TR2526+ 2.5 - 2.
Document Name: TR2526+ Broadband Wireless Transceiver Installation and Operation Guide - r02 Approval: G.V. Document ID: MLTR2526+-02 Last modified: 23 September 2011 © Vecima Networks Inc. Vecima® is a registered trademark of Vecima Networks Inc. All Rights Reserved. Permission to Reproduce Except as otherwise specifically noted, the information in this publication may be reproduced, in part or in whole and by any means, without charge or further permission from Vecima Networks Inc.
Contents Preface ............................................................................................................................ ii About this Document ..................................................................................................................ii Safety Precautions ....................................................................................................................iv Getting Support ............................................................................
This page intentionally left blank
Preface Thank you for purchasing this product from Vecima Vecima Networks designs, manufactures and sells products that enable broadband access to cable, wireless and telephony networks. Vecima’s hardware products incorporate original embedded software to meet the complex requirements of next-generation, high-speed digital networks.
Preface This Installation and Operation Guide introduces TR2526+ and describes how it works. It is intended for engineers and technicians who are responsible for provisioning and maintaining TR2526+ and are familiar with wireless products and technology. Note: The information contained in this manual is subject to change without notice. About this Document The major sections of this manual are as follows: ii • Chapter 1—Provides general information on the TR2526+ Broadband Wireless Transceiver.
Document Conventions This manual uses the following special formats to emphasize key information. Be aware of all warnings and cautions before you begin to use TR2526+. WARNING! Whenever you see this icon and heading, the associated text addresses or discusses a critical safety or regulatory issue. CAUTION: Whenever you see this icon and heading, the associated text discusses an issue which could result in damage or abuse of the equipment. Carefully read and follow these instructions.
Safety Precautions Read and follow the following safety instructions before installing or operating a TR2526+ device. WARNING! Do not work on the system or connect or disconnect cables during periods of lightning activity. Ne pas travailler sur le système ni brancher ou débrancher les câbles pendant un orage du foudre. WARNING! Before installing and operating this equipment, read all safety, installation and operating sections. Retain this manual for future reference.
Getting Support All Vecima products include 90 days of basic technical support at no charge. We encourage you to contact us then to ensure your Vecima equipment is utilized to its fullest potential. We Support You... By Phone: You may contact our Wireless Applications Engineering Support (WAES) group directly by phone at 306-955-7075 and follow the prompts for wireless product support. By Email: For non-urgent matters and information requests, you may reach our support group by e-mail at support@vecima.
Warranty and Service Policies Warranty Statement Vecima Networks warrants its products to be free from defects in workmanship or materials for a period of two years. The warranty begins on the date of the original shipment from Vecima Networks to its customer. No claim may be allowed for expenses incurred in installation or use. No other expressed or implied warranties shall apply to the goods sold.
Step 4 Ship the product to Vecima Networks. The repair center will provide the customer with shipping instructions when they send the customer the RMA number. Ship each product to Vecima Networks in its original shipping container (or equivalent) via prepaid carrier, with appropriate insurance and customs documentation (where required). Clearly mark the RMA number on the outside of each package returned.
Warranty Coverage of Items Returned for Repair Vecima Networks will replace or repair returned items. After repairing the items, Vecima will test them to ensure that they are fully functional. Repair turnaround time is typically 20-30 business days after receipt of the item at Vecima Networks. Repaired items have a 90-day warranty from the date of return. This warranty only applies to problems related to the originally reported fault. Unrelated problems will be subject to a flat rate repair charge.
Chapter 1 Introduction 1.1 Functional Overview The Vecima Networks TR2526+ is an outdoor RF transceiver for use in wireless systems. The TR2526+ integrates an LNA, downconverter, upconverter, power amplifier, RF and IF duplexers to provide a one-box solution for wireless subscriber terminals. The TR2526+ is situated outdoors and connected to a cable modem indoors with standard RG-59 or RG-6 cable.
Module Features & Benefits This page intentionally left blank 2 TR2526+ Installation and Operation Guide - r02
Chapter 2 Installation This chapter explains how to mount and install a TR2526+ Broadband Wireless Transceiver. Before performing any of the procedures in this chapter, read all of the installation instructions to ensure that you understand all of the tool requirements and safety guidelines. 2.1 Unpacking the Unit Carefully remove the equipment from its packing material and set it on a solid surface, such as a table or desk.
Mounting the TR2526+ 2.2 Mounting the TR2526+ The TR2526+ was designed for mounting to a pole with a diameter of 1.0" to 1.75". Please ensure that the pole used is attached securely to the building or other mounting location. Mounting the Unit 1) Measure the required length of ground wire (not supplied) and crimp on a ring terminal (not supplied) to one end of the ground wire.
Mounting the Antenna Top View of TR2526+ Mounted on Pole Figure 2-3: Securing the TR2526+ to the pole 5) Place an #8 lock washer onto the #8-32 screw, followed by the ground wire / ring terminal from step 1, followed by a second #8 lock washer and thread this assembly into the ground attachment point provided and tighten. #8-32 Screw #8 Lock Washer Preassembled ring terminal / ground wire Ground attachment location Figure 2-4: Ground wire assembly and connection 2.
Connecting the Antenna Table 2.2 Antenna List Transceiver Power Antenna Type Watts dBm 0.200 23 Flat planar array 0.200 23 0.200 23 Antenna Gain EIRP Watts dBm 16 7.9 39 Dipole/parabolic reflector 21 25.1 44 Dipole /parabolic reflector 24 50.1 47 2.4 Connecting the Antenna Connect the TR2526+ to the antenna via the N-connector. After connection, the N connector must be waterproofed with the supplied rubber sealing tape. See “2.6 Water Proofing Connections” on page 8 for details.
Connecting the IF Cable 2.5 Connecting the IF Cable Connect one end of an RG-59 or RG-6 cable to the TR2526+ F-connector. After connection, the F connector must be waterproofed with the supplied rubber sealing tape. See “2.6 Water Proofing Connections” on page 8 for details. Vecima recommends F connectors should be tightened to a maximum torque of 30 in/lb. A 7/16" torque wrench should be used to prevent over tightening.
Water Proofing Connections 2.6 Water Proofing Connections Many transceiver problems can be attributed to environmental conditions (including vibration), which can loosen cables and permit moisture to penetrate the connectors. It is highly recommended to seal the connectors using a technique similar to the one described below. This will provide moisture protection and keep the connections tight.
Connecting the Power Inserter 2.7 Connecting the Power Inserter WARNING! Always unplug the power supply before making or changing connnections to the power inserter. CAUTION: The power inserter should be installed as near to the building entrance as possible. If this is not possible, then a grounding block for the transceiver cable must be installed at the service entrance.
Aligning the Antenna 2.8 Aligning the Antenna The TR2526+ is equipped with an audible alignment aid that simplifies the setup process. It permits alignment to the hub site without the use of the cable modem or any test equipment. It consists of a level detector for the full receive band and an audible beeper sealed into the unit that sounds at a rate that increases with increasing signal level. The detector operates over a wide signal level range.
Appendix A Specifications Feature Specification Transmit IF Input Frequency * 800 kHz Channel Width Center Frequency 1.6 MHz Channel Width Center Frequency 3.2 MHz Channel Width Center Frequency RF Output Frequency * 800 kHz Channel Width Center Frequency 1.6 MHz Channel Width Center Frequency 3.2 MHz Channel Width Center Frequency 14 - 42 MHz 14.5 – 41.5 MHz 14.9 – 41.1 MHz 15.7 – 40.3 MHz 2496 - 2524 MHz 2496.5 - 2523.5 MHz 2496.9 - 2523.1 MHz 2497.7 - 2522.
Feature Specification Modem Port IF Connector F female, 75 ohms IF Return Loss -10dB in transmit and receive bands IF Spurious Emissions -70dBm in 534 - 654 MHz band -35dBm from 5 - 860 MHz, excluding the receive band RF Port RF Connector N Female, 50 ohms RF Return Loss -8.
This page intentionally left blank
150 Cardinal Place Saskatoon, Saskatchewan, Canada S7L 6H7 Tel: (306) 955-7075 Fax: (306) 955-9919 Web: www.vecima.com Email: sales@vecima.