Dual-Technology Microwave/PIR Intrusion Detectors
Installation Instructions
)($785(6
Cylindrical optics improves detection and false alarm immunity.
True Motion Recognition™ (TMR) algorithm (patented) distin-
guishes between the true motion of a human body and other
disturbances which invariably cause false alarms
DRO-stabilized MW microstrip technology (patented)
MW Motion Simulator simulates the effect of a human body
moving in the MW field (for MW self-test - patent pending)
Range control for adjusting the MW coverage
Integral swivel bracket for wall or ceiling installation
Sealed chamber protects the pyroelectric element from insects.
PIR self-test by applying a short heat pulse (LOGICA-AM only)
Programmable motion event
counter (1 or 2 events)
Simple-to-use, two-position
vertical adjustment
TEST input to enable/disable
the walk test LED remotely
(per new European standard)
Open collector trouble output
Anti-masking protection
(LOGICA-AM only)
White light protection.
Figure 1. General View
63(&,),&$7,216
Input Voltage: 9 to 16 VDC
Current Drain: About 28 mA @ 12 VDC
PIR SECTION
Detector: Low noise dual-element pyroelectric sensor
Tripping Indication: LED flashes green for up to 5 seconds
Motion Event Verification Counter: Selectable, 1 or 2 events
Lens Data (No. 105DH - see Figure 2)
No. of Beams: 36 in two layers (curtain beams in bottom layer)
Max. Coverage: 12 x 12 m (40 x 40 ft) / 90
field of view
Vertical Adjustment: FAR and NEAR, by sliding the circuit board
along a two-position scale.
MW SECTION
Oscillator: Microstrip DRO-stabilized Doppler module
Frequency: 10.525 or 2.45 GHz
Detection Range: Adjustable from 25% to 100% (3 m to 12 m)
Tripping Indication: LED glows green for up to 5 seconds
ALARM, TAMPER & TROUBLE DATA
Alarm Indication: LED glows red for 1.3 to 5 seconds if both
detectors trip
Relay Contacts: N.C., rated at 0.1 A resistive / 30 VDC; 18
resistor in series with contacts
Alarm Duration: 1.3 to 5 seconds
Tamper Switch: N.C., rated at 50 mA resistive / 30 VDC
Trouble Output: Open collector, 100 mA max., with 18
resistor
in series and 47 k
pull-up (see Figure 11)
Masking Detection Delay (LOGICA-AM only): About 60 seconds
Trouble/ Masking Indication: LED alternately flashes green and
red and TRB output pulls LOW until the detector is reset.
MOUNTING
Height: Up to 3.6 m (12 ft)
Room Size: 8 - 12 m (24 -
40 ft) in the “FAR” position;
2 - 8 m (6 - 24 ft) in the NEAR
position.
Bracket Adjustment: 20
downward, 20
left and right.
Installation Options: Surface
or corner (without bracket);
surface or ceiling (with bracket)
ENVIRONMENTAL
RFI Protection: >30 V/m up to
1000 MHz.
Operating Temperatures:
-10
C to 50
C (14
F to 122
F).
Storage Temperatures: -20
C
to 60
C (-4
F to 140
F).
Figure 2. Coverage Pattern
Compliance with Standards: Complies with Part 15 of the FCC
Rules. Meets the European Council Directive EMC 89/336/EEC &
92/31/EEC, and bears the CE mark and certification.
PHYSICAL
Size (H x W x D): 117 x 65 x 47 mm (4-5/8 x 2-9/16 x 1-7/8 in.).
Weight: 109 g (3.85 oz) without bracket, 124 g (4.4 oz) with
bracket.
PATENTS
U.S. Patents 5,237,330 and 5,693,943 (other patents pending)
,167$//$7,21
,QVWDO ODWLRQ+LQW V
To minimize false alarms:
Do not aim at heat sources
Mount on solid, stable surfaces
Do not expose to air drafts Do not install outdoors