User's Manual

Wireless Smoke Alarm
(Hardwire with battery back-up)
Thank you for purchasing a Kidde Wireless Interconnect smoke alarm. It is an important part of your familys home safety plan. You
can trust this product to provide the highest level of quality and performance. We know you expect nothing less when the lives of your
family are at stake. This alarm, in combination with other Kidde Wireless products, provides you with interconnected alarms without
the inconvenience or expense of rewiring your house. In a fire, seconds count. An interconnected alarm system gives you an increased
level of safety by ensuring that all the alarms in your home activate when any one of the alarms detect a fire. Kidde estimates that the
smoke alarms in 85 million homes in the US are not interconnected. In addition, Kidde offers battery only WIRELESS alarms that
can be used to monitor additional areas while maintaining interconnect functionality, which may provide an earlier warning of a
hazardous condition. Some of the other features that are included in this unit are:
Smart Hush® allows you to quiet your alarm while taking care of a non-emergency event (see section 4).
Remote Hush® temporarily desensitizes the initiating Kidde Wireless alarm from any Kidde Wireless unit (see section 4).
Remote Push To Test that causes each Wireless unit in your system to perform a self-diagnosis whenever the test button is
pressed on any of the Kidde Wireless devices (see section 4).
Internal timer to remind you to replace your unit after 10 years to ensure the most reliable protection (see section 6).
Low Battery HUSH allows you to stop the smoke alarm from producing a low battery warning for up to twelve hours,
allowing you to maintain protection without having to replace the battery at inconvenient times such as the middle of the night.
DO NOT connect two RF-SM-ACDC alarms to a hard wire interconnected system. Doing so will result in the RF-SM-ACDC alarms
triggering each other. They will not stop alarming until one is disconnected from the electrical circuit. If your home has wired in
alarms, which are not interconnected, you can use up to twelve RF-SM-ACDC alarms.
Users Guide
Wireless, A.C. Wire-in Single and/or Multiple Station (24 devices maximum) Ionization Smoke Alarm with 9 Volt Battery Back Up
and Smart HUSH
TM
Control to temporarily silence nuisance alarms.
This alarm is interconnect compatible with the following alarms and accessories:
·Smoke alarms: 1235, 1275, 1276, 1285, 1296, PE120, PI2000, KN-COSM-I, KN-COSM-IB, RF-SM-ACDC, and RF-SM-DC
·Heat alarm: HD135F
·CO alarms: KN-COB-IC, KN-COP-IC
·Relay modules: 120X, SM120X, CO120X
·Strobe Light: SL177I
·Sound Module: RF-SND
See User’s Guides for specific application information.
This alarm detects products of combustion using the ionization technique. It contains 0.9 microcurie of Americium 241, a radioactive
material (see Section 9). Distributed under U.S. NRC License No. 32-23858-01E. Manufactured in compliance with U.S. NRC safety
criteria in 10 CFR 32.27. The purchaser is exempt from any regulatory requirements. Do not try to repair the smoke alarm yourself.
Refer to the instructions in Section 13 for service.
WARNING! REMOVAL OF THE SMOKE ALARM BATTERY AND DISCONNECTING OR LOSS
OF A.C. POWER WILL RENDER THE SMOKE ALARM INOPERATIVE.
ELECTRICAL RATING: 120 VAC, 60HZ, 15mA maximum per alarm (maximum 15mA for originating unit with 24
devices interconnected).
IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND KEEP THIS MANUAL NEAR THE ALARM
FOR FUTURE REFERENCE.
CONTENTS OF THIS MANUAL
1 -- RECOMMENDED LOCATIONS FOR SMOKE ALARMS
2 -- LOCATIONS TO AVOID
3 -- INSTALLATION INSTRUCTIONS
4 -- OPERATION AND TESTING
5 -- NUISANCE ALARMS
6 -- MAINTENANCE
RF-SM-ACDC