CA80 Series Vari-Angle IR Illuminator Installation Guide Rev. 1.3 QIG Part no.
Revision History: * Rev. 1.0: Initial Release * Rev. 1.1: Replace U-Bracket * Rev. 1.2: Revise Mechanism Error * Rev. 1.3: Revise Mechanism Content Package Contents X4 X2 LED 100% On/Off 75% X2 LED Status 50% 50% 25% 20% T Dimming Zoom 10% W The 1/4" screws and washers are used to secure the illuminator to an external camera housing. NOTE: • The wall-mount (CMA-B04), laser alignment kit (CMA-A01), remote controller (CMA-E01), and other accessory are separately purchased.
RISK GROUP 3 WARNING IR emitted from this product, Do not look at operating lamp. IR illuminators RISK GRORP 3 / WARNING IR emitted from this product. / Avoid eye exposure. Use appropriate shielding or eye protection. Do not look at operating lamp. Class III luminaires Do not stare at the operating light source. This marking indicates that this product should not be disposed with other household wastes throughout the EU.
Mechanical Drawings Standard bracket StandardSmall Small U U bracket 50 9.85 220mm(8.66") 18.5 134 9.5 24 5.9 54 46 3 20 M6x1 27.4mm(1.08") 69.4mm(2.73") 90mm(3.54") 50mm(1.97") 160mm(6.3") 69.4mm(2.73") .2 n6 31 3 23 236mm(9.3") R60 15 ~ 6.2 24 48 25 73mm(2.87") 49mm(1.93") 90 43mm(1.7") 36 93.4mm(3.68") 117.4mm(4.
II Installation IMPORTANT: It is highly recommended that the illuminator should be installed at a position higher than 3 meters from the ground. You must first survey the installation site and determine the illumination distance. Use the remote controller to adjust the beam angle. The factory default for the beam angle selector is always at the Widest angle. Refer to the tables below for the configurable IR light beam angles and the definitions of the remote controller buttons.
Cable Pinouts Name V+ VDI+ Color Red Black Green Gauge (20AWG) (20AWG) (26AWG) DIDO+ Yellow Purple (26AWG) (26AWG) DOBlue RS485+ Orange RS485- Brown (26AWG) (26AWG) (26AWG) Description Power input (AC/DC 24V ±10% current controlled) LED ON/OFF control * Dry contact Logic level 1(Open) = LED off Logic level 0(Close to GND) = LED on * Wet contact Logic level 1: 4V~40 V = LED off Logic level 0: 0.8V MAX = LED on Ground Light sensor status output 1. Open = Day 2.
Coordination with Cameras via the DI and DO Pins +3.3V Light sensor status output (Purple & Blue wires) +3.3V R R This mode means that camera Day/Night mode switching DI+ R Switch GND GND GND is coordinated with and is triggered by the illuminator's light DI- sensor via the DO(Digital output) connection (connected to +3.3V the camera's DI pins). Users can configure the camera R Fuse/50mA DO+ External power source configuration to control the corresponding illuminator On/Off status.
This page is intentionally left blank.