MI NOTICE !xxxx0! 21837618-7 X0 GB.doc 1 02/03/06 Johnson Controls Inc.
GENERAL SAFETY PRECAUTIONS • Ensure you read the following instructions carefully. • Follow all the warnings and instructions shown on the products. The International Electrical Symbols used on the device and in this notice are explained in table 1 at the end of this document. • Disconnect the equipment from the wall socket before cleaning. Do not use cleaning fluids or aerosols. Use a slightly damp cloth for cleaning. • This equipment must only be used with the battery and mains adapter supplied by us.
• Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
• IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Content 1- Description ........................................................................................................ 8 1-1 Probe..........................................................................................................................8 1-2 Probe supply ..............................................................................................................8 2- Use .................................................................................................................
1- Description 1-1 Probe USB connector to PC Mains adapter connector USB HUB output Not used MI synchronization cable connector Power LED Power switch Communicatio n LED Self battery contained LED Operation in progress LED Connectors for measurements Not used 1-2 Probe supply The probe may be supplied by: - The battery of the vehicle via the MI synchronization cable - The self contained battery - The mains adapter only to charge the self contained battery 8
2- Use Warning When working with voltages greater than 33 V RMS, 46 V peak or 70V continuous, take care as these voltages pose a risk of electrocution. Use MI in accordance with the following instructions: • ensure it is powered only by the internal battery, • connect it to the central diagnostic unit using Bluetooth mode only, • disconnect all other USB leads, MI synchronization lead… • cover over all connector openings using the rubber covers provided for this purpose.
2-1 Connection diagram Mains adapter cable To mains Test pins and crocodile clips MI synchronization cable To vehicle for Power Supply 10 USB cable To vehicle for taking measurement
3- technical specifications 3-1 Equipment environment Mains adapter: Input: 100-240V AC 1A 50-60Hz Output: 12V DC 1.67A The removable plug for the mains power distribution board is used as a breaker device for the mains power source. This mains adapter is used only to charge the MI self contained battery. MI Probe: Input: 8-16V DC Imax 2.5A Battery: Type Li Ion 3.2V 2200mAH Battery life: 1hour 30 minutes at 25°C .
4- Maintenance Any operation other than replacement of the battery must be carried out by an after sales service technician who is qualified to do so and knows the risks involved Only use the accessories and consumables supplied by us: measuring cables, connectors, spare battery. 4-1 Battery: Warning Do not reverse, incinerate or mutilate battery. This can cause toxic material or gas leakage and/or explosion.
4-1-2 Recharging the battery The battery must ONLY be recharged using the charger integrated into the MI. Just connect the probe to the mains using the mains power adapter or to the car using the MI synchronization cable (refer to the connection diagram). Make sure you observe the recharge temperatures shown in the technical specifications. 4-2 Scrapping the battery The battery must not be thrown away. It must be returned to the manufacturer for recycling.
8- International electrical symbols DC (Direct current) AC (Alternating current) AC or DC Earth ground Warning, refer to the notice for information Warning against electrical choc Double insulated 7- After sales service In the event of any problems, please contact your Johnson Controls Inc. representative. Johnson Controls Inc. Service après-vente 1, Avenue Pierre-Gilles de Gennes Z.I. des Ajeux 72400 La Ferté-Bernard France Tel.