EN Manual BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC900300000
EN Contents 1.Important safety instructions ………............ 2 2. Installation ..................................................... 2 3.Product features............................................. 3 3.1 General .................................................... 3 3.2 Display .................................................... 5 3.3 Buttons.................................................... 6 4. Monitoring...................................................... 6 5. Full setup details ..................
1. Important safety instructions Read all instructions before starting the installation. Keep the controller away from rain, exposure, severe dust, vibration, corrosive gas and intense electromagnetic interference. 2. Installation Please see section 8 for mounting dimensions Connection to the BlueSolar PWM-Pro charge controller: The panel must be connected to the controller with a standard RJ45 UTP cable.
EN 3. Product features 3.1.
RS485 communication and power interface Warning LED The warning indicator LED flashes in case of failure of the connected charge controller. Audible alarm The audible failure alarm can be activated or deactivated. Communication LED Indicates communication status when the display is connected with the charge controller.
Charge current icon Day/night. PV- V & A. Battery status icons Battery icon EN 3.2. Display After connecting the remote panel, the default monitoring display will be shown: Load status icon Load current icon Battery-V&A Load-V&A Day and night icons , - Night - day. If the voltage of the solar array is above 1V, the daytime icon is shown. Battery icon The battery icon shows the state of charge of the battery. For this function the correct battery capacity must be set (see section 5.
Battery status icons - Normal voltage. , - Under voltage - Over discharge Load status icon - Load output “on” - load output “off” 3.3. Buttons Operation is visualized in the schematic diagram below: 4. Monitoring The default monitoring display and monitoring subpages can be accessed with the UP/DOWN and LEFT/RIGHT buttons. See the diagram on the next page.
EN 7
5. Full setup details 5.1. Main menu When in monitoring mode, the main menu is accessed by pressing the ESC button. The UP and DOWN buttons are used to browse through the main menu: 1 Monitoring 2 Device information 3 Test operation 4 Control parameters 5 Load set 6 Device parameters 7 Device password 8 Charge mode 9 Factory reset 10 Failure information 11 Meter parameters The OK and ESC buttons are respectively used to enter or exit the corresponding pages of the menu items.
EN The manual control function is disabled when other load output settings are chosen (see section 5.5). However, when other load output settings have been chosen, the load output can be tested (i.e. switched ON and OFF) after switching back to Manual Control. 5.4 Control Parameters The table below shows the list of battery related parameters that can be modified.
5.5 Load output setting The load output setting options are shown below: ◎Manual Control ◎Light On/Off ◎Light On+Timer Manual Control Default ON ◎Manual Control ◎Light On/Off ◎Light On+Timer ◎Time Control Light On/Off On: 0.5V DeT: 10M Off: 0.4V DeT: 10M ◎Manual Control ◎Light On/Off ◎Light On+Timer ◎Time Control Light On+Timer On: 0.5V DeT: 10M Off: 0.
Option 3: Light On+Timer This option allows for a pre-set On-time after dusk and a pre-set Off-time before dawn. The dusk and dawn switching moments and confirmation time are set as under option 2. The remaining parameters are set as follows: • NightTime: initial setting of the night duration, the controller will subsequently adjust NightTime to the actual duration of the night. • On Time 1: On period after dusk. • On Time 2: On period before dawn.
Option 4: Time control This option uses the internal clock (see section 5.6) to set one (Time1 only) or two on-time periods. 5.6 Device Parameters The first screen displays the software version and communication ID number of the Charge Controller. The second screen allows setting of the backlight timer, and local date & time (use the DOWN button to go to the second screen). The above data are stored in the Charge Controller. Device Parameter Ver: VX.
EN 5.10 Failure Information Displays failures such as Over Voltage, Over Load or Short Circuit. (automatic reset when the fault is corrected). 5.11 Parameters The first screen displays the type, software version and serial number of the remote meter. The second screen allows modification of • Switch-Pages (refresh time interval of the monitoring pages, default 0 seconds) • Backlight duration (default 20 seconds). • Audible alarm ON/OFF (default OFF).
8 Dimensions: 14
Victron Energy Blue Power Distributor: Serial number: Serial number: Version : 02 Date : 01 September 2014 Victron Energy B.V. De Paal 35 | 1351 JG Almere PO Box 50016 | 1305 AA Almere | The Netherlands General phone Customer support desk Fax : +31 (0)36 535 97 00 : +31 (0)36 535 97 03 : +31 (0)36 535 97 40 E-mail : sales@victronenergy.com www.victronenergy.