User's Manual

GB-502 PG2
Wireless PowerG Two-Way Acoustic Glass-break Detector
Abbreviated Installation Instructions
D-305844 GB-502 PG2 Installation Instructions 1
Introducing GB-502 PG2
The GB-502 PG2 is a wireless PowerG Two-way acoustic glass-break
detector designed to detect the breaking of framed glass mounted in an
outside wall. This detector is wall/ceiling mountable and suitable for most
types of window/door glass: plate, tempered, laminated, wired, coated and
sealed insulating glass. No adjustment is necessary during installation the
detector is fully pre-calibrated.
The coverage range also depends on the angle between the detector and
the glass for a higher angle, the maximum range is reduced.
For the complete GB-502 PG2 Installer Guide, go to
http://www.visonic.com/download-center.
Alternatively, contact us at info@visonic.com to request the complete ver-
sion of the installation guide.
1. Inserting the Battery
1. Press in the snap and separate the cover from the base.
2. Insert the battery into the battery clips.
Observe Polarity!
Caution! Risk of explosion if battery is replaced by
an incorrect type. Dispose of used battery according
to manufacturer's instructions.
2. Mounting the Device
1. Fasten the breakaway segment to the wall.
Attention! The GB-502 PG2 has a back tamper switch under the
PCB. As long as the PCB is seated firmly within the base, the switch
is pressed against a special break-away base segment that is loosely
connected to the base. Be sure to fasten, using screw C, the break-
away segment to the wall. If the detector unit is forcibly removed
from the wall, this segment will break away from the base, causing
the tamper switch to open!
2. Put back the cover on the base and secure with screw.
For mounting the device with a bracket, refer to the BR-1, BR-2, or BR-3
Installation Instructions.
3. Enrollment of the Device
Refer to the PowerMaster panel's Installer Guide and follow this procedure
under the "02:ZONES/DEVICES" option of the Installer Menu.
02.ZONES/DEVICES ð
ADD NEW DEVICES ð
ENROLL NOW or
ENTR ID:XXX-XXXXð
Z04:Glass Break
ID No. 160-XXXX ð(with panels PowerG V.19.1 & lower)
ID No. 161-XXXX ð(with panels PowerG V.19.2 & higher)
Z06.LOCATION
Z06.ZONE TYPE
4. Local Diagnostics Test
Procedure
Before testing, separate the base from the cover.
The following table indicates the received signal strength.
LED response Reception
Green LED blinks Strong
Orange LED blinks Good
RED LED blinks Poor
No blinks No communication
IMPORTANT! Reliable reception must be assured. Therefore, "poor" signal
strength is not acceptable. If you receive a "poor" signal from the device, re-
locate it and re-test until a "good" or "strong" signal strength is received.
Note: For detailed Diagnostics Test instructions refer to the control panel
Installer Guide.
5. Testing Procedures
Switching the Sensor to the Test Mode
After power-up or closing the cover, the detector will automatically enter a
15 minute test mode. For remote switching of the detector to test mode
(via User or Installer Code), refer to the PowerMaster Installer Guide,
Chapter 6, Periodic Test.
Testing the Sensor
A. Basic Test
Test the detector's low frequency (FLEX) respons by thumping the pro-
tected glass with a cushioned object. The green LED will light for 2
seconds. Repeat the test if necessary.
B. Extended Glassbreak Simulation Test (optional)
See the complete installation guide for details.
6. Installation Tips
l The GB-502 PG2 detects the shattering of framed glass mounted
on an outside wall. Testing the sensor with unframed glass, broken
bottles, etc. might not trip the sensor. False alarms such as glass
breaking in the middle of a room will not activate the sensor.
l False alarms are most likely to occur when installed on a 24-hour
loop, in glass airlocks, and glass vestibule areas. Similarly, when
mounted above sinks, residential garages, and in other small
acoustic live rooms, false alarms can be generated. In rooms
where multiple sounds can reflect and eventually duplicate the
glass break frequency pattern, use shock sensors.
l Installing the GB-502 PG2 on 24-hour loops will increase false
alarms. Install the GB-502 PG2 on a perimeter loop, which is
armed whenever the door and window contacts are armed. For
occupied areas, GB-502 PG2 false alarm immunity is best in rooms
with only moderate noise levels.
l GB-502 PG2 detects the shattering of glass. Like all glass-break
sensors, the detector might not consistently detect cracks in glass,
or bullets that break through or break out the glass. Glass-break
sensors should always be backed up by interior protection.
7. Event Indications
LED Indications and Events
LED Response Description
Red LED blinks Stabilization (warm-up 8 sec)
Red LED ON 0.2 sec. Tamper open / close
Red LED ON 2 sec. Glass break alarm
Green LED ON 2
sec.
Low frequency detection Test mode
Green and red LED
blink alternately
Self-test failure Test mode
Green and red LED
blink alternately
slowly
Self-test failure Normal mode
8. Compliance With Standards
The GB-502 PG2 complies with the fol-
lowing standards:
Europe: EN 300220, EN 301489, EN50130-4,
EN60950, EN50130-5, EN 50131-2-7-1, EN
50131-1 Grade 2 Class II
This device complies with the essential require-
ments and provisions of Directive 1999/5/EC of
the European Parliament and of the Council of 9
March 1999 on radio and telecommunications
terminal equipment.
USA: CFR 47 Part 15 (FCC)
Canada: RSS 210
USA: UL639
Canada: ULC-S306
WARNING! Changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the user’s authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules and with Industry
Canada license-exempt RSS standard(s). Operation is subject to the fol-
lowing two conditions: (1) This device may not cause harmful inter-
ference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Le present appareil est conforme aux CNR d'Industrie Canada applic-
ables aux appareils radio exempts de licence. L'exploitation est autor-
isee aux deux conditions suivantes :(1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radi-
oelectrique subi, meme si le brouillage est susceptible d'en com-
promettre le fonctionnement.
To comply with FCC Section 1.1310 for human exposure to radio fre-
quency electromagnetic fields and IC requirements, implement the fol-
lowing instruction:
A distance of at least 20cm. between the equipment and all persons
should be maintained during the operation of the equipment.
W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must
contact the company from which you originally purchased it. If
you are discarding this product and not returning it for repair
then you must ensure that it is returned as identified by your
supplier. This product is not to be thrown away with everyday
waste.
Directive 2002/96/EC Waste Electrical and Electronic Equipment.
The Power G peripheral devices have two- way communication func-
tionality, providing additional benefits as described in the technical brochure.
This functionality has not been tested to comply with the respective tech-
nical requirements and should therefore be considered outside the scope
of the product’s certification.
Specifications
Frequency Band
(MHz)
Current Con-
sumption
Europe and rest of world: 433-434, 868-869
USA: 912-919
23µA average quiescent, maximum 150mA
Power Supply
3 V Lithium CR-123 type battery, Panasonic or GP
only
Battery Life 5 years (for typical use)
Operating Tem-
perature
-10°C to 50°C (1F to 120°F) indoors
Humidity
5 % to 95 % with no condensation
Maximum Detec-
tion Range
7.6 m (25 ft) if glass size is minimum 40 x 40 cm (15
¾ x 15 ¾”).
6 m (20 ft) if glass size is 30 x 30 cm (12 x 12”) to
40 x 40 cm (15 ¾ x 15 ¾”)
Glass Types
UL tested on: Plate, tempered, wired, laminated,
covered, and sealed insulated
EN tested on: Plate and wired
Minimum Glass
Size
UL tested on:30 x 30 cm (12 x 12”)
EN tested on: 40 x 40 cm (15 ¾ x 15 ¾”)
Room Size
Not larger than 12 x 12 m (36 x 36 ft);
Not smaller than 3 x 3 m (10 x 10 ft).
Min. Distance from
Glass
1.5 m (5 ft)
Brackets
BR-1: Surface mounted swivel bracket, adjustable
30° down and 45° left/45° right.
BR-2: BR-1 with a corner adapter
BR-3: BR-1 with a ceiling adapter
Dimensions
88 x 62 x 30 mm (3.5 x 2.4 x 1.2 in.)
Weight (not includ-
ing battery)
74 g (2.6 oz)
WARRANTY
Visonic Limited (the Manufacturer") warrants this product only (the
"Product") to the original purchaser only (the Purchaser”) against defective
workmanship and materials under normal use of the Product for a period
of twelve (12) months from the date of shipment by the Manufacturer.
This Warranty is absolutely conditional upon the Product having been prop-
erly installed, maintained and operated under conditions of normal use in
accordance with the Manufacturers recommended installation and oper-
ation instructions. Products which have become defective for any other
reason, according to the Manufacturers discretion, such as improper install-
ation, failure to follow recommended installation and operational instruc-
tions, neglect, willful damage, misuse or vandalism, accidental damage,
alteration or tampering, or repair by anyone other than the manufacturer,
are not covered by this Warranty.
There is absolutely no warranty on software, and all software products are
sold as a user license under the terms of the software license agreement
included with such Product."
The Manufacturer does not represent that this Product may not be com-
promised and/or circumvented or that the Product will prevent any death
and/or personal injury and/or damage to property resulting from burglary,
robbery, fire or otherwise, or that the Product will in all cases provide
adequate warning or protection. The Product, properly installed and main-
tained, only reduces the risk of such events without warning and it is not a
guarantee or insurance that such events will not occur.
Conditions to Void Warranty: This warranty applies only to defects in
parts and workmanship relating to normal use of the Products. It does not
cover:
* damage incurred in shipping or handling;
* damage caused by disaster such as fire, flood, wind, earthquake or
lightning;
* damage due to causes beyond the control of the Seller such as
excessive voltage, mechanical shock or water damage;
* damage caused by unauthorized attachment, alterations, modi-
fications or foreign objects being used with or in conjunction with the
Products;
* damage caused by peripherals (unless such peripherals were supplied
by the Seller;
* defects caused by failure to provide a suitable installation environment
for the products;
* damage caused by use of the Products for purposes other than those
for which they were designed;
* damage from improper maintenance;
* damage arising out of any other abuse, mishandling or improper
application of the Products.
Items Not Covered by Warranty: In addition to the items which void the
Warranty, the following items shall not be covered by Warranty: (i) freight
cost to the repair centre; (ii) customs fees, taxes, or VAT that may be due;
(iii) Products which are not identified with the Seller's product label and lot
number or serial number; (iv) Products disassembled or repaired in such a
manner as to adversely affect performance or prevent adequate inspection
or testing to verify any warranty claim. Access cards or tags returned for
replacement under warranty will be credited or replaced at the Seller's
option.
THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL
OTHER WARRANTIES, OBLIGATIONS OR LIABILITIES, WHETHER
WRITTEN, ORAL, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR
OTHERWISE. IN NO CASE SHALL THE MANUFACTURER BE LIABLE TO
ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR
BREACH OF THIS WARRANTY OR ANY OTHER WARRANTIES
WHATSOEVER, AS AFORESAID.
THE MANUFACTURER SHALL IN NO EVENT BE LIABLE FOR ANY
SPECIAL, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR PUNITIVE
DAMAGES OR FOR LOSS, DAMAGE, OR EXPENSE, INCLUDING LOSS OF
USE, PROFITS, REVENUE, OR GOODWILL, DIRECTLY OR INDIRECTLY
ARISING FROM PURCHASERS USE OR INABILITY TO USE THE
PRODUCT, OR FOR LOSS OR DESTRUCTION OF OTHER PROPERTY
OR FROM ANY OTHER CAUSE, EVEN IF MANUFACTURER HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH,
PERSONAL AND/OR BODILY INJURY AND/OR DAMAGE TO PROPERTY
OR OTHER LOSS WHETHER DIRECT, INDIRECT, INCIDENTAL,
CONSEQUENTIAL OR OTHERWISE, BASED ON A CLAIM THAT THE
PRODUCT FAILED TO FUNCTION. HOWEVER, IF THE MANUFACTURER
IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS
OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY, THE
MANUFACTURER'S MAXIMUM LIABILITY (IF ANY) SHALL NOT IN ANY

Summary of content (14 pages)