The right to interpret the relevant terms belongs to the company.
SAFETY INSTRUCTIONS Safety Notes: For your safety, please read the manual carefully and keep the manual before you use the manual for reference. Please use this product according to the instructions of installation and operation of this manual. Before cleaning the dehumidifier, turn off the power and unplug it from the power outlet. Please do not place the machine near any heat source or flammable goods. Always keep the machine on even surface, instead of placing on uneven or slopping ground.
Drainage Outlet Water Tank
1. Control Panel To set auto ON/OFF timer in 1-24 hrs. WATER FULL Indicator Indicates the water tank is full.
2.Setting Setting Humidity The humidity level can be set within a range of 30%RH to 80%RH in 5% increments. -When it starts to work, it will first automatically detect and show the room's humidity. Press the "SETTING" button to change the humidity selection in 5% increments. " 88 " will Flash and show the setting humidity. -Press "SETTING" to make the humidity increase OR decrease by 5%RH. -After no operation for 5s, " 88 " will show the actual room humidity.
Control the fan speed. Press to select either High or Normal fan speed. Higher fan speed will result in quicker moisture removal. Set the speed high for maximum moisture removal. When the humidity has been reduced and quiet operation is more preferred, set the fan speed back to Normal. “ " Note: In the DRY mode, the SETTING button and the SPEED button is disabled. Press the " " button until you see the CONT indicator light up on the display to select continuous mode.
More Functions Auto Shut-off When the water tank is full and or the room humidity reaches the setting value, the dehumidifier will stop working automatically. 3 Minutes Delay Protection The compressor features the "3 minutes delay protection" function— When the dehumidifier is powered, the compressor can only start again 3 minutes after its last shutdown. Auto Defrost When the dehumidifier is running at a lower temperature, the system will automatically determine whether there is a presence of frost.
3. Display Status Description When the device is currently powered on, before switching on the machine for further operations, only the power button light up. Setting light " "If the timer is set up properly, the indicator light will be up, flash if press TIMER button again to check and reset, and go out if non-successful setup. High-speed indicator light " ": If you set the unit to high speed fan mode, the indicator will light up.
5. Faults & Processing Methods Fault Phenomenon Humidity always shows "25%RH"(There is a big difference from the actual humidity) Analysis of Causes Processing Method Humidity sensor failure? Set the humidity to 30%RH, the dehumidifier can still continue to work, and can be used normally. Repair and replace the humidity sensor. The dehumidifier is not affected and can continue to work, and can be used normally.
6. Empty The Water Tank Two ways are available to remove the collected water. Use The Water Tank When the water tank is already full, the WATER FULL indicator will light up, the dehumidifier will automatically shut down until the tank has been emptied and placed back to the unit. Pull the water tank out from the bottom with both of your hands. Put the water tank back in place, the water full indicator will go out. Open the cover of the water tank. Empty the water tank.
Note: Take off the water tank cover
7.Continuous Drainage Pull out the power supply, unscrew the drainage cap, remove the black rubber plug, insert the water hose into the continuous drainage port and push it back into the water tank. Connect the power supply to start the operation. The water outlet of the water hose should be lower than the continuous drainage port by more than 3.9 inches, and the water hose cannot be bent. (Note: The diameter of continuous drainage port is 0.63 inches.
Please use a soft and slightly wet textile or cloth to clean it. 3.Slowly insert the filter back to the machine body.
, it The list includes most of the common cases, but not the results of defective unit, crafts or materials in the unit. If all troubleshooting steps have been exhausted and the issue is still occurring, please feel free to reach out to Waykar Customer Seryice to get further assistance. Is the Full Tank indicator blinking? This product does not apply to over hot or cold environment, the machine will automatically enter the protection mode. It is a normal phenomenon.
to Please leave about 20cm (7.9 inches) around the product. Do not allow enough time to remove the moisture. Room temperature is too low, or below 41℉ (5℃): The machine will not work or undergo poor dehumifying efficiency in low temperature. Please wait until the temperature rises to above 41℉ (5℃) or higher. levelly. Clean up the dirt or lint on the air outlet and intake. The Please check whether the packing bag of the filter had been removed and the filter has been installed correctly.
Connect the hose with the drainage port tightly. The water tank has not been installed properly. Re-install the water tank properly. The float of water tank has been stuck. Move the float and let it swing freely. If the dehumidifier is still not working properly as expected and the troubleshooting steps or solutions above may not resolve the issue, please unplug the power and shut down the dehumidifier, then contact Waykar Customer Service at support@waykar.com .
Do not insert thin rods and hard objects into the machine body to avoid malfunction and danger. When cleaning the dehumidifier, please use the wet textile to wipe gently, do not shoot the water directly. When continuous drainage, the drain hose must be placed horizontally, without unevenness and winding. Please clean the filter every two weeks (do not use hot water above 104°F, alcohol, gasoline or toluene.) After cleaning the filter, please do not dry it under direct sunlight, in case deformation.
MODEL POWER SOURCE PD08E 120V ~ 60Hz RATED POWER (95℉, 90%RH) 400W RATED CURRENT (95℉, 90%RH) 3.6A MOISTURE REMOVAL CARAOTY (65℉, 60%RH) 15 Pints/Day (7.13L/Day) MOISTURE REMOVAL(80℉, 60%RH) 23 Pints/Day (10.88L/Day) MOISTURE REMOVAL (86℉, 80%RH) 40 Pints/Day (18.9L/Day) MOISTURE REMOVAL (95℉, 90%RH) 50 Pints/Day (23.7L/Day) INPUT POWER (65℉, 60%RH) 216W INPUT CURRENT (65℉, 60%RH) 2.0A IEF (65℉, 60%RH) MOTOR FLA 1.30 liters/kWh 0.23A MOTOR COMPRESSOR RLA: 4.3A LRA: 9.
Warranty Waykar offers a 12-month warranty to all of our products together with the original proof of purchase when a defect occured, including those newly purchased and unused, from Waykar or through an authorized reseller, wholly or substantially, or as a result of faulty manufacturing parts, or workmanship during the Warranty Period.
We are expecting to see our products fulfill your life and hear your voice. Your satisfaction means a lot to us. Please tag us if you share a snap on your social media.