Installation manual

Page 4 TYPE 115
Viking W-1000 Wiring
Wiring into Unused CO Port on KSU - with Essex Gate Control System -
AC Out For Strike
VIKING Model C-1000B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
EARTH GND
PHONE LINE INPUT
LINE OUT TO PHONES
KEYLESS CONTACT
DOOR BOX 1
DOOR BOX POWER
DOOR BOX 2
DOOR STRIKE 1
DOOR STRIKE 2
TALK
OFF
BATT
ON
1 2 3
C
O
M
N.
O.
N.
C.
1
KSU
13.8 VAC
1.25A
13.5 VAC IN
Holovision Face Plate shown
with W-1000 installed
“Talk Battery” is ON
When used w/o CO line
ON
OFF
Essex Model 265
NC 2
NO 2
COM 2
NC 1
NO 1
COM 1
DC
OUT
AC
IN
Remote
Monitor
Earth
Remote Bypass Button
Gate Strike with MOV
MOV is recommended
Keypad Cable
16.5 VAC
40 VA
Relay Out to Essex Controller
DO NOT CONNECT CO
LINE IN
NOTE 1: Remove the jumper wire & MOVs from left side terminal strip. Wire right side terminal strip
“color for color”.
NOTE 2: MOV (metal oxide varistor) is the small red component which is included. Its purpose is to
absorb “inductive kick back” which can be created when power is removed from the strike.