User Manual

1
PrecisionLine RCR-A/RCR-C
Description
PrecisionLine dual technology sensors combine range-controlled
radar (RCR) technology with a passive infrared (PIR) system to
increase false alarm immunity by allowing them to sense human-
sized objects within a specified range. Both the RCR and PIR
systems must be triggered to set off an alarm, unless in stealth mode
(radar-only).
The detector is designed to use a 12VDC power supply provided
by a UL Listed alarm control panel.
Features
The detector provides the following features:
Stealth Mode (radar only) - Internal jumper allows you to
disable the PIR, and use the radar only to detect intruders faster.
This mode can be used for covert installations (mounted behind
walls).
Selectable range up to 35 feet (10.7m) - Internal jumper
allows radar range selection to optimize coverage.
LED indicator - A multi-color LED provides detector status.
Tamper switch (RCR-C only) - Activated when the pins on the
circuit board are removed from the terminal sockets on the base.
Parts
The following parts are included with the detector:
RCR detector
1 screw to join the case halves
3 factory-installed jumpers
Selecting a Location for the Detector
The detector can be mounted in a corner or on a flat wall. Use the
following guidelines to determine the best location to install the
detector:
Mount the detector so the expected movement of an intruder is
across the detection pattern. See Figure 1.
Mount the detector on a stable surface 7 to 9 feet (2.1 to 2.7m)
high.
DO NOT mount the detector within 2 feet (0.6m) of any metallic
objects or within 5 feet (1.5m) of any florescent lights.
DO NOT place any objects in front of the detector that may
prevent a clear line of sight. Not applicable in High Security
Mode (radar only).
Avoid locations that expose the detector to possible false alarm
sources such as:
– Moving or vibrating objects (fans, pulleys, conveyor belts)
– Electronic fields (electric motors, high voltage equipment)
– Water spray or corrosive environments
– Heat sources in the field of view (heaters, radiators)
– Windows in the field of view
– Strong air drafts on the detector (fans, air conditioners)
When installing multiple detectors:
– DO NOT mount detectors facing each other.
– Mount them at least 20 feet (6.1m) apart.
– Use shorter range settings to avoid overlapping radar coverage.
– Mounting sensors back to back is not recommended, but if
an application requires such mounting, use the 9-foot (2.7m)
range, mount at least 1foot (0.3m) apart, and walk test the
installation to ensure proper operation.
SPR TMPR TMPR NO COM
Figure 2. Detector (exploded)
Figure 1. RCR and PIR Coverage Patterns
90°
Radar Viewing Area
PIR Viewing Area
Top View
Side View
35’
(10.7m)
35’
(10.7m)
27’
(8.2m)
27’
(8.2m)
18’
(5.5m)
18’
(5.5m)
9’
(2.7m)
9’
(2.7m)
0’
0’
35’
(10.7m)
27’
(8.2m)
18’
(5.5m)
9’
(2.7m)
6.9’
(2.1m)
PrecisionLine
Dual Technology Motion Sensor
Models: RCR-A (Form A)
RCR-C (Form C)
Installation Instructions