SPECIFICATION
MDR-10-5 MDR-10-12 MDR-10-15 MDR-10-24
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.5
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING HUMIDITY
WORKING TEMP.
DC OK ACTIVE SIGNAL (max.)
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
5V 12V 15V 24V
2A 0.84A 0.67A 0.42A
0 ~ 2A 0 ~ 0.84A 0 ~ 0.67A 0 ~ 0.42A
10W 10W 10W 10W
80mVp-p 120mVp-p 120mVp-p 150mVp-p
±5.
0% ±3.0% ±3.0% ±2.0%
±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±3.0% ±3.0% ±2.0%
500ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load
120ms/230VAC 25ms/115VAC at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
77%
81% 81% 84%
0.33A/115VAC 0.21A/230VAC
COLD START 35A/115VAC 70A/230VAC
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
3.75 ~ 6V / 50mA
Protection type : Shut down o/p voltage, re-power on to recover
13.8 ~ 16.2V
9 ~ 13.5V / 40mA
17.25 ~ 20.25V
11.5 ~ 16.5V / 40mA
27.6 ~ 32.4V
18 ~ 27V / 20mA
-20 ~ +70 (
Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85, 10 ~ 95% RH
±0.03%/ (0 ~ 50)
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
584K hrs min. MIL-HDBK-217F (25)







File Name:MDR-10-SPEC 2013-11-26
UL508, TUV EN60950-1 approved
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024,EN61000-6-1,EN61204-3, light industry level, criteria A
10W Single Output Industrial DIN Rail Power Supply
MDR-10 series
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
PROTECTION
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE










22.5*90*100mm (W*H*D)
0.17Kg; 72pcs/13.2Kg/0.91CUFT
LEAKAGE CURRENT
<1mA / 240VAC
FUNCTION
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
..
EMC IMMUNITY
EMC EMISSION

Summary of content (2 pages)