Step 1. Move DIP switch 2 to the ON position (sets unit to answer incoming calls - see section E).
Step 2. From a Touch Tone phone call the line attached to the E-30.
Step 3. When the E-30 answers, enter the 6-digit security code (factory set to 845464 - see section B). A double beep
should then be heard indicating you have entered the programming mode.
2. Without the Security Code
A. Accessing the Programming Mode
1. Using the Security Code
Step 1. Move DIP switch 2 to the ON position (sets unit to answer incoming calls - see section E).
Step 2. Move DIP switch 3 to OFF (incoming calls enter the programming mode without security code - see section E).
Step 3. From a Touch Tone phone call the line attached to the E-30.
Step 4. When the E-30 answers, a double beep will be heard and you will automatically enter the programming mode.
Step 5. When finished programming, move DIP switch 3 back to the ON position (see section E).
Note: If a valid memory position is entered, a double beep will be heard, four beeps indicate an error.
Front View of Optional
VE-5x5 (not included)
2.25”
Condensation
Drain Hole
Adhere gasket to front panel,
centering over mounting holes
5.14”
5.22”
3.25”
Call
3.63
Typical
Carlon PVC
Electrical Box (part #
E989NNJ - included)
Rear View of VE-5x5
(not included)
3.0” 3.3”
3.0”
Push to Call Button
Red Off-Hook LED Indicator
(4) 6-32 X 3/4” stainless steel, flat
head, hexdrive, screws (included)
Condensation Drain Hole
5.0”
(4) 0.38” diameter
(for gooseneck mounting)
(2) 0.2 x 0.43 slots
(1) 0.74" diameter
The optional VE-5x5 Surface Mount Box is designed to be
surface mounted to a single gang box or pedestal (right).
Important: The E-30 will
NOT mount to a standard
double gang box.
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the
telephone line. It is recommended that a surge protector be installed to protect against such surges. Contact Panamax at (800)
472-5555 or Electronic Specialists Inc. at (800) 225-4876.
3
Shown with
American Access
System's Gooseneck
(303) 799-9757
Caution: When warm air comes in contact with cold surfaces, such as outside walls and conduits, it causes condensation. To prevent
condensation from accumulating inside the E-30 always bring conduit into the bottom of the unit. If this is not possible, drill a 1/4” diam-
eter hole in the bottom of the gray plastic box.
Note: When using the large foam gasket (flush mounting), peel off paper liner and adhere gasket to the back of the faceplate, centering
it over the four corner mounting holes. Be careful to position the modular jack inside the chassis as not to
damage the components on the circuit board.
C
9
C9
1
2
3
4
5
6
7
8
9
10
or
C.O. Line
Analog
PABX/KSU
Station
3.63”
3.63” Typical
C
9
C9
1
2
3
4
5
6
7
8
9
10
or
C.O. Line
Analog
PABX/KSU
Station
3.63”
3.63” Typical
Gell-Filled
Tip and Ring
Connectors
(included)
Rear View of the
Standard E-30
Red
Green
Rear View of the
E-30-EWP
RJ11
?
?
Need More Information on the VE-5x5?
Call (715) 386-4345 and select 424.
?
?
Need More Information on EWP?
Call (715) 386-4345 and select 859.
!
?
?
Need More Information on the DLE-200B?
Call (715) 386-4345 and select 605.
The E-30 phone can be programmed from any Touch Tone phone using a C.O. line, analog PABX/KSU station, or a
DLE-200B Line Simulator.