Datasheet

2857-550
3
140
INTERFACE ELECTRONIC
JUMPFLEX
®
Transducers
Current Transducer AC/DC 100 A
22,5 mm/0.89 in
107 mm/4.21 in
105 mm/4.13 in
Configuration via:
Interface
configuration
software
Interface
configuration
app
Configuration
display
DIP switch
Short description:
The 2857-550 Current Transducer measures AC/DC currents up to 100 A, while
converting the measured current into an analog standard signal at the output.
Features:
Both digital signal output and relay with changeover contact react to configured
measuring range limits (switching ON/OFF delay and threshold value switch
function configurable with up to two threshold values).
Clipping capability provides analog signal limitation to output end values.
Adjustable software filter
Input/Output response simulation via configuration display
Safe 3-way isolation with 4 kV test voltage acc. to EN 61140
Description
Item No.
Pack.
Unit
JUMPFLEX
®
Transducer, for DIN 35 rail 2857-550 1
Current Transducer AC/DC 100 A
Technical Data
Configuration:
Configuration DIP switch, interface configuration
software, interface configuration app,
configuration display
Input:
Input signal AC/DC 100 A
Response threshold 10 mA (DC) / 500 mA (AC)
Resolution 10 mA
Frequency range 15 Hz … 1000 Hz
Output:
Output signal
Current:
± 10 mA; 0 … 10 mA; 2 … 10 mA;
± 20 mA; 0 … 20 mA; 4 … 20 mA
Voltage:
± 5 V; 0 … 5 V; 1 … 5 V;
± 10 V; 0 … 10 V; 2 … 10 V
Overcurrent 0% or +5% (e.g., 10.5 V / 24 mA)
Measuring range overflow/underflow 0% or +2.5%
Load impedance Current: ≤ 600 Ω; Voltage: ≥ 1 kΩ
Measuring procedure True RMS measurement (TRMS) or
Arithmetic mean value
Output – Digital:
Max. switching voltage Supply voltage applied -0.3 V
Output – Relay:
Contact type 1 changeover contact (1 u)
Contact material AgNi (gold-plated)
Max. switching voltage 250 VAC
Max. continuous current
(terminal blocks in a row) 6 A (up to 60 °C), 3 A (60 °C … 70 °C)
Dielectric strength open contact (AC, 1 min)
1 kV
rms
Pull-in/drop-out/bounce time typ. 8 ms / 4 ms / 8 ms
Max. continuous current I
DO
100 mA (no internal restriction)
General specifications:
Supply voltage U
S
24 VDC
Supply voltage range 16.8 V … 31.2 V (-30 % … +30 %)
Current consumption at 24 VDC ≤ 50 mA (+ I
DO
)
Technical Data
General specifications:
Max. operating frequency 3.3 kHz
Response time Signal cycle duration + 1 ms
Response time (T
10-90
) max. 60 ms
Filter (T
10-90
) Software filter: 600 ms
Linearity error ≤ 1 %
Measurement error ≤ 0,2 % (bezogen auf Messbereichsende)
Temperature coefficient ≤ 0.01 %/K
Environmental requirements:
Ambient operating temperature -40 °C … +70 °C
Storage temperature -40 °C … +85 °C
Safety and protection:
Test voltage (input/output/supply) 2.5 kV AC, 50 Hz, 1 min.
Test voltage
(measuring circuit – output) 4 kV AC, 50 Hz, 1 min.
Connection and type of mounting:
Wire connection CAGE CLAMP
®
S (picoMAX
®
5.0)
Cross sections solid/fine-stranded:
0.2 … 2.5 mm² / AWG 24 … 12
Strip length 9 … 10 mm / 0.35 … 0.39 in
Power cable feed-through Ø 9.5 mm
Recommended measurement conductor cross-section
16 mm²; max. 25 mm²
Dimensions and weight:
Dimensions (mm) W x H x L 22.5 x 107 x 105
Height from upper-edge of DIN 35 rail
Weight 106 g
Standards and approvals:
Conformity marking 1
Standards/Specifications DIN EN 61010-1:2010;
DIN EN 60664-1:2008; Safe isolation
acc. to DIN EN 61140:2002;
IEC 61000-6-2; IEC 61000-6-4
Accessories: For accessories, see Full Line Catalog
INTERFACE ELECTRONIC 2012/2013
WAGO Kontakttechnik GmbH & Co. KG
Subject to design changes 30.10.2013
Postfach 2880 - D-32385 Minden
Hansastr. 27 - D-32423 Minden
Tel.: +49(0)571/887-0 E-Mail: info@wago.com
Fax: +49(0)571/887-169 www.wago.com

Summary of content (2 pages)