Installation Instructions

10
Electrical Requirements
Electrical Requirements
Check your local codes regarding this unit.
This cooktop is supplied with a 3-wire, A.C.
208Y/120 volt or 120/240 volt, 60 HZ electrical
system. A white (neutral) is not needed for this
unit. See next section for grounding
instructions. It should be fused separately.
Refer to the specifications chart and the
identification label on the bottom of the
burner box for kilowatt rating and
recommended amperage. House wiring and
fusing must comply with local codes. If no
local codes are applicable, wire in accordance
with the National Electrical Code, ANSI/NFPA-
70 – latest edition.
Electrical Connection
When making the wire connections, use
the entire length of the conduit provided
(3 feet). The conduit must not be cut. Connect
the red and black leads from the unit conduit
to the corresponding leads in the junction box.
The bare ground wire in the conduit is
connected to the unit frame. When connecting
to a 3-conductor branch circuit, if local codes
permit, connect the bare ground connector
lead of the unit to the branch circuit neutral
(gray or white in color).
WARNING
The electrical power to the
unit must be shut off while line
connections are being made.
Failure to do so could result
in serious injury or death.
WARNING
FIRE AND ELECTRICAL
SHOCK HAZARD
DO NOT use an extension
cord with this appliance. Such
use may result in fire, electrical
shock, or other personal injury.