E. Timing/Dialing Options (Memory Location #18)
There are six positions in the timing/dialing options. To program these options, enter the six desired timing/dialing dig-
its followed by #18. The six available timing/dialing options are defined as shown below.
Dial:A+B+C+D+E+F+#+1+8
Factory Default Setting: 2 + 3 + 4 + 1 + 1 + 1
Talk/Listen Delay
Call Length
Silence Time Out
Dial Next Number on Ring No Answer
Dial Next Number on Busy
Pulse Dial Speed
Enter Timing/Dialing Settings Here:
A B C D E F
#18
Setting A - Talk/Listen Delay
This feature selects switching time between talk and listen modes
(VOX switching time). Use chart at the right. * Note: The factory
default is .2 seconds.
Setting B - Call Length Time Out
This feature selects the maximum length of time that calls can be connected. Programmable
in increments of 1 minute up to a maximum of 9 minutes (Touch Tones 1 - 9). Program 0 in
this location to disable the call length time out. With the call length disabled, the E-30 phone
must rely on CPC, busy, silence or return dialtone to hang-up. Use chart at the far right.
*Note: The factory default is 3 minutes.
Touch
Tone
1
2
3
4
5
6
7
8
9
Talk/Listen
Delay
.1 sec
.2 sec *
.3 sec
.4 sec
.5 sec
.6 sec
.7 sec
.8 sec
.9 sec
Touch
Tone
0
1
2
3
4
5
6
7
8
9
Call Length
Time Out
Disabled
1 min
2 min
3 min*
4 min
5 min
6 min
7 min
8 min
9 min
D. Speed Dial Numbers (Memory Locations #00 - #04)
Note: Up to 20 digits can be stored in each dial position. Special features such as pause, mode change, Touch Tone
,
and # count as single digits.
The speed dial number programmed in location #00 is the telephone or extension
number that is dialed when the “Call” button is first pressed. Additional speed dial
numbers will be dialed when there is no answer or a busy signal is detected and the
next number redial features are activated. The E-30 will cycle through the pro-
grammed speed dial numbers until answered. To program, enter the desired speed
dial number followed by the memory location number (#00 - #04).
To clear a speed dial location, simply enter the memory location (#00 - #04) alone.
The E-30 is factory set with no speed dial number programmed.
To Program:
,
#
4 second pause
switch to pulse mode
0, 1, 2...9
Enter:
,,
,#
,7
,6
0, 1, 2...9
B. Quick Programming Features
First speed dial number ...........................................................................................
Second speed dial number ......................................................................................
Third speed dial number ..........................................................................................
Fourth speed dial number ........................................................................................
Fifth speed dial number ...........................................................................................
To add a
, at any point in the dialing string ...............................................................
To add a # at any point in the dialing string ...............................................................
To add a four second pause at any point in the dialing string ....................................
Toggle between Touch Tone and Pulse dialing .........................................................
Timing/Dialing options (factory set to 23411) ...........................................................
Change security code (factory set to 845464) .........................................................
0-20 digits
0-20 digits
0-20 digits
0-20 digits
0-20 digits
,,
,
#
,7
,6
6 digits (0-9)
6 digits (0-9)
#00
#01
#02
#03
#04
#18
#19
Enter Digits
then
then
then
then
then
then
then
- then -
Enter Memory Location
C. Security Code (memory location #19)
The security code allows the user/installer to program the E-30 phone while DIP switch 3 is in the ON (normal) posi-
tion. The factory set security code is 845464 (V-I-K-I-N-G). It is recommended that the factory set security code be
changed. Example: To store 123456 as the security code:
Enter Your Security Code Here:
#19
Step 1. Access programming as shown is Programming section A.
Step 2. Enter 123456 #19..
Step 3. Hang-up.
Note: The security code must be 6 digits and cannot include a
,